APC by Schneider Electric Galaxy VM System Bypass Cabinet 640KVA 380/400/415V EL - GVMSBC640KHEL

APC by Schneider Electric GVMSBC640KHEL Galaxy VM System Bypass Cabinet 640KVAOverviewThe APC by Schneider Electric GVMSBC640KHEL is a 640KVA three-ph…

$25,245.00 $17,171.99 SAVE $8073
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

APC by Schneider Electric Galaxy VM System Bypass Cabinet 640KVA 380/400/415V EL - GVMSBC640KHEL

$25,245.00
$17,171.99

Overview

SKU: GVMSBC640KHEL
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric GVMSBC640KHEL Galaxy VM System Bypass Cabinet 640KVA

Overview

The APC by Schneider Electric GVMSBC640KHEL is a 640KVA three-phase system bypass cabinet designed for the Galaxy VM UPS family, giving facilities teams a code-compliant manual bypass path without taking critical loads offline during UPS maintenance or servicing. If you're running a large data center, hospital plant room, or industrial facility on a Galaxy VM UPS and need a way to isolate the UPS for inspection or replacement without dropping power to the load — this is the dedicated hardware for that job. It operates on 380/400/415V three-phase input and output at 50/60 Hz, covers the full 640KVA capacity of the matching UPS tier, and is built in a steel enclosure rated for 0–40°C operating environments. For enterprise power and UPS infrastructure, a bypass cabinet is not optional — it's what separates a maintainable system from one that forces an outage every service interval.

Key Features

  • 640KVA Three-Phase Bypass Capacity: Matched to the Galaxy VM UPS at the 640KVA tier, this cabinet handles the full rated load without derating. Undersizing a bypass path creates a bottleneck that defeats the purpose — here, the bypass is rated on par with the UPS itself.
  • 380/400/415V Multi-Voltage Input and Output: Supports the three most common European and international three-phase distribution voltages, which means the same cabinet works across facilities with slightly different transformer tap settings. No custom rewiring needed when deploying across mixed-voltage sites.
  • 50/60 Hz Frequency Compatibility: Operates across both 50 Hz and 60 Hz mains, making the GVMSBC640KHEL deployable in North American and international facilities without frequency-specific hardware variants.
  • LCD Display with LED Indicators: Onboard LCD and LED status indicators give technicians immediate visibility into bypass state without needing to access a separate monitoring system. During a live bypass transition, local confirmation of switch state is a safety requirement — this satisfies it without an external panel.
  • Steel Enclosure: The steel housing provides the structural rigidity and electromagnetic shielding appropriate for high-current switchgear in a plant room or data hall. At 640KVA, bus bar connections and switching contacts generate significant electromagnetic fields — a steel cabinet contains them.
  • 0–40°C Operating Temperature Range: Covers standard data center and plant room thermal envelopes. If your mechanical cooling targets 18–27°C and has headroom to 40°C on a cooling failure, this cabinet stays within spec. The storage range extends to -25–65°C, which matters for long-term staging in unheated warehouses.
  • 0–95% Non-Condensing Humidity Tolerance: The same operating and storage humidity envelope (0–95%) means no derating in humid climates or coastal facilities, provided condensation is controlled at commissioning.
  • Operating Altitude up to 1,000m: Rated to 1,000m above sea level for full performance. Sites above that threshold — Denver, high-altitude industrial facilities, mountain data centers — need to verify derating with APC engineering before specifying this unit.
  • RoHS Compliance: Meets RoHS directive requirements, which is a procurement prerequisite for EU public-sector and many enterprise frameworks. Confirms restricted hazardous substance compliance across the assembly.
  • 712mm Width × 859mm Depth Footprint: Compact relative to 640KVA capacity, though you'll need accurate floor plan measurements before ordering. The depth of 859mm requires clearance behind the cabinet for cable management and rear access — budget at minimum 1m clear zone at the rear in your plant room layout.

Integration and Compatibility

The GVMSBC640KHEL is engineered for the APC by Schneider Electric Galaxy VM UPS series at the 640KVA rating. System bypass cabinets in this class are not universal switchgear — they are model-matched components. Verify your Galaxy VM UPS model and kVA rating before ordering; a 500KVA or 800KVA unit will require a different bypass cabinet. Three-phase installations of this scale also require qualified electrical contractors for commissioning; this is not field-installed by general AV or IT integrators. The cabinet's 400V input aligns with standard European low-voltage distribution (TN-S and TN-C-S systems), and the three-phase configuration requires a balanced three-phase supply. Coordinate with your three-phase UPS design and your facility's electrical engineer to confirm bus ratings, cable sizing, and protective device coordination upstream of this cabinet. For facilities running data center infrastructure at scale, a bypass cabinet is part of the commissioning and maintenance plan from day one — retro-fitting it later means a planned outage that could have been avoided.

Frequently Asked Questions

Q: What UPS model is the GVMSBC640KHEL designed to work with?

A: The GVMSBC640KHEL is designed for the APC Galaxy VM UPS series at the 640KVA capacity tier. It is a model-matched bypass cabinet — confirm your specific Galaxy VM model and kVA rating before ordering to ensure compatibility.

Q: What input voltage does the GVMSBC640KHEL support?

A: The cabinet supports 380V, 400V, and 415V three-phase input at 50 or 60 Hz, covering the primary European and international low-voltage distribution standards.

Q: What is the operating temperature range of the GVMSBC640KHEL?

A: The operating temperature range is 0°C to 40°C. Storage temperature extends from -25°C to 65°C, which covers unheated warehouse staging environments.

Q: Is the GVMSBC640KHEL RoHS compliant?

A: Yes, the GVMSBC640KHEL carries RoHS compliance certification, meeting EU restricted hazardous substance requirements — a common procurement requirement for European public-sector and enterprise buyers.

Q: What are the physical dimensions of the GVMSBC640KHEL?

A: Width is 712mm and depth is 859mm. Height data is not available in current evidence — contact the manufacturer or your electrical contractor for full dimensional drawings before planning floor space allocation.

Q: Does the GVMSBC640KHEL include a display?

A: Yes, the cabinet includes a built-in LCD display and LED indicators for local status monitoring of bypass state during maintenance transitions.

Jerry Tildsen
Jerry Tildsen

The GVMSBC640KHEL is a maintenance bypass cabinet that gets overlooked during Galaxy VM procurement and becomes a crisis when it's missing. At 640KVA three-phase, you cannot perform UPS maintenance without either dropping the load or having a bypass path — and improvised bypass solutions at this power level are an electrical safety problem, not just an inconvenience. The fact that this unit includes an onboard LCD display means your team can confirm bypass state locally without relying on SNMP or a management card being online during the exact moment you need to pull the UPS.

Technical Highlights:

  • 640KVA Full-Rated Bypass: The bypass path is rated at the same 640KVA as the UPS it serves — no derating on the bypass side, which is what you need to sustain full data hall or critical load during a UPS servicing window.
  • Multi-Voltage Support (380/400/415V): Three-phase distribution voltage tolerance across 380–415V means a single cabinet SKU covers facilities with different transformer configurations, reducing the part number complexity in multi-site deployments across Europe or international campuses.
  • Operating Envelope 0–40°C / 0–95% RH: Standard plant room conditions, but note the 0°C lower bound — the cabinet is not rated for operation in unheated spaces during winter commissioning. Stage it in a conditioned environment before energizing.

Deployment Considerations:

  • The 859mm depth requires a rear clear zone of at least 1 meter in plant room layouts; confirm this against your existing cable tray and busway routing before the cabinet arrives on site, not after.
  • The operating altitude ceiling is 1,000m — facilities above this threshold (high-altitude industrial sites, mountain campuses) must obtain manufacturer derating guidance before specifying the GVMSBC640KHEL at full 640KVA load.

This cabinet belongs in any Galaxy VM 640KVA deployment where planned maintenance intervals, regulatory compliance, or uptime SLAs make dropping the critical load an unacceptable service event — specifically data centers, hospital power plants, and industrial automation facilities running continuous processes.

Specifications
Product colour: White
LED indicators: Yes
Housing material: Steel
Built-in display: Yes
Display type: LCD
Input voltage: 400 V
Input frequency: 50/60 Hz
Output voltage: 400 V
Number of phases: 3
Compliance certificates: RoHS
Operating temperature (T-T: 0 - 40 °C
Storage temperature (T-T: -25 - 65 °C
Operating relative humidity (H-H: 0 - 95%
Storage relative humidity (H-H: 0 - 95%
Operating altitude: 0 - 1000 m
Non-operating altitude: 0 - 14763 m
Width: 712 mm
Depth: 859 mm
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources