APC by Schneider Electric
SKU: GVSBPOT50B
Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The GVSBPOT100 is a freestanding maintenance bypass cabinet purpose-built for the APC Galaxy VS UPS platform, covering 60–100KW loads at 480V input. Its integrated step-down output transformer converts the 480V supply to 208V output — eliminating the need for a separate transformer enclosure in data centers or industrial facilities where the distribution infrastructure runs at 480V but critical loads (servers, network gear, automation equipment) require 208V. This is the right cabinet when you need bypass capability and voltage transformation in a single, code-compliant footprint.
At 600mm wide × 836mm deep × 1485mm tall, the GVSBPOT100 fits in standard power and UPS infrastructure rows without requiring a custom bay. The white freestanding enclosure installs alongside the Galaxy VS UPS frame, and the integrated bypass path means UPS maintenance or replacement can be performed without dropping protected loads — critical in 24/7 operations where any unplanned downtime has direct business impact.
The GVSBPOT100 is designed for use with the APC Galaxy VS UPS platform in the 60–100KW range. The 480V input aligns with North American commercial distribution at the 480V/277V level, and the 208V output feeds standard IT and commercial load panels. When specifying this cabinet, confirm the Galaxy VS UPS frame rating matches the 60–100KW window — the bypass cabinet must be rated at or above the connected UPS output to avoid a capacity mismatch at the bypass path.
Physical installation requires coordination with the facility's electrical contractor: 480V input terminations, output wiring to the load panel, and the Galaxy VS interconnect must all be sized and terminated per the installation guide. The 675kg shipping weight (package dimensions 990 × 800 × 1670mm) means rigging and floor-loading calculations should be completed before the unit arrives on site. Confirm the raised floor or concrete slab load rating accommodates the installed weight of the cabinet plus any conduit and cable management overhead.
Q: What UPS platform is the GVSBPOT100 designed to work with?
A: The GVSBPOT100 is designed for the APC Galaxy VS UPS platform, covering the 60–100KW capacity range. It provides a maintenance bypass path so the Galaxy VS can be serviced or replaced without dropping protected loads.
Q: What voltage conversion does the built-in transformer provide?
A: The integrated output transformer steps down 480V input to 208V output. This is useful in facilities where the distribution infrastructure runs at 480V but the connected IT or commercial loads require 208V — eliminating the need for a separate external transformer enclosure.
Q: What are the physical dimensions of the GVSBPOT100?
A: The cabinet measures 600mm wide × 836mm deep × 1485mm tall. The shipping package is 990mm wide × 800mm deep × 1670mm tall, and the packaged weight is 675kg — rigging and floor-load planning are required before delivery.
Q: Is the GVSBPOT100 RoHS and REACH compliant?
A: Yes. The GVSBPOT100 carries both RoHS and REACH compliance certifications, which restrict hazardous substances and address chemical safety under EU regulations. These certifications are commonly required by enterprise, government, and healthcare procurement programs.
Q: What are the operating environment requirements for the GVSBPOT100?
A: The cabinet is rated for 0–40°C operating temperature and 0–95% relative humidity (non-condensing). Storage ratings extend to -25–55°C and 0–95% RH. It is a freestanding unit intended for installation in controlled indoor environments such as data centers, equipment rooms, and industrial facilities.
Q: Can the GVSBPOT100 be used as a standalone bypass without the Galaxy VS UPS?
A: No. The GVSBPOT100 is a bypass cabinet accessory designed to work in conjunction with the Galaxy VS UPS platform. It does not function as a standalone power conditioning or UPS device.

The GVSBPOT100 solves a specific and common infrastructure problem: facilities fed at 480V that need to protect 208V loads with a Galaxy VS UPS. The integrated step-down transformer is what separates this cabinet from a standard bypass — instead of coordinating a separate transformer enclosure, an electrician, and additional floor space, you get a single freestanding footprint at 600 × 836 × 1485mm that handles both bypass switching and voltage conversion. That matters when you're tight on row space in a data center or working within a fixed mechanical room layout.
Technical Highlights:
Deployment Considerations:
The GVSBPOT100 is the right specification for a greenfield data center or critical manufacturing facility where the building distribution runs at 480V, the critical load infrastructure is 208V, and the Galaxy VS is already on the single-line. It's not a general-purpose bypass cabinet — it's purpose-built for that 480V-to-208V Galaxy VS deployment scenario.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more APC by Schneider Electric products? Shop the full APC by Schneider Electric catalog →
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price