Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: XG84522BS00A4
Condition: New
Availability: Usually Ships in 2-3 Weeks
Write a Review 31% OFF

Panduit XG84522BS00A4 45RU 800mm FlexFusion Cabinet

Panduit XG84522BS00A4 FlexFusion 800mm 45RU Network Cabinet The Panduit XG84522BS00A4 delivers a purpose-built 45RU enclosure for high-density data ce…

$13,186.63 $9,133.99 SAVE $4053

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Panduit XG84522BS00A4 45RU 800mm FlexFusion Cabinet

$13,186.63
$9,133.99

Overview

SKU: XG84522BS00A4
Condition: New
Availability: Usually Ships in 2-3 Weeks

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit XG84522BS00A4 FlexFusion 800mm 45RU Network Cabinet

The Panduit XG84522BS00A4 delivers a purpose-built 45RU enclosure for high-density data center and telecommunications installations where thermal management and equipment access drive uptime. This FlexFusion cabinet combines 800mm width with 1200mm depth to accommodate deep switches, UPS systems, and cable management arms without rear-door interference. The integrated top cap with brush seal creates a continuous hot-aisle containment barrier when deployed in row configurations, while dual PDU mounting brackets position power distribution where horizontal space is constrained. Built for installers managing multi-vendor racks in colocation or enterprise server rooms, this cabinet addresses the gap between standard 600mm-deep enclosures that block airflow and oversized frames that waste floor space.

Key Features

  • 45RU vertical mounting space accommodates full-height blade chassis, patch panels, and 1U/2U appliances with room for overhead cable routing
  • 800mm x 1200mm footprint (31.5" x 47.2") fits standard data center tile layouts while providing depth for rear-mounted PDUs and horizontal cable managers
  • 3,000 lb static load capacity and 2,250 lb dynamic rating handle fully-loaded configurations with redundant power supplies, battery backups, and dense copper or fiber distribution
  • Top cap with brush seal blocks rising heat from contaminating cold-aisle supply air in contained environments—eliminates the cardboard-and-tape fixes common with open-top racks
  • Dual PDU bracket system (left and right) supports vertical zero-U power strips without consuming EIA-310 rail space—keeps outlets accessible when U-space is sold out
  • Steel construction with black finish resists corrosion in humidity-controlled environments and maintains ground continuity across bonding points
  • EIA-310-E and IEC 60297 compliance ensures global compatibility with 19" rackmount equipment from any vendor—no adapter rails or custom drilling
  • UL 2416 listing validates structural integrity and electrical safety for installations subject to building-code inspection or insurance underwriting

The 1200mm depth solves the cable-pinch problem that surfaces when installing enterprise switches with rear-facing SFP+ ports or redundant power supplies. Standard 600mm enclosures force integrators to choose between door removal (breaking containment) or cable-bend violations that fail TIA-568 pull-tension limits. This cabinet's 47.2" depth leaves 8–10 inches of rear clearance after mounting a 30"-deep switch, enough for service loops on DAC cables or LC duplex patch cords without kinking. The top cap's brush seal accommodates cable egress to overhead ladder rack while maintaining differential pressure across the hot aisle—critical when CRAC units depend on predictable return-air temperature. Installers working under ASHRAE thermal guidelines will find the brush fingers compress around cable bundles up to 2" diameter without creating bypass gaps that short-circuit containment.

The dual PDU bracket design reflects real-world power distribution in A/B feed environments. Left and right mounting positions let you run diverse circuits from separate UPS systems or utility panels, so a single-feed failure doesn't black out the rack. Brackets attach to the cabinet's vertical frame without consuming 19" rail space, leaving all 45U available for IT equipment. This zero-U approach matters in colocation facilities where monthly recurring cost scales with consumed rack units—every U you surrender to a center-mount PDU is revenue you're not capturing. The bracket system accommodates metered, switched, or basic PDUs from APC, Raritan, Server Technology, or Panduit's own managed strips, giving procurement flexibility when lead times or budget shift mid-project.

Steel construction with powder-coat black finish handles the mechanical stresses of repeated equipment installs and the environmental conditions of HVAC-controlled spaces. The 2,250 lb dynamic rating accounts for rolling loads during maintenance windows when you're sliding server rails in and out under live power—critical in 24/7 environments where scheduled downtime doesn't exist. The 3,000 lb static capacity supports fully-populated blade chassis or storage arrays that exceed the 1,500 lb limits of residential-grade racks sold into adjacent markets. Load distribution across the cabinet's frame prevents the front-heavy sag common when mounting pizza-box servers without rear support, maintaining door alignment and latch function over the 10–15 year service life typical in enterprise data centers.

EIA-310-E and IEC 60297 compliance ensures the cabinet's 19" rail spacing and square/round hole patterns match global standards, so equipment from US, European, or Asian vendors mounts without modification. UL 2416 listing covers structural performance, grounding integrity, and flammability—required for installations subject to local electrical codes or facilities with stringent insurance underwriting. For integrators managing multi-site rollouts across jurisdictions, these certifications streamline permit approval and final inspection. The FlexFusion cabinet ships fully assembled with reversible doors and tool-less side panels, cutting installation time when you're racing a forklift schedule or a maintenance window that closes at 06:00.

Specifications
Product Type: Network Cabinet
Sub-Brand: FlexFusion
Height: 45RU
Width: 31.5 in (800 mm)
Depth: 47.2 in (1200 mm)
Material: Steel
Color: Black
Static Load Capacity: 3,000 lbs (1,361 kg)
Dynamic Load Capacity: 2,250 lbs (1,021 kg)
Top Panel: Top Cap with Brush Seal
PDU Mounting: Dual Brackets (Left and Right)
Standards Met: EIA-310-E, IEC 60297, UL 2416
Mounting Standard: 19" EIA-310-E Rack
Application: Data centers, server rooms, telecommunications spaces
Thermal Management: Hot-aisle containment with brush seal
Finish: Powder-coated black
Assembly: Fully assembled
Door Configuration: Reversible
Side Panels: Tool-less removal
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources