Panduit
SKU: XG84522BS000L
Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Panduit XG84519BS003U is a 45RU FlexFusion steel network cabinet engineered for high-density equipment deployments in enterprise data centers, colocation facilities, and telecommunications spaces. Built to support 2,250 lbs dynamic load capacity and 3,000 lbs static, this cabinet handles fully-loaded server configurations, network switches, UPS systems, and patch panels without structural compromise. The FlexFusion platform integrates optimized airflow management with modular cable routing — critical for thermal efficiency in racks running 10/25/40/100GbE switching fabrics or dense compute nodes.
The XG84519BS003U measures approximately 800mm width (31.5") by 1070mm depth (42.1") — a mid-depth profile that accommodates standard enterprise servers (28-30" depth) while leaving rear clearance for power cables, management NICs, and redundant PSU connections. The 45RU height provides enough vertical space for a typical deployment of (2) 2U compute nodes, (1) 1U top-of-rack switch, (1) 2U storage array, (1) 1U KVM, and (1) 2U UPS with room for future expansion — or alternatively a full blade chassis with integrated switching and management modules.
Steel construction is specified over aluminum for installations where electromagnetic shielding, vibration damping, and long-term structural integrity outweigh weight considerations. The welded frame resists racking (diagonal distortion) under asymmetric loads — common when mounting heavy UPS batteries in the lower RU positions and lightweight patch panels at eye level. Corner posts are tapped for both square-hole and round-hole mounting hardware; standard 12-24 or M6 cage nuts install without tools. Vertical rails include RU markings every 5 units for fast equipment positioning during staged deployments.
Long-finger cable managers are factory-installed on both vertical rails. The extended finger depth (typically 4-6" beyond the rail face) creates a dedicated routing channel for high-pair-count copper bundles and multi-fiber trunk cables (MPO/MTP breakouts, LC duplex arrays, SC/ST legacy links). This keeps structured cabling separate from equipment air intake zones — preventing recirculated exhaust from being drawn into server fans. Fingers use a flexible plastic construction that bends to accommodate mid-rack entry points without snapping under tension. Integrators running 10GBASE-T or 25G/40G/100G fiber to every server can route cables vertically to a top-of-rack switch, then horizontally through the finger channels to each RU without crossing airflow paths.
The caster base is a field-removable option; installations on raised floors typically retain casters for mobility during MAC (move/add/change) operations, while slab-floor or seismic-rated deployments may replace casters with adjustable leveling feet or anchor brackets. Casters lock in both swivel and roll directions — necessary when technicians are torquing rack-mount screws or pulling equipment from rails. The caster mounting plate is reinforced to distribute the 3,000 lb static load across the entire floor contact area, preventing point-loading damage to raised floor tiles (which are typically rated for 1,000-2,000 lbs per tile).
FlexFusion's thermal design assumes front-to-rear airflow with perforated front doors (typically 60-70% open area) and solid or perforated rear doors depending on containment strategy. In cold-aisle containment, rear doors are often removed or replaced with brush strips to allow unrestricted hot exhaust into the contained hot aisle. In open-environment deployments without containment, perforated rear doors improve aesthetics and physical security while maintaining >80% airflow transparency. Side panels are removable without tools for quick access during troubleshooting — a requirement in 24/7 operations where rack-level failures must be isolated in under 15 minutes.
Compliance with EIA-310-E ensures mounting-hole spacing matches every manufacturer's rail kit and bracket system — Dell, HPE, Cisco, Juniper, Supermicro, and whitebox vendors all publish EIA-310-E as the reference standard. IEC 60297 alignment covers international deployments in EMEA and APAC regions where local electrical codes reference IEC rather than NEMA/ANSI standards. UL 2416 certification (rack-mounted equipment) and seismic qualification per GR-63-CORE Zone 4 make this cabinet suitable for carrier-grade telecom central offices, hyperscale cloud provider edge sites, and financial services data centers with strict uptime SLAs.
The XG84519BS003U ships as a complete assembly with pre-installed vertical rails, front and rear doors, side panels, and caster base. Integrators should plan for a two-person installation due to the cabinet's unladen weight (typically 300-400 lbs for steel frames of this size) and the need to maneuver through standard 36" doorways and freight elevators. Once positioned, the cabinet accepts standard PDU mounting (vertical zero-U PDUs bolt to the rear vertical rails or side walls), environmental monitoring sensors (temperature/humidity probes mount via included cable pass-throughs), and KVM drawer rails.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Panduit products? Shop the full Panduit catalog →
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price