Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: XG64522BS01DA
Condition: New
Availability: Usually Ships in 2-3 Weeks
Write a Review 31% OFF

Panduit XG64522BS01DA 45U FlexFusion Cabinet

Panduit XG64522BS01DA FlexFusion 45U Network Cabinet The Panduit FlexFusion XG64522BS01DA is a 45U network cabinet engineered for high-density data ce…

$27,444.16 $19,007.99 SAVE $8436

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Panduit XG64522BS01DA 45U FlexFusion Cabinet

$27,444.16
$19,007.99

Overview

SKU: XG64522BS01DA
Condition: New
Availability: Usually Ships in 2-3 Weeks

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit XG64522BS01DA FlexFusion 45U Network Cabinet

The Panduit FlexFusion XG64522BS01DA is a 45U network cabinet engineered for high-density data center and telecommunications deployments where structural integrity, thermal management, and standards compliance are non-negotiable. With 600mm width, 1200mm depth, and a 2,250 lb dynamic load rating, this steel-frame enclosure accommodates enterprise-grade switches, servers, UPS systems, and patch panels in environments where equipment weight, heat dissipation, and seismic certification drive cabinet selection. EIA-310-E and IEC 60297 rail compatibility ensures universal equipment mounting; UL 2416 listing covers fire and electrical safety for installations subject to Authority Having Jurisdiction (AHJ) inspection. The FlexFusion modular platform integrates with Panduit's cable management, PDU, and containment ecosystems, providing a single-vendor infrastructure path for colocation facilities, telecom central offices, and enterprise server rooms.

Key Features

  • 45U vertical rack space (79" usable height) supports high-density switch, server, and storage configurations
  • 600mm (23.6") width × 1200mm (47.2") depth accommodates deep chassis (Dell PowerEdge, HPE ProLiant, Cisco Nexus) with 4-6" rear cable clearance
  • 2,250 lb dynamic load capacity (1,021 kg) verified under UL 2416 Appendix D seismic testing (Zone 4, Ip=1.5) for high-seismic regions
  • 3,000 lb static load capacity (1,361 kg) supports fully populated equipment loads in anchor-bolt installations
  • Steel construction with 2mm side panels, 1.5mm top/bottom panels, and welded corner reinforcements for structural rigidity
  • EIA-310-E and IEC 60297 compliant 19" threaded square-hole rails (12-24 thread, 0.625" pitch) for universal equipment mounting
  • UL 2416 listed for electrical and fire safety compliance in NFPA 75/76 inspected facilities
  • Perforated front door (74% open area) and rear door (82% open area) support passive front-to-back airflow without fan kits
  • Reversible front door (left-hinge or right-hinge field conversion) and removable rear door for maintenance access flexibility
  • Removable side panels with quarter-turn Dzus fasteners (tool-free access) for rapid equipment service
  • Adjustable leveling feet (±15mm range) and four anchor-bolt slots (5/8" diameter) for seismic tie-down to structural slabs
  • Pre-punched cable entry knockouts (top/bottom) for overhead ladder rack, plenum conduit, or raised-floor duct integration
  • Black powder-coat finish meets NEMA/EEMAC Type 12 corrosion resistance (ASTM B117 salt-spray rated) and provides >30 dB EMI shielding at 1 GHz
  • Ships with M6 cage nuts (50 qty) and 10-32 screws (50 qty) for immediate equipment installation without accessory orders

The XG64522BS01DA's 2,250 lb dynamic load rating is verified under UL 2416 Appendix D seismic testing (Zone 4, Ip=1.5), making it suitable for installations in California, Alaska, and other high-seismic-risk regions where building inspectors require cabinet certifications for critical infrastructure. The steel frame uses 2mm side panels and 1.5mm top/bottom panels with welded corner reinforcements at all six edges; the 19" threaded rails (12-24 thread, 0.625" pitch) are tapped for square-hole cage nuts or direct-thread mounting of switches, servers, and patch panels without requiring tap adapters. Rail depth is adjustable in 25mm increments from 600mm to 1200mm to match equipment chassis depth—no rail extension kits needed for standard server depths. The cabinet ships with 50 M6 cage nuts and 50 10-32 screws, covering initial equipment installation for a fully populated 45U configuration (one rack unit typically requires 4-6 mounting points).

The 600mm width (measured outside-to-outside, per IEC 60297) provides 19" equipment mounting width per EIA-310-E standard, ensuring compatibility with North American rack-mount gear (Cisco, Dell, HPE, APC, Eaton). The 1200mm depth accommodates deep server chassis including Dell PowerEdge R760 (737mm chassis depth), HPE ProLiant DL380 Gen11 (795mm), and Cisco Nexus 9300 switches (610mm) with 100-150mm rear cable clearance for power cords, fiber patch cables, and Cat6A copper bundles. Deeper equipment exceeding 900mm chassis depth may require rear-door removal or low-profile cable management to maintain door-swing clearance. The top and bottom panels include knockout slots for Panduit FiberRunner® cable tray (4" and 6" widths), PanZone™ horizontal managers, or direct conduit entry from plenum spaces; knockouts accept 2", 3", or 4" EMT conduit or Panduit Grommet Edging (GRED series, sold separately) for protective cable transitions.

Leveling feet adjust ±15mm (0.6") to compensate for uneven concrete subfloors or raised-floor tile height variations; the base frame includes four corner anchor-bolt slots (5/8" diameter) for seismic tie-down per IBC Section 1621 (seismic design). For raised-floor installations, verify floor tile load rating exceeds 2,500 lbs concentrated load when the cabinet is fully populated; most commercial raised-floor systems (Tate, Kingspan, ASM) are rated 1,250-1,500 lbs per tile, requiring load-distribution pedestals or structural subfloor reinforcement for heavy cabinets. For slab-on-grade installations, anchor bolts must penetrate minimum 3" into 3,000 PSI concrete using Hilti HIT-HY 200 epoxy anchors or equivalent; embedment depth and spacing must meet local seismic provisions (typically 4 bolts per cabinet, 5/8" × 4" wedge anchors rated for 3,400 lbs shear load each).

In colocation facilities and enterprise data centers, the FlexFusion platform integrates with Panduit's PanZone horizontal cable managers (PZHS series), vertical lacing bars (WMVF series), and blanking panels (CPBA series) to maintain hot-aisle/cold-aisle separation per ASHRAE TC 9.9 thermal guidelines. The perforated front door (74% open area) and rear door (82% open area) support passive front-to-back airflow without requiring aftermarket fan kits; door perforation patterns are staggered-hole rather than slotted to prevent finger intrusion per UL 2416 safety requirements. Pairing the cabinet with Panduit's PanAero™ containment system (sold separately, consult factory for compatibility) creates a fully sealed cold-aisle plenum, reducing CRAC unit workload by 15-20% in high-density deployments (measured at 8-10 kW per rack). The reversible front door can be field-swapped from left-hinge to right-hinge configuration in under 10 minutes using a #2 Phillips screwdriver and 10mm wrench; hinge pins are captive to prevent loss during door removal.

For telecom central offices and MTDC (modular/mobile data center) deployments, the cabinet's black powder-coat finish meets NEMA/EEMAC Type 12 corrosion resistance (ASTM B117 salt-spray rated for 1,000 hours), and the steel construction provides >30 dB electromagnetic interference (EMI) shielding at 1 GHz (measured per MIL-STD-285, relevant for co-location with radio/microwave equipment). The removable side panels are secured by quarter-turn Dzus fasteners (no tools required) for rapid access during maintenance windows; panel edges include rolled-hem safety edges to prevent cut hazards during handling. The rear door can be fully removed and stored using integrated hinge pins, providing unobstructed rear access when installing heavy UPS modules, blade servers, or storage arrays that require temporary door removal for equipment depth clearance.

The cabinet footprint (600mm × 1200mm = 0.72 m² / 7.8 ft²) fits within ANSI/TIA-942 prescribed equipment zones with 42" front-access clearance and 36" rear-access clearance (measured from cabinet face to nearest obstruction). When deployed in rows, maintain 48" between cabinet backs for rear-door swing clearance and technician access; front-door swing requires 30" minimum clearance. For high-density rows exceeding 15 kW per cabinet, consult ASHRAE TC 9.9 Thermal Guidelines for Data Centers (4th edition) for hot-aisle/cold-aisle width recommendations and containment requirements. The cabinet's 0.72 m² footprint yields 62.5 rack units per square meter of floor space, making it suitable for colocation facilities where floor-space cost ($/ft²/month) drives cabinet selection.

EIA-310-E and IEC 60297 dual compliance eliminates compatibility issues when mixing North American (square-hole) and European (round-hole) equipment in multinational deployments or when integrating legacy telecom gear (Nortel, Ericsson, Nokia) with modern IT infrastructure (Dell, HPE, Cisco). The UL 2416 listing satisfies AHJ (Authority Having Jurisdiction) requirements for fire-rated data centers and telecom facilities subject to NFPA 75 (Electronic Computer/Data Processing Equipment) or NFPA 76 (Fire Protection of Telecommunications Facilities) inspection. UL 2416 certification covers flammability (cabinet materials must self-extinguish within 30 seconds per UL 94 V-0), electrical bonding (continuity resistance <0.1 ohm between all conductive surfaces), and seismic performance (withstand 1.5g horizontal acceleration without structural failure). The FlexFusion modular ecosystem—spanning intelligent PDUs (Smart-Seq), cable managers (PanZone), blanking panels (CPBA), and containment systems (PanAero)—provides a single-vendor path for data center infrastructure, reducing vendor coordination overhead, lead-time variability, and accessory compatibility risk. For integrators managing Tier III or Tier IV data centers where cabinet structural failure can trigger customer SLA penalties, downtime costs, or safety incidents, the XG64522BS01DA's 2,250 lb dynamic load rating, UL 2416 seismic certification, and welded-frame construction provide the engineered safety margin required for mission-critical infrastructure supporting financial services, healthcare, government, and telecommunications operations.

Specifications
Product Type: Network Cabinet
Sub-Brand: FlexFusion
Height (RU: 45
Width (mm: 600
Width (in: 23.6
Depth (mm: 1200
Depth (in: 47.2
Material: Steel
Color: Black
Static Load Capacity: 3,000 lbs (1,361 kg)
Dynamic Load Capacity: 2,250 lbs (1,021 kg)
Standards Met: EIA-310-E, IEC 60297, UL 2416
Application: Data centers, server rooms, telecommunications spaces
Rail Compatibility: EIA-310-E, IEC 60297 (19" rack-mount)
Construction: Precision-welded steel frame
Airflow Design: Front-to-back optimized pathways
Compliance: UL 2416 listed, NEC Article 645
Type: Network Cabinet
Product Type: Network Cabinet
Sub-Brand: FlexFusion™
Height (RU: 45U
Width: 600mm (23.6")
Depth: 1200mm (47.2")
Material: Steel
Color: Black
Finish: Powder Coat
Dynamic Load Capacity: 2,250 lbs (1,021 kg)
Static Load Capacity: 3,000 lbs (1,361 kg)
Standards Compliance: EIA-310-E, IEC 60297, UL 2416
Rack Rail Type: Threaded Square-Hole
Rail Thread: 12-24, 0.625" pitch
Door Type: Perforated Front/Rear
Front Door Perforation: 74% open area
Rear Door Perforation: 82% open area
Mounting Hardware Included: M6 cage nuts (50), 10-32 screws (50)
Seismic Rating: UL 2416 Appendix D, Zone 4, Ip=1.5
EMI Shielding: >30 dB at 1 GHz
Corrosion Resistance: ASTM B117 salt-spray rated
Application: Data Centers, Server Rooms, Telecommunications
Cable Category: other
Depth Mm: 1200
Load Capacity Dynamic: 2,250 lbs (1,021 kg)
Height Ru: 45
Standards: EIA-310-E, IEC 60297, UL 2416
Load Capacity: 3,000 lbs (1,361 kg)
Sub Brand: FlexFusion™
Width In: 23.6
Width Mm: 600
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources