Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit FHDEC2X2LYL FiberRunner 2x2 End Cap

Overview

The Panduit FHDEC2X2LYL is a press-fit end cap designed specifically for the Panduit FiberRunner 2x2 fiber routing channel system. It closes off open channel ends and fittings — a small detail that matters when your data center's fiber routing infrastructure needs to look finished and protect cable entry points from accidental snagging or debris ingress. Installation is tool-free: the cap presses directly into the channel opening with no coupler required. Sold individually (package quantity: 1), with carton quantities of 5 for larger deployments.

Key Features

  • Press-Fit Installation, No Coupler Required: The FHDEC2X2LYL snaps into open channel ends by hand. No hardware, no coupler, no tools — cuts termination time to seconds per run, which adds up fast across a fully cabled data center floor.
  • Polycarbonate/ABS Construction: The material combination delivers impact resistance from the ABS blend and temperature stability from the polycarbonate — appropriate for data center and central office environments where equipment density creates localized heat pockets.
  • RoHS Compliant: Meets RoHS requirements out of the box, keeping your structured cabling installation aligned with environmental compliance requirements without additional documentation overhead.
  • UL-Listed Optical Cable Routing Assemblies (to 2024A): Carrying UL certification through the 2024A standard means the FiberRunner assembly — with this cap installed — satisfies the fire and safety listing that inspectors look for in commercial and enterprise builds.
  • Telcordia GR-63-CORE and NEBS Level 3 Compliant: These standards govern seismic and environmental performance for network equipment installations. If you're deploying in a carrier hotel, central office, or any facility subject to NEBS requirements, this end cap doesn't break your compliance posture.
  • Compact Footprint: At 2.37 in. wide × 2.14 in. tall × 0.58 in. deep (60.2 mm × 54.4 mm), the cap sits flush within the channel profile without extending into adjacent cable trays or overhead pathways.
  • Yellow Color Coding: The yellow finish matches the FiberRunner 2x2 channel system's standard color designation, maintaining visual consistency across your fiber routing infrastructure — useful when tracing runs or auditing during adds, moves, and changes.

Integration & Compatibility

The FHDEC2X2LYL is designed for use with Panduit FiberRunner 2x2 fiber routing systems in data centers and telecommunications central offices. It terminates open ends on hinged-lid channels and fittings in the 2x2 (2-inch by 2-inch / 50mm by 50mm) form factor. If you are running a different channel size in the same family, verify the matching end cap SKU — the press-fit geometry is size-specific. Competitor cross-reference: this cap is positioned against the FGS-HMEC-C from an alternate manufacturer, useful context if you are standardizing or replacing mixed-brand infrastructure.

What's in the Box

  • 1x Panduit FHDEC2X2LYL FiberRunner 2x2 End Cap (Yellow)

Frequently Asked Questions

Q: Does the FHDEC2X2LYL require a coupler or any hardware to install?

A: No. The FHDEC2X2LYL is a press-fit end cap — it mounts directly into the open end of the FiberRunner channel or fitting by hand. No coupler, no tools, and no additional hardware are required.

Q: What channel size does the FHDEC2X2LYL fit?

A: It is designed for the FiberRunner 2x2 system, covering 2-inch by 2-inch (50mm by 50mm) fiber routing channels and fittings. It is not interchangeable with other FiberRunner sizes.

Q: Is the FHDEC2X2LYL RoHS compliant?

A: Yes. The FHDEC2X2LYL meets RoHS requirements. It also carries UL listing for optical cable routing assemblies to the 2024A standard and conforms to Telcordia GR-63-CORE and NEBS Level 3 application tests.

Q: What is the carton quantity for the FHDEC2X2LYL?

A: The FHDEC2X2LYL is sold in a package quantity of 1, with a carton quantity of 5. Order multiples if you are terminating several channel runs in a single project.

Q: What environments is the FHDEC2X2LYL rated for?

A: It is specified for data centers and telecommunications central offices. Compliance with NEBS Level 3 (Telcordia GR-63-CORE) makes it suitable for carrier-grade and central office installations subject to seismic and environmental performance requirements.

Eden Phillips
Eden Phillips

The FHDEC2X2LYL is the kind of component that gets overlooked in a BOM until an inspection flags an open channel end or a cable pull damages an exposed fiber at a termination point. At 0.58 inches deep and a true press-fit design, this end cap installs in under five seconds per location — no tools, no coupler — which matters when you are closing out 40 or 50 channel ends on a dense overhead pathway in a live data center.

Technical Highlights:

  • NEBS Level 3 / GR-63-CORE: Satisfies the seismic and environmental performance tests required in carrier hotel and central office deployments — this is the compliance tier that gets scrutinized on telco buildouts, and the end cap doesn't break the assembly's listing.
  • UL-Listed to 2024A: The entire FiberRunner optical cable routing assembly, including this end cap, carries UL certification to the 2024A standard. That listing is what your AHJ will ask for at sign-off.
  • Polycarbonate/ABS Material: Not a commodity plastic — the blend handles localized heat from high-density rack environments without deforming, and the ABS component provides enough impact resistance for ladder-rack and overhead pathway installations where physical contact is routine.

Deployment Considerations:

  • The FHDEC2X2LYL is size-specific to the 2x2 (50mm × 50mm) FiberRunner channel. If your installation mixes channel sizes, order the matching end cap SKU for each size — the press-fit geometry will not transfer between sizes.
  • Package quantity is 1 unit; carton quantity is 5. For a full rack-row termination project, order in carton multiples to avoid shortages mid-installation — these are easy to undercount on the initial BOM.

This end cap belongs on every FiberRunner 2x2 channel termination in a data center or central office build — specifically where open channel ends are exposed to foot traffic, raised-floor plenum airflow, or physical cable management activity during ongoing adds and changes.

Specifications
Sub Brand: FiberRunner™
Application: Data centers et bureaux de télécommunication centraux
Color: Jaune
Material: Polycarbonate/ABS
Height In: 2.14
Height Mm: 54.4
Width In: 2.37
Width Mm: 60.2
Product Type: Embout
Carton Qty: 5
Package Qty: 1
Standards: Conforme RoHS, assemblages de guidage de câble optique certifiés UL jusqu'à 2024A, conformes aux épreuves d'application des normes Telcordia GR-63-CORE et Network Equipment Building Systems niveau 3
Upc: 61305676736
Cable Category: wire-routing-management-protection
Q&A
Reviews
Have Questions?

Panduit Fitting END CAP 2IN X 2IN 50MM X 50MM EA

$21.48
$13.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources