Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: QCPBCCB0001F030
Condition: New
Write a Review 35% OFF

Panduit CU QN TRUNKCAT6UTP Plenum Stdpkg 30FT PK1 - QCPBCCB0001F030

Panduit QCPBCCB0001F030 Cat6 UTP Plenum Copper Trunk Cable 30ftOverviewThe Panduit QCPBCCB0001F030 is a 30-foot Category 6 unshielded twisted pair (UT…

$1,290.66 $835.99 SAVE $455
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Panduit CU QN TRUNKCAT6UTP Plenum Stdpkg 30FT PK1 - QCPBCCB0001F030

$1,290.66
$835.99

Overview

SKU: QCPBCCB0001F030
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit QCPBCCB0001F030 Cat6 UTP Plenum Copper Trunk Cable 30ft

Overview

The Panduit QCPBCCB0001F030 is a 30-foot Category 6 unshielded twisted pair (UTP) plenum-rated copper trunk cable engineered for structured cabling deployments in data centers, telecommunications rooms, and enterprise backbone environments. If you are running horizontal or backbone copper runs through air-handling plenum spaces and need a pre-terminated, standards-compliant trunk assembly that installs clean and fast, this is the correct cable assembly to specify. At 250 MHz bandwidth and 1 Gbps data rate, it meets the full Cat6 channel performance envelope for 10/100/1000BASE-T applications across a 30-foot fixed-length run.

Panduit's structured cabling line is engineered to TIA-568-C.2 and ISO/IEC 11801 — the two standards most enterprise cabling specifications will actually call out in an RFP or scope of work.

Key Features

  • Category 6 Performance at 250 MHz: Cat6 certification at 250 MHz means this trunk handles 1 Gbps Ethernet with full headroom. You are not running at the edge of the spec — the 250 MHz bandwidth gives margin against NEXT and alien crosstalk in dense trunk environments typical of telecom rooms with multiple parallel runs.
  • 1 Gbps Data Rate: Supports 1000BASE-T across the 30-foot assembly length, which covers the overwhelming majority of IDF-to-patch-panel and TOR-to-patch-panel distances in standard rack-and-row data center deployments. If your runs need 10GBASE-T, this is a Cat6 (not Cat6A) assembly — see below for guidance.
  • UTP (Unshielded) Construction: No foil or braid shielding means simpler termination, no continuity-of-shield concerns at the connector, and lower overall installed weight in trunk bundles. UTP is the correct choice when your environment has well-managed EMI and you are not running next to high-voltage or motor-drive cabling.
  • Plenum (CMP) Rating: The CMP jacket rating satisfies NEC Article 800 for installation in air-handling plenum spaces without conduit. This is the correct jacket class for above-ceiling horizontal runs in commercial buildings where the ceiling cavity is used for HVAC return air — using a non-plenum cable in that space fails inspection and creates a smoke/fire code violation.
  • Pre-terminated Trunk Assembly, 30ft Fixed Length: Factory-terminated trunk assemblies eliminate field termination error, reduce installation labor, and provide consistent, tested performance. The 30-foot length fits standard two-post and four-post rack environments where patch panels are in adjacent or nearby racks within the same row.
  • TIA-568-C.2 and ISO/IEC 11801 Compliance: These are the governing standards for commercial building telecommunications cabling. TIA-568-C.2 is the US standard called out by most domestic enterprise cabling specs; ISO/IEC 11801 covers the international equivalent. Dual compliance means this assembly is specifiable on both domestic and global projects without substitution.
  • UL Listed: UL Listing is the independent verification that the cable construction meets the fire and safety requirements tested to UL 444 (communications cables). Most commercial AHJs require UL Listing on installed communications cable — this satisfies that requirement.

Integration and Compatibility

The QCPBCCB0001F030 is designed to integrate into Panduit's QuickNet structured cabling system, which uses pre-terminated trunk assemblies paired with QuickNet modules and patch panels. In a standard deployment, this trunk connects between a QuickNet patch panel at the main distribution area and a corresponding panel at the intermediate distribution frame. The Cat6 UTP interface is universally compatible with standard RJ-45 patch panels, switches, and structured cabling infrastructure from other manufacturers — you are not locked into a closed system.

For environments where you are deploying PoE network switches with 802.3af/at/bt requirements, Cat6 UTP at 250 MHz is fully compliant for 4-pair power delivery per TIA TSB-184-A. The UTP construction does introduce higher loop resistance than shielded alternatives, which is worth factoring if you are pushing PoE++ (802.3bt Type 4) at the far end of longer runs — but at 30 feet, this is not a limiting factor.

Pair this assembly with Cat6 copper patch cables at each end to complete the channel. The channel performance budget assumes the trunk plus two patch cords — verify the combined insertion loss of your specific patch cords does not exceed the TIA-568-C.2 channel insertion loss limit for Cat6 at 250 MHz.

See the structured cabling planning guide for trunk length selection, zone cabling layouts, and channel budget worksheets that apply directly to this type of deployment.

Frequently Asked Questions

Q: Is the QCPBCCB0001F030 suitable for installation in air-handling plenum ceiling spaces?

A: Yes. The QCPBCCB0001F030 carries a plenum (CMP) jacket rating, which satisfies NEC Article 800 requirements for installation in plenum air-handling spaces without conduit. This is the correct and required jacket rating for above-ceiling horizontal runs in commercial buildings where the ceiling cavity serves as HVAC return air.

Q: Does the QCPBCCB0001F030 support 10GBASE-T?

A: No. The QCPBCCB0001F030 is a Category 6 cable rated to 250 MHz and 1 Gbps. 10GBASE-T over copper requires Category 6A (500 MHz) to achieve reliable 10 Gbps performance at standard channel lengths. For 10GbE copper trunk applications, specify a Cat6A assembly instead.

Q: What standards does the QCPBCCB0001F030 comply with?

A: The QCPBCCB0001F030 is compliant with TIA-568-C.2 (US commercial building cabling standard), ISO/IEC 11801 (international equivalent), and is UL Listed. These three certifications cover domestic and international enterprise cabling specifications and satisfy most commercial AHJ inspection requirements.

Q: Is the QCPBCCB0001F030 compatible with non-Panduit patch panels and switches?

A: Yes. The RJ-45 Cat6 interface is a universal standard. This trunk assembly is compatible with any standards-compliant Cat6 patch panel, keystone module, or switch port from any manufacturer. Full channel performance per TIA-568-C.2 requires that all channel components (trunk, patch cords, connectors) individually meet Cat6 requirements.

Q: Can the QCPBCCB0001F030 be used for PoE applications?

A: Yes. Cat6 UTP at 250 MHz is compliant for 4-pair PoE delivery per TIA TSB-184-A, covering 802.3af, 802.3at, and 802.3bt applications. At a 30-foot run length, the UTP loop resistance is well within PoE channel limits for all standard power classes.

Q: What is the package quantity for the QCPBCCB0001F030?

A: The QCPBCCB0001F030 is sold as a standard package of 1 (PK1) — one 30-foot pre-terminated copper trunk cable assembly per unit.

Marty Allison
Marty Allison

The QCPBCCB0001F030 is a straightforward specification decision when you know what you are building: a 30-foot Cat6 UTP plenum trunk running at 250 MHz inside a commercial building's structured cabling backbone. Where I see this assembly earn its place is in IDF closets where the patch panel is one or two racks away from the switch — the pre-terminated factory construction eliminates the variability you get from field-terminated bulk cable, and the CMP jacket means you will not have a problem with the building inspector on plenum-space runs.

Technical Highlights:

  • 250 MHz Cat6 Bandwidth: The 250 MHz rating gives you genuine headroom on NEXT and return loss in dense trunk bundles — not just a nameplate claim. In a telecom room with 20+ parallel trunks, that margin matters for sustained link stability.
  • UTP Construction for Clean PoE Delivery: At 30 feet, UTP loop resistance is well within TIA TSB-184-A limits for 802.3bt Type 4 (90W PoE). You will not see thermal derating at this length even under full four-pair power load.
  • Dual Standards Compliance (TIA-568-C.2 / ISO/IEC 11801): Both standards on a single assembly means this SKU works on domestic projects and on international projects with the same spec sheet — no substitution request required when a project scope spans sites.

Deployment Considerations:

  • This is a fixed 30-foot assembly — measure your actual trunk run before ordering. Pre-terminated trunks cannot be extended in the field; over-ordering length creates cable management problems and adding slack loops to a Cat6 channel can marginally affect insertion loss at 250 MHz.
  • UTP has no shield continuity requirement, but that also means it provides no inherent EMI rejection. If this trunk runs parallel to 480V motor-drive cabling, variable frequency drives, or fluorescent ballasts for more than a few feet, consider a shielded (F/UTP or S/FTP) Cat6 variant instead — UTP in a high-EMI environment will show up as intermittent link errors that are difficult to root-cause after the fact.

This assembly is the right pick for a standard commercial IDF-to-patch-panel backbone run in a new-construction or retrofit office or campus building — particularly where the AHJ is strict on plenum jacket requirements and the project spec calls out TIA-568-C.2 by name.

Specifications
Cable Category: fiber_optic
Application: High-performance copper connectivity for data centers, telecommunications rooms, and enterprise networking environments.
Bandwidth: 250 MHz
Data Rate: 1 Gbps
Product Type: Copper Trunk Cable
Shielding: UTP (Unshielded)
Standards: TIA-568-C.2, ISO/IEC 11801, UL Listed
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources