Panduit
SKU: QCPBCCB0001F028
Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Panduit QCPBCCB0001F030 is a 30-foot Category 6 unshielded twisted pair (UTP) plenum-rated copper trunk cable engineered for structured cabling deployments in data centers, telecommunications rooms, and enterprise backbone environments. If you are running horizontal or backbone copper runs through air-handling plenum spaces and need a pre-terminated, standards-compliant trunk assembly that installs clean and fast, this is the correct cable assembly to specify. At 250 MHz bandwidth and 1 Gbps data rate, it meets the full Cat6 channel performance envelope for 10/100/1000BASE-T applications across a 30-foot fixed-length run.
Panduit's structured cabling line is engineered to TIA-568-C.2 and ISO/IEC 11801 — the two standards most enterprise cabling specifications will actually call out in an RFP or scope of work.
The QCPBCCB0001F030 is designed to integrate into Panduit's QuickNet structured cabling system, which uses pre-terminated trunk assemblies paired with QuickNet modules and patch panels. In a standard deployment, this trunk connects between a QuickNet patch panel at the main distribution area and a corresponding panel at the intermediate distribution frame. The Cat6 UTP interface is universally compatible with standard RJ-45 patch panels, switches, and structured cabling infrastructure from other manufacturers — you are not locked into a closed system.
For environments where you are deploying PoE network switches with 802.3af/at/bt requirements, Cat6 UTP at 250 MHz is fully compliant for 4-pair power delivery per TIA TSB-184-A. The UTP construction does introduce higher loop resistance than shielded alternatives, which is worth factoring if you are pushing PoE++ (802.3bt Type 4) at the far end of longer runs — but at 30 feet, this is not a limiting factor.
Pair this assembly with Cat6 copper patch cables at each end to complete the channel. The channel performance budget assumes the trunk plus two patch cords — verify the combined insertion loss of your specific patch cords does not exceed the TIA-568-C.2 channel insertion loss limit for Cat6 at 250 MHz.
See the structured cabling planning guide for trunk length selection, zone cabling layouts, and channel budget worksheets that apply directly to this type of deployment.
Q: Is the QCPBCCB0001F030 suitable for installation in air-handling plenum ceiling spaces?
A: Yes. The QCPBCCB0001F030 carries a plenum (CMP) jacket rating, which satisfies NEC Article 800 requirements for installation in plenum air-handling spaces without conduit. This is the correct and required jacket rating for above-ceiling horizontal runs in commercial buildings where the ceiling cavity serves as HVAC return air.
Q: Does the QCPBCCB0001F030 support 10GBASE-T?
A: No. The QCPBCCB0001F030 is a Category 6 cable rated to 250 MHz and 1 Gbps. 10GBASE-T over copper requires Category 6A (500 MHz) to achieve reliable 10 Gbps performance at standard channel lengths. For 10GbE copper trunk applications, specify a Cat6A assembly instead.
Q: What standards does the QCPBCCB0001F030 comply with?
A: The QCPBCCB0001F030 is compliant with TIA-568-C.2 (US commercial building cabling standard), ISO/IEC 11801 (international equivalent), and is UL Listed. These three certifications cover domestic and international enterprise cabling specifications and satisfy most commercial AHJ inspection requirements.
Q: Is the QCPBCCB0001F030 compatible with non-Panduit patch panels and switches?
A: Yes. The RJ-45 Cat6 interface is a universal standard. This trunk assembly is compatible with any standards-compliant Cat6 patch panel, keystone module, or switch port from any manufacturer. Full channel performance per TIA-568-C.2 requires that all channel components (trunk, patch cords, connectors) individually meet Cat6 requirements.
Q: Can the QCPBCCB0001F030 be used for PoE applications?
A: Yes. Cat6 UTP at 250 MHz is compliant for 4-pair PoE delivery per TIA TSB-184-A, covering 802.3af, 802.3at, and 802.3bt applications. At a 30-foot run length, the UTP loop resistance is well within PoE channel limits for all standard power classes.
Q: What is the package quantity for the QCPBCCB0001F030?
A: The QCPBCCB0001F030 is sold as a standard package of 1 (PK1) — one 30-foot pre-terminated copper trunk cable assembly per unit.

The QCPBCCB0001F030 is a straightforward specification decision when you know what you are building: a 30-foot Cat6 UTP plenum trunk running at 250 MHz inside a commercial building's structured cabling backbone. Where I see this assembly earn its place is in IDF closets where the patch panel is one or two racks away from the switch — the pre-terminated factory construction eliminates the variability you get from field-terminated bulk cable, and the CMP jacket means you will not have a problem with the building inspector on plenum-space runs.
Technical Highlights:
Deployment Considerations:
This assembly is the right pick for a standard commercial IDF-to-patch-panel backbone run in a new-construction or retrofit office or campus building — particularly where the AHJ is strict on plenum jacket requirements and the project spec calls out TIA-568-C.2 by name.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Panduit products? Shop the full Panduit catalog →
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price