Overview

SKU: QCPBCCB0001F022
Condition: New
Write a Review 41% OFF

Panduit CU QN TRUNKCAT6UTP Plenum Stdpkg 22FT PK1 - QCPBCCB0001F022

Panduit QCPBCCB0001F022 Cat6 UTP Plenum Copper Trunk Cable, 22 ftOverviewThe Panduit QCPBCCB0001F022 is a 22-foot Category 6 UTP plenum-rated copper t…

$1,223.78 $725.99 SAVE $498
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Panduit CU QN TRUNKCAT6UTP Plenum Stdpkg 22FT PK1 - QCPBCCB0001F022

$1,223.78
$725.99

Overview

SKU: QCPBCCB0001F022
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit QCPBCCB0001F022 Cat6 UTP Plenum Copper Trunk Cable, 22 ft

Overview

The Panduit QCPBCCB0001F022 is a 22-foot Category 6 UTP plenum-rated copper trunk cable engineered for pre-terminated horizontal distribution in data centers, telecommunications rooms, and enterprise network closets. Trunk cables like this one are the backbone of zone cabling architectures — you run one pre-terminated assembly from the main distribution area to a consolidation point or zone enclosure, then fan out to individual endpoints, eliminating field termination at every drop. The result is a cleaner install, faster commissioning, and a traceable, tested link every time. If you're building out a structured cabling plant and want to reduce on-site labor while maintaining compliance with current standards, a factory-terminated trunk assembly is the practical answer.

The QCPBCCB0001F022 ships as a single-pack (PK1) 22-foot assembly, sized for shorter runs between adjacent racks or from a telecom room to a nearby zone enclosure. At 22 feet, it fits comfortably within the same room or an adjacent aisle without excess slack management overhead.

Key Features

  • Category 6 Performance at 250 MHz: Cat6 spec at 250 MHz doubles the bandwidth headroom of Cat5e — meaningful when you're running Gigabit Ethernet today and don't want to recable when VoIP, PoE-powered devices, or higher-density switching demands increase. Every link in this trunk is tested to Cat6 insertion loss and NEXT parameters before it ships.
  • 1 Gbps Data Rate Support: Rated for 1 Gbps Ethernet (1000BASE-T) across the full 22-foot length. In a zone cabling layout feeding workstations, IP cameras, access control readers, or PoE switches, this trunk handles standard enterprise traffic loads without bottlenecking the channel.
  • UTP Construction — No Ground Required: Unshielded twisted pair means no bonding, no dedicated ground conductor, and no compatibility concerns with non-shielded patch panels or switch ports. In environments without significant EMI (most office and data center interiors), UTP simplifies installation and eliminates the grounding continuity issues that plague improperly installed STP plants.
  • Plenum (CMP) Rating — Required for Air-Handling Spaces: The plenum jacket rating (CMP) is not optional in ceiling plenums or raised-floor air-return spaces — local fire codes and NEC require it. This cable can be installed in air-handling spaces without conduit where a riser or general-purpose cable cannot. If your project spec calls for plenum spaces, this is the correct jacket type; using a cheaper riser-rated assembly in a plenum space is a code violation.
  • TIA-568-C.2 and ISO/IEC 11801 Compliance: Both the North American TIA standard and the international ISO/IEC 11801 standard are satisfied, so this cable supports documentation for projects requiring dual-standard certification — common in enterprise and government deployments where the structured cabling plant must be formally warranted.
  • UL Listed: UL listing means the cable has been independently tested and certified by Underwriters Laboratories. For commercial construction and government projects, UL listing is frequently a specification requirement, not just a nice-to-have, and it simplifies the AHJ approval process.
  • Factory-Terminated Trunk Assembly: Unlike bulk cable pulled and terminated on-site, this trunk is assembled and tested at the factory. That means each connector is seated, tested to Cat6 channel parameters, and shipped verified — no field termination errors, no re-punches, no post-installation link failures from a bad crimp or mis-wired pair. For high-density rollouts where a single bad termination can take hours to diagnose, factory-terminated assemblies are a risk reduction tool, not a luxury.

Integration & Compatibility

The QCPBCCB0001F022 is designed for integration into Panduit's QuickNet (QN) structured cabling system, which uses modular zone enclosures, patch panels, and consolidation points sized for the trunk connector format on this cable. It is compatible with Cat6 patch panels and modular jacks conforming to TIA-568-C.2, meaning it works within mixed-vendor infrastructure as long as the termination hardware meets the same standard. Pair this trunk with a PoE network switch and matching Cat6 patch cables to complete a compliant horizontal cabling channel. For guidance on planning structured cabling channel lengths and zone cabling topologies, consult a structured cabling planning guide. Browse the full Panduit connectivity catalog for compatible patch panels, zone enclosures, and cable management. For data center and telecom room builds, also consider cable management solutions to maintain bend radius and airflow alongside trunk runs.

Frequently Asked Questions

Q: What is the QCPBCCB0001F022 used for?

A: It is a 22-foot Cat6 UTP plenum copper trunk cable used in zone cabling architectures to connect distribution points to consolidation points or zone enclosures in data centers and enterprise telecom rooms. It ships factory-terminated and tested to TIA-568-C.2 and ISO/IEC 11801 standards.

Q: Can the QCPBCCB0001F022 be installed in a ceiling plenum without conduit?

A: Yes. The plenum (CMP) jacket rating allows installation in air-handling ceiling spaces and raised-floor plenums without conduit, in compliance with NEC requirements. Riser-rated or general-purpose cables cannot legally substitute in these spaces.

Q: Does this cable support Gigabit Ethernet?

A: Yes. The QCPBCCB0001F022 is rated for 1 Gbps data rates (1000BASE-T) at 250 MHz bandwidth — fully compliant with Cat6 performance specifications for standard enterprise Gigabit networking.

Q: Does UTP mean I need to worry about EMI interference?

A: UTP (unshielded twisted pair) is appropriate for most office and data center environments where EMI is not a significant factor. If your installation is near heavy electrical equipment, motors, or other strong EMI sources, a shielded (STP/FTP) cable may be a better fit. In standard commercial environments, UTP is the norm and simplifies installation by eliminating the need for grounding continuity.

Q: Is the QCPBCCB0001F022 compatible with non-Panduit patch panels?

A: The cable meets TIA-568-C.2 and ISO/IEC 11801, so it is compatible with any Cat6-compliant patch panel or modular jack that conforms to the same standards, regardless of manufacturer. For best performance and warranty coverage, Panduit recommends pairing with Panduit QuickNet system components.

Q: What does UL Listed mean for this cable?

A: UL Listed means the cable has been independently tested and certified by Underwriters Laboratories to meet applicable safety and performance standards. It is a common requirement in commercial construction specifications and simplifies approval by the Authority Having Jurisdiction (AHJ) on permitted projects.

James Everett
James Everett

The QCPBCCB0001F022 lands in a specific lane that buyers sometimes overlook when speccing trunk assemblies: the 22-foot length targets same-room or adjacent-aisle distribution runs where a longer trunk would create unmanageable slack and a shorter one wouldn't reach. The 250 MHz Cat6 spec gives you real headroom over Cat5e — not a paper spec bump, but a measurable difference in NEXT and return loss performance that matters when you're running Gigabit to PoE-powered endpoints like IP cameras or access control hardware hanging off the same channel.

Technical Highlights:

  • 250 MHz Cat6 Bandwidth: Twice the bandwidth headroom of Cat5e, tested to TIA-568-C.2 insertion loss and crosstalk parameters — each trunk verified at the factory, not field-tested after installation.
  • Plenum (CMP) Jacket: Mandatory for NEC-compliant installs in air-handling ceiling or raised-floor spaces. Using a riser cable here isn't a spec deviation — it's a code violation that will fail inspection.
  • UTP — No Grounding Infrastructure Required: In a standard data center or telecom room with reasonable EMI environment, unshielded construction keeps the install straightforward; no ground bonding, no continuity checks, no impedance mismatch from an incomplete shield.

Deployment Considerations:

  • At 22 feet, this trunk is sized for intra-room runs — main distribution frame to a nearby zone enclosure or adjacent rack. If your run exceeds the permanent link budget (typically 90 meters channel-total including patch cords), you need a different length, not a different category.
  • UTP construction is appropriate for most commercial interiors, but if this trunk runs parallel to 480V power conduit or through a mechanical room with VFDs, expect noise — switch to an STP variant for those specific paths rather than retrofitting shielding after the fact.

This trunk assembly is the right pick for structured cabling rollouts in enterprise data centers and telecom rooms where zone cabling architecture is being deployed, plenum compliance is required by spec, and the distribution distance falls in the 15–25 foot range between distribution and consolidation points.

Specifications
Cable Category: fiber_optic
Application: High-performance copper connectivity for data centers, telecommunications rooms, and enterprise networking environments.
Bandwidth: 250 MHz
Data Rate: 1 Gbps
Product Type: Copper Trunk Cable
Shielding: UTP (Unshielded)
Standards: TIA-568-C.2, ISO/IEC 11801, UL Listed
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources