Vertiv BRF060-1023 Basic Nonsurge 20A - 27853
Basic, nonsurge power distribution unit (PDU) designed for rack-mounted IT equipment
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv BRF100-1025 (part number 27928) is a no-frills, workhorse rackmount PDU built for IT environments that need reliable, code-compliant power distribution without the cost overhead of switched or metered units. Rated at 20A / 120V (1.9kW capacity), it delivers power to up to 10 NEMA 5-20R receptacles from a single 20A circuit — purpose-built for standard 5-20P branch circuits common in data centers, server rooms, and telecom closets. It ships from USA manufacturing, carries TAA and Buy American Act COTS compliance, and backs every unit with a 5-year limited warranty from Vertiv.
This unit fits the rackmount power distribution category squarely — a horizontal 1U form factor that occupies one rack space while keeping outlets accessible and organized. Every unit is 100% factory-tested before it ships, which matters when you're commissioning a rack remotely or on a tight schedule. Browse the full Vertiv power and infrastructure line for complementary PDU configurations and UPS options.
The Vertiv 27928 is a passive power distribution unit — no network interface, no management software, and no driver installation required. It integrates into any rack environment that provides a NEMA 5-20P outlet on a 20A branch circuit. Compatible with standard server racks and cabinets using EIA-310 19-inch rail spacing. The adjustable mounting brackets handle both shallow and deep four-post configurations. For deployments requiring per-outlet switching, current monitoring, or remote power cycling, evaluate the metered or switched tiers within the Vertiv PowerIT rPDU family — the BRF100-1025 deliberately omits those features to minimize cost and failure surface in non-managed environments.
If your rack includes a UPS, confirm the UPS output receptacle is NEMA 5-20R or that an appropriate adapter is in spec — the 5-20P plug will not seat in a standard 5-15R outlet without an adapter, and adapters introduce a code compliance question worth resolving before commissioning. See our UPS selection guide for compatible upstream power protection options.
Q: Is the Vertiv BRF100-1025 TAA compliant?
A: Yes. The BRF100-1025 is manufactured in the USA and carries both TAA compliance and Buy American Act COTS compliance, making it eligible for federal, state, and municipal procurement programs with domestic sourcing requirements.
Q: What plug type does the 27928 use, and will it fit a standard 20A wall outlet?
A: The unit ships with a NEMA 5-20P plug, which fits NEMA 5-20R receptacles — the standard 20A, 120V outlet found on dedicated 20A branch circuits. It will not plug directly into a standard 15A (NEMA 5-15R) outlet without an adapter; a dedicated 20A circuit is required.
Q: What is the warranty on the BRF100-1025?
A: Vertiv covers the BRF100-1025 with a 5-year limited warranty, which is the standard coverage for their PowerIT rPDU Basic line.
Q: Can I mount the 27928 in a two-post relay rack?
A: The unit is designed for 19-inch EIA-310 four-post racks and cabinets with adjustable mounting brackets. Two-post relay rack compatibility depends on whether the rack provides standard 19-inch mounting holes at the correct spacing — the brackets are adjustable, but a two-post open-frame rack may require a rack shelf or additional mounting hardware depending on rail configuration.
Q: How many outlets does the BRF100-1025 provide, and what is the receptacle type?
A: Ten NEMA 5-20R duplex receptacles, all rated at 20A / 120V. All 10 outlets share a single 20A thermal breaker.
Q: Does the BRF100-1025 have surge protection?
A: No. The BRF100-1025 is a basic (non-surge) PDU — it provides over-current protection via a 20A thermal breaker only. It does not include surge suppression or line conditioning. If surge protection is required, select a unit from the Vertiv surge-protected PDU tier.

The Vertiv 27928 is the PDU I spec when the rack environment has a dedicated 20A / 120V branch circuit and zero budget for features that won't get used — no SNMP, no current monitoring, no switched outlets. The 1.9kW continuous load ceiling at 120V is the honest constraint to plan around: at the NEC 80% derate, you're working with 1.52kW of usable capacity, which covers most 1U or 2U server-plus-switch combinations but can get tight on a fully loaded 2U compute node with a GPU or a high-density PoE switch.
Technical Highlights:
Deployment Considerations:
The BRF100-1025 is the right call for a federal or municipal project rack where TAA compliance is a hard requirement, the circuit is a dedicated 20A drop, and management overhead on the PDU itself adds no value — telecom closets, edge compute nodes, and government-spec server rooms are the home environment for this unit.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Vertiv products? Shop the full Vertiv catalog →
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price