Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: SUA750IX38
Condition: New
Write a Review 33% OFF

APC Smart UPS 750VA 230V USB with UL Approval - SUA750IX38

APC by Schneider Electric SUA750IX38 Smart UPS 750VA Line-Interactive Uninterruptible Power SupplyOverviewThe APC by Schneider Electric SUA750IX38 is …

$767.00 $514.99 SAVE $252
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

APC Smart UPS 750VA 230V USB with UL Approval - SUA750IX38

$767.00
$514.99

Overview

SKU: SUA750IX38
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric SUA750IX38 Smart UPS 750VA Line-Interactive Uninterruptible Power Supply

Overview

The APC by Schneider Electric SUA750IX38 is a 750VA / 500W line-interactive UPS designed for small servers, network closets, and critical edge devices in commercial environments running 230V infrastructure. It delivers regulated output via IEC 60320 outlets, communicates over USB for graceful shutdown integration, and ships with hot-swappable batteries — so you can swap cells during a maintenance window without powering down connected equipment. If you're protecting a small NVR stack, a PoE switch feeding IP cameras, or a telecom shelf in a wiring closet, the SUA750IX38 sits at the right capacity and form factor for the job.

Key Features

  • 500W / 750VA Output Capacity: Sized for a single 1U server, a mid-range PoE switch, or a compact NVR with attached drives. At 500W true power delivery, you won't run into derating surprises when attaching real loads — 750VA with a 0.67 power factor is clearly stated, so plan your connected load accordingly.
  • 4.8 Minutes Full Load / 16.4 Minutes Half Load Runtime: Enough headroom at half load to ride through most utility brownouts and give a managed switch time to signal downstream devices before graceful shutdown. Full-load runtime is short — size connected loads at 50% or less of capacity if you need meaningful runtime for PoE network switches or recorders.
  • Hot-Swap Battery: Replace the internal battery without shutting down protected equipment. In a 24/7 surveillance or access control environment, this matters — battery life is typically 3–5 years, and a swap window that doesn't require a maintenance outage is a real operational advantage.
  • 3-Hour Battery Recharge Time: After a discharge event, the SUA750IX38 returns to full charge in 3 hours. For sites with frequent short outages, this keeps the battery topped up between events rather than leaving you vulnerable through a long recovery cycle.
  • 340J Surge Energy Rating: Provides meaningful suppression for voltage spikes on 230V circuits. Not a substitute for a proper surge protection device on the incoming feed, but adequate for protecting sensitive electronics downstream from the UPS output.
  • USB Communication Port: Connects directly to a host server or NVR for graceful shutdown scripting. Most major network video recorders and server OS platforms support APC's PowerChute or standard USB HID UPS protocol — no proprietary card required at this tier.
  • IEC 60320 AC Outlets: Standard IEC C13/C14 outlet format used universally on 1U servers, patch panels, and rack-mount equipment. No adapters needed for typical rack deployments in 230V regions.
  • LED Status Indicators with Audible Alarm: Visual and audible feedback on battery, overload, and fault conditions means you don't need a dedicated monitoring station to catch a problem — the unit announces issues locally. Useful in wiring closets where someone walks by regularly.
  • 0–40°C Operating Range: Covers standard indoor wiring closet and server room environments. Not rated for outdoor or unconditioned space — if ambient temperatures exceed 40°C (common in unventilated telecom enclosures in summer), derate runtime expectations or add ventilation.
  • Multi-Certification: CE, VDE, GOST, C-tick, IEC 60950, EN 50091: Covers European, Australian, and Russian market compliance. Relevant if you're deploying in multi-region projects or need documentation for a facilities compliance package.

Integration and Compatibility

The USB interface on the SUA750IX38 is compatible with standard USB HID UPS device class drivers, meaning Windows Server, Linux, and most NVR appliance operating systems will recognize it without additional software. For automated graceful shutdown, APC's PowerChute software adds scheduling and event logging. The IEC 60320 outlet format is native to rack-mount equipment — no pigtail adapters or plug converters needed in 230V deployments. For integrators building out UPS power protection racks alongside IP security systems, this unit pairs cleanly with compact PoE switches and single-recorder configurations. Review APC's full APC by Schneider Electric lineup if your load requirements exceed 500W or if you need extended runtime via external battery packs.

Frequently Asked Questions

Q: What is the runtime of the SUA750IX38 at full load versus half load?

A: At full load (500W), the SUA750IX38 provides approximately 4.8 minutes of runtime. At half load (250W), runtime extends to approximately 16.4 minutes. For meaningful ride-through time, keep connected loads at or below 50% of rated capacity.

Q: Does the SUA750IX38 support hot-swap battery replacement?

A: Yes. The SUA750IX38 supports hot-swap battery replacement, allowing the internal battery to be replaced without powering down connected equipment — an important feature for 24/7 installations.

Q: What output voltage and outlet type does the SUA750IX38 use?

A: The SUA750IX38 outputs 230V AC via IEC 60320 standard outlets (C13 format), compatible with standard rack-mount servers, switches, and NVR equipment.

Q: How long does the SUA750IX38 battery take to recharge after a discharge?

A: The battery recharges to full capacity in approximately 3 hours after a discharge event.

Q: What certifications does the SUA750IX38 carry?

A: The SUA750IX38 carries CE, VDE, C-tick, GOST, IEC 60950, EN 50091-1, EN 50091-2, and EN 55022 Class A certifications, covering European, Australian, and Russian market requirements.

Q: What is the operating temperature range for the SUA750IX38?

A: The SUA750IX38 is rated for operation between 0°C and 40°C (32°F to 104°F). It should not be installed in unconditioned or high-ambient spaces where temperatures exceed 40°C.

Eden Phillips
Eden Phillips

The SUA750IX38 is a unit I'd reach for specifically when the load is well-defined and modest — a single compact NVR, one managed PoE switch, or a critical access control panel in a wiring closet. The 500W true power capacity is honest and leaves no room for surprises, which is exactly what you want when you're sizing protection for equipment that can't afford an unplanned restart.

Technical Highlights:

  • Hot-Swap Battery: The ability to swap the internal battery while the SUA750IX38 remains online is the spec that matters most for 24/7 security infrastructure — no maintenance window required when cells hit end of life at the 3–5 year mark.
  • 16.4-Minute Half-Load Runtime: Running connected loads at 50% or less of the 500W capacity (250W) gives you over 16 minutes of ride-through — enough time to execute a graceful shutdown sequence over USB or wait out a typical utility event without data loss on a recording system.
  • Multi-Market Certifications (CE, VDE, GOST, C-tick, IEC 60950): For integrators deploying in European, Australian, or Russian projects, the certification stack on this unit means you can drop it into a compliance package without chasing additional approvals.

Deployment Considerations:

  • The USB connection enables graceful shutdown via standard HID UPS drivers — verify your NVR or server OS supports this before assuming PowerChute software is required. Most modern platforms handle it natively, which simplifies the installation.
  • The 4.8-minute full-load runtime is a hard constraint. If you're connecting a full 500W load and expecting meaningful outage coverage, you will be disappointed. Size your connected load at 40–50% of capacity if runtime is a priority — this unit is not suited for extended outage protection at full draw.

The SUA750IX38 is the right call for a compact 230V wiring closet protecting a single NVR or PoE switch stack where runtime of 15+ minutes at half load is acceptable and a hot-swap battery matters more than extended full-load coverage.

Specifications
Output power capacity: 0.75 kVA
Output power: 500 W
Input frequency: 50/60 Hz
Surge energy rating: 340 J
Audible alarm(s: Yes
AC outlet types: IEC 60320
Typical backup time at full load: 4.8 min
Typical backup time at half load: 16.4 min
Battery recharge time: 3 h
Hot-swap battery: Yes
Product colour: Black
LED indicators: Yes
Operating temperature (T-T: 0 - 40 °C
Storage temperature (T-T: -15 - 45 °C
Operating altitude: 0 - 3000 m
Non-operating altitude: 0 - 15000 m
Certification: C-tick,CE,EN 50091-1,EN 50091-2,EN 55022 Class A,GOST,IEC 60950,VDE
Weight: 13.2 kg
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources