Door Hardware & I/O
Sub categories
Showing Results for Door Hardware & I/O
-
HES
SKU: HEB-3BK-MM15
HES HEB-3BK-MM15 Header Extension Bracket
3-inch header extension bracket for HES MM15 electromagnetic locks
- 3-inch extension length adjusts mounting distance for varied frame configs
- Metal construction mounts to header/frame for secure lock positioning
- Designed specifically for HES MM15 series electromagnetic lock systems
$74.00 $73.99 Save $0.01 -
HES
SKU: HEB-3CL-12
HES HEB-3CL-12 Header Extension Bracket 12 Inch
12-inch header extension bracket for HES electromagnetic locks
- Clear anodized aluminum construction resists corrosion in commercial installations
- 12-inch length allows proper clearance and alignment on door headers
- Compatible with HES electromechanical locking devices for access control systems
$106.00 $105.99 Save $0.01 -
HES
SKU: HEB-3CL-8
HES HEB-3CL-8 Header Extension Bracket 8 inch
8-inch header extension bracket in clear anodized aluminum
- 8-inch length extends reach for retrofit and custom mounting layouts
- Clear anodized aluminum resists corrosion in commercial environments
- Compatible with HES mounting systems for access control hardware
$100.00 $99.99 Save $0.01 -
HES
SKU: HEB-3CL-MM15
HES HEB-3CL-MM15 Header Extension Bracket 3in
3-inch header extension bracket for HES MM15 magnetic locks
- Extends header mounting reach 3 inches to fit non-standard door frame configurations.
- Designed specifically for HES MM15 series magnetic locks, ensuring direct compatibility.
- US-manufactured plate-mount bracket supports 24VDC lock systems in retrofit installs.
$57.00 $56.99 Save $0.01 -
HES
SKU: HEB-3G
HES HEB-3G Header Extension Bracket 3x3x8 Glass
Glass door header bracket, 3x3x8 aluminum for access control hardware
- Clear anodized aluminum resists corrosion in commercial environments
- 8" vertical extension reaches above standard door frame mounting points
- Precision mounting surface for electromagnetic locks and overhead hardware
$120.00 $119.99 Save $0.01 -
HES
SKU: HESCUT-MTK
HES HESCUT-MTK Metal Template Installation Kit
Metal template kit cuts electric strike installation time by 30–50 minutes
- Precision machined guides eliminate manual measurement and layout errors
- Works with all HES electric strike lines on wood, aluminum, and hollow metal frames
- Speeds both new construction and retrofit deployments across multiple doors
$113.00 $112.99 Save $0.01 -
HES
SKU: HM-630
HES HM-630 1006 Series Satin Stainless Steel Faceplate
Satin stainless steel faceplate for HES 1006 Series electric strikes
- Corrosion-resistant satin finish for commercial and institutional access control
- Purpose-built compatibility with HES 1006 Series electromechanical hardware
- Durable stainless steel construction handles varied indoor and moderate outdoor use
$83.00 $82.99 Save $0.01 -
HES
SKU: HTD-605
HES HTD-605 1006 Series Bright Brass Faceplate
Bright brass faceplate for HES 1006 Series electric strike
- Direct-fit replacement for HES 1006 Series strike hardware
- Brass construction with bright finish resists corrosion indoors
- Standard door frame mounting for commercial access control
$195.00 $194.99 Save $0.01 -
HES
SKU: HTD-630
HES HTD-630 Access Control Hardware
24VDC multi-door access controller for commercial facilities
- Coordinates credential verification across multiple entry points
- 24VDC input voltage supports standard access control architecture
- Professional-grade construction rated for high-traffic environments
$83.00 $41.99 Save $41.01 -
HES
SKU: J-2-630
HES J-2-630 1006 Series Faceplate Satin Stainless Steel
Satin stainless steel faceplate for HES 1006 Series electric strikes
- Satin stainless steel construction resists corrosion indoors and outdoors
- Direct compatibility with HES 1006 Series electric strike hardware
- Professional finish suitable for visible commercial access control areas
$107.00 $106.99 Save $0.01 -
HES
SKU: J-630
HES J-630 1006 Series Satin Stainless Steel Faceplate
Satin stainless steel 1006 Series faceplate for HES electrified locks
- Satin stainless steel resists corrosion and oxidation in high-traffic deployments.
- 1006 Series form factor mounts directly to standard electrical boxes, simplifying installs.
- Compatible with HES electrified locking hardware and standard access control trim kits.
$53.00 $52.99 Save $0.01 -
HES
SKU: JN-1
HES JN-1 Jack Nut Installation Tool Kit
Specialized jack nut installation toolkit for HES security hardware
- Complete tool set for jack nut installation and maintenance in access control systems
- Purpose-built for field technicians deploying HES electronic security infrastructure
- Supports proper electrical connections across commercial and industrial security deployments
$280.00 $279.99 Save $0.01 -
HES
SKU: KA-105A
HES KA-105A On/Off Key Switch with Key Remove
Panel-mount key switch with key-remove lock in ON position only
- Manual key-operated ON/OFF control with mechanical design for access systems
- Key remove function active only in ON position prevents unauthorized key removal
- Industrial-grade construction rated for repeated use in security enclosures
$101.00 $55.99 Save $45.01 -
HES
SKU: KA-106A
HES KA-106A Key Switch Round On/Off Keyed
Key-operated round switch with key-remove-off lockout for secure manual control
- Two-position on/off mechanical switching with 28VDC rated operation
- Key-remove-off design automatically returns to off when key is extracted
- Round panel-mount form factor fits standard control enclosures and security panels
$101.00 $55.99 Save $45.01 -
HES
SKU: KA-107A
HES KA-107A Momentary Key Switch 2-Key Keyed Alike
Momentary key switch for access control with 2 keyed-alike keys
- Momentary action activates only during key engagement, returns to neutral
- 2 keyed-alike keys simplify access management across multiple locations
- Mechanical design integrates with HES and third-party control systems
$78.00 $43.99 Save $34.01 -
HES
SKU: KA-109
HES KA-109 ON-OFF Key Switch
Keyed ON-OFF switch for access control and security systems
- Key-operated mechanism prevents unauthorized activation in control panels
- Compact, field-installable design fits standard access control architectures
- Durable professional-grade housing rated for commercial facility deployment
$68.00 $37.99 Save $30.01
Door Hardware & I/O
Door hardware and I/O components connect physical doors to your access control system. From electric strikes and magnetic locks to exit devices and relay modules, proper hardware selection ensures safe, compliant, and reliable operation.
Plan Your Deployment
- Fail-safe vs fail-secure lock configuration
- Door type (wood, metal, glass, storefront)
- Request-to-exit (REX) device requirements
- Power supply and voltage compatibility
- Local life-safety and fire code compliance
Door Hardware & I/O — Engineering-Grade Door Hardware for Commercial Deployments
This category covers 532 working models of door hardware & i/o sourced manufacturer-direct or through channel-direct US distribution. Build the rest of your system around the architectural choices below — compatibility, environmental rating, and lifecycle decisions made here propagate through every downstream component you specify.
What to Look For
Fail-safe versus fail-secure determines what happens during power loss. Fail-safe locks unlock on power loss (used on egress doors where life safety dominates); fail-secure locks remain locked (used on storage, server rooms, and exterior doors where security dominates). Code typically mandates fail-safe on stairwell and egress doors. Confirm with the AHJ before specifying — misapplied lock mode is a common code violation.
Strike, mortise, magnetic lock, and electrified panic hardware each have distinct installation, current draw, and code implications. Electric strikes work with most mechanical locksets and are easiest to retrofit. Magnetic locks (maglocks) provide high holding force on glass and wood doors but require dedicated REX and panic-bar interfaces for egress compliance. Verify the door's existing prep before choosing.
Power draw and inrush current dictate power supply sizing. A 5-door system with 1A peak per lock can exceed an undersized 12VDC supply at simultaneous lock-down events. Account for accessories — REX motion sensors, door-position switches, electrified levers — when sizing the supply and the battery backup required for code compliance.
Tamper switches, door-position monitoring, and request-to-exit sensors generate the audit trail your security team needs. Mechanical contact switches are cheaper; magnetic reed switches resist tampering better. Pair each door with a position switch and a REX sensor at minimum — without door-position monitoring, you can't distinguish 'authorized entry' from 'door held open after authorized entry,' which is a common compliance gap.
Key Specs in This Category
| Spec | Available Options |
|---|---|
| Resolution | 8MP, 2MP |
| IP Rating | IP66, IP67 |
| Connectivity | Wired |
| Power | AC/DC, Battery |
| Type | Accessory, Controller, Cable, Switch, Power Supply, Access Card, Contact, Lock/Strike |
| Night Vision | Yes |
Top Brands in This Category
Frequently Asked Questions
Fail-safe or fail-secure for stairwell doors?
Fail-safe is mandatory on most stairwell doors and other code-designated egress paths — the lock must release on fire alarm or power loss to allow evacuation. Fail-secure on those doors is a code violation. Confirm the local fire code and AHJ requirements; commercial buildings in the U.S. follow NFPA 101 and the International Building Code, both of which detail egress lock behavior in detail.
What current draw should I plan for electrified locks?
Typical 12VDC electric strikes draw 200-500 mA continuous, with inrush spikes of 1-2A at engagement. Magnetic locks rated for 1,200 lbs holding force draw around 500 mA continuous at 24VDC. Power supplies need to handle simultaneous lock-down current — emergency lockdown events activate all locks at once. Size the supply with at least 25% headroom and confirm battery backup runtime requirements.
Do I need a request-to-exit (REX) sensor?
Most code-compliant electrified door installations require a REX sensor to shunt the alarm during authorized egress. Without REX, every egress event registers as a forced-door alarm. PIR motion sensors are the common choice and integrate with the door controller's REX input. Mechanical push-bar REX is also acceptable for hardware that includes that switch natively.
Can I use one lock for both card and mechanical key entry?
Yes — most electrified strikes and locks allow mechanical key override on the same door. Maintaining a master key for emergency mechanical access is required by code in many jurisdictions and recommended in all. Document the master key holders carefully; an uncontrolled master key program undermines the electronic audit trail.
What's the lifespan of a magnetic lock?
Quality maglocks (Securitron M62, HES, von Duprin) typically last 15-20 years with no mechanical wear. Failure points are the connector, the armature plate-to-lock alignment, and contamination of the magnetic face. Plan for armature replacement at year 10 as a hedge against alignment drift. Strike-type locks with mechanical parts last 5-10 years before strike-plate wear becomes a reliability issue.
Need help choosing? Talk to a Senior Specialist — direct line 877-277-7147 or request a quote.