Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit FSCR606Y 6-Fiber OM1 Riser-Rated Indoor/Outdoor Cable

The Panduit FSCR606Y Opti-Core™ 6-fiber cable delivers a compact, dual-rated infrastructure backbone for commercial security and access-control installations that span indoor riser shafts and outdoor building-to-building pathways. This OM1 multimode cable pairs 62.5/125µm fiber with 250µm tight buffering and an OFNR (riser) flame rating, allowing vertical runs between floors and short outdoor exposures without conduit transitions or splice points. Security integrators deploying legacy OM1 camera systems, fiber intercom backbones, or access panels across parking structures gain a single-SKU solution that meets NEC Article 770 riser requirements indoors and withstands moisture ingress outdoors, eliminating the cost and labor of dual-cable designs.

Key Features

  • 6-Fiber OM1 Multimode (62.5/125µm) — supports up to 275m at 1Gb/s or 33m at 10Gb/s; backward-compatible with legacy OM1 infrastructure in corporate campuses, hospitals, and government facilities
  • OFNR Riser Flame Rating — UL 1666 certified for vertical cable trays, risers, and shafts without plenum air-handling restrictions; meets NEC 770.154(A) for general-purpose building backbone
  • Indoor/Outdoor Dual Rating — polyethylene jacket resists UV, moisture, and temperature cycling (-40°C to +70°C); eliminates splices at building-penetration points in campus deployments
  • 250µm Tight Buffer Construction — individual fibers buffered to 250µm (not 900µm distribution cable); optimized for direct connectorization with field-installable LC/SC connectors, reducing patch-panel bulk in telecom rooms
  • Opti-Core™ Sub-Brand — Panduit's standards-driven fiber portfolio with lot-tested insertion loss, guaranteed geometry, and cross-brand interoperability
  • Black Jacket — low-visibility aesthetic for exposed outdoor runs and mechanical-room installations; resists staining in dusty or industrial environments

The FSCR606Y employs a loose-tube central-member design with six OM1 (62.5/125µm) multimode fibers, each coated with a 250µm tight buffer layer. OM1 fiber, standardized under ISO/IEC 11801 and TIA-568, provides 200 MHz·km modal bandwidth at 850nm—sufficient for 1000BASE-SX Gigabit Ethernet links up to 275 meters or 10GBASE-SR 10-Gigabit links up to 33 meters. While newer OM3/OM4 fibers extend 10GbE reach, OM1 remains the dominant installed base in corporate and institutional networks built before 2010, making this cable essential for retrofit expansions, intercom trunk extensions, and access-control panel uplinks that must splice into existing OM1 backbones without mode-mismatch loss. The 250µm buffer strikes a middle ground between fragile 125µm bare fiber and bulky 900µm distribution cable: tight enough for direct field termination with Panduit's OptiCam or Corning UniCam connectors, yet robust enough to survive installation pulls through conduit without breakage. The loose-tube architecture isolates fibers from jacket stress during temperature swings, a critical feature for outdoor spans where a 50°C delta between summer and winter can induce microbendin loss in tight-buffered designs. The OFNR riser rating certifies flame propagation below UL 1666 thresholds, permitting vertical installation in cable trays and risers that penetrate floor assemblies—but not in return-air plenums, where OFNP plenum cable is required. For security integrators, this translates to legal compliance in the 80% of vertical pathways that do not involve HVAC air handling, at a lower cost than plenum-rated equivalents.

Deploy the FSCR606Y in multi-building campuses where a single fiber run must traverse both indoor riser shafts and outdoor aerial/underground segments. A典型 use case: a hospital security operations center on the third floor extending camera feeds to a remote parking structure 150 meters away. The cable exits the SOC through a riser shaft (OFNR-compliant), penetrates the exterior wall via a weatherhead, spans the parking lot on messenger wire or in direct-burial conduit (outdoor-rated jacket), and re-enters the parking structure's equipment closet—all without a splice or transition enclosure. The six-fiber count supports three duplex LC links: one active camera trunk (1000BASE-SX), one for future IP intercom or access panels, and one dark spare for fault tolerance or bandwidth upgrades. Because OM1's 275m Gigabit reach exceeds most intra-campus distances, integrators avoid the cost premium of OM3/OM4 fiber while maintaining standards-compliant headroom. The black jacket blends into conduit and plenum spaces, reducing visual clutter in exposed installations like parking garages or loading docks. For integrators retrofitting 1990s-era OM1 networks, the FSCR606Y's 62.5µm core diameter ensures native compatibility with legacy ST and SC connectors, avoiding the fusion-splice labor required when mixing OM1 and OM3 fibers. Installation follows standard fiber-handling protocol: maximum pull tension of 300 lbf (1,335 N) during installation, 100 lbf (445 N) long-term; minimum bend radius of 10× cable diameter under load, 5× at rest. Panduit specifies a 0.36 dB/km maximum attenuation at 850nm and 1.0 dB/km at 1300nm, with insertion loss guaranteed below 0.3 dB per mated connector pair when terminated with Panduit's factory or field connectors.

The FSCR606Y ships as a continuous-length cable (purchase by the foot or in bulk reels) and meets TIA-568-C.3 multimode fiber standards, UL 1666 riser flame test, and RoHS material restrictions. Panduit backs the Opti-Core line with a 25-year system warranty when installed per published guidelines and paired with Panduit connectivity. For integrators managing fiber across mixed indoor/outdoor environments—data centers extending to generator yards, corporate lobbies linking to parking-lot help points, or hospital nurse-call systems bridging between wings—the FSCR606Y eliminates the dual-specification complexity and splice-enclosure cost of separate indoor and outdoor cables, delivering a single tested assembly that meets both NEC riser code and environmental exposure requirements in one six-fiber package.

Specifications
Product Type: Loose Tube Fiber Optic Cable
Brand: Panduit
Sub-Brand: Opti-Core™
MPN: FSCR606Y
Fiber Type: OM1 Multimode
Fiber Core/Cladding: 62.5/125 µm
Number of Fibers: 6
Buffer Type: 250 µm Tight Buffer
Cable Construction: Loose Tube, Central Member
Jacket Material: Polyethylene (PE)
Jacket Color: Black
Flammability Rating: OFNR (Riser)
Indoor/Outdoor Rating: Indoor/Outdoor
Temperature Range: -40°C to +70°C
Maximum Attenuation (850nm: 0.36 dB/km
Maximum Attenuation (1300nm: 1.0 dB/km
Bandwidth (850nm: 200 MHz·km
Standards Compliance: TIA-568-C.3, UL 1666, NEC Article 770
Package Quantity: 1
UPC: 074983049190
Type: Fiber Optic Cable
Connectivity: Multimode Fiber
Durability: Indoor/Outdoor Rated
Sub Brand: Opti-Core™
Color: Noir
Fiber Count: 6
Carton Qty: 0
Package Qty: 1
Upc: 07498304919
Cable Category: fiber-optic-systems
Q&A
Reviews
Have Questions?

Panduit FSCR606Y 6-Fiber OM1 Riser Indoor/Outdoor Cable

$2.56
$1.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources