CyberPower CP2000PFCRM2U 2000VA Rackmount UPS

CyberPower CP2000PFCRM2U 2000VA Rackmount UPS The CyberPower CP2000PFCRM2U is a 2U rackmount UPS engineered for security NVRs, networked AV systems, a…

$499.95 $443.99 SAVE $56
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

CyberPower CP2000PFCRM2U 2000VA Rackmount UPS

$499.95
$443.99

Overview

SKU: CP2000PFCRM2U
UPC: 649532938056
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

CyberPower CP2000PFCRM2U 2000VA Rackmount UPS

The CyberPower CP2000PFCRM2U is a 2U rackmount UPS engineered for security NVRs, networked AV systems, and critical access control panels that require clean sine wave power and active PFC compatibility. Delivering 2000VA/1200W with true sine wave output, this line-interactive UPS protects eight NEMA 5-20R outlets through integrated surge suppression (1500J), EMI/RFI filtration, and Automatic Voltage Regulation. The compact 10.8-inch chassis depth fits shallow-rack environments common in telecom closets and wall-mount equipment cabinets where traditional deep UPS units won't fit.

Key Features

  • 2000VA/1200W Capacity — supports enterprise NVRs with 8+ drive bays, PoE switches powering 16-24 cameras, or multi-display video walls requiring sustained clean power during grid fluctuations
  • True Sine Wave Output — delivers utility-grade AC waveform required by active PFC power supplies found in modern servers, IP camera PoE injectors, and professional AV equipment; prevents compatibility issues and equipment damage common with simulated sine wave UPS units
  • Automatic Voltage Regulation (AVR) — corrects voltage sags and surges (82-144VAC input range) without switching to battery, extending battery lifespan and reducing nuisance alarms in facilities with marginal utility power quality
  • 8 NEMA 5-20R Outlets — all outlets provide both surge protection and battery backup; 20A receptacles accommodate high-current devices while accepting standard 15A plugs for mixed-load installations
  • Shallow 10.8" Depth — 2U rackmount form factor optimized for telecommunications racks, network cabinets, and AV equipment racks where rear clearance is limited; includes rack-mount hardware and supports both 2-post and 4-post rack configurations
  • Multifunction Color LCD — real-time display shows input/output voltage, load percentage, battery capacity, estimated runtime, and fault conditions; eliminates guesswork during commissioning and troubleshooting
  • Hot-Swappable Battery — front-access battery compartment allows replacement without powering down connected equipment or removing the UPS from the rack; user-replaceable design reduces service costs and downtime
  • Expandable Management — USB port for local monitoring via PowerPanel software; DB9 serial port with dry contact relay for integration with building automation systems; optional SNMP card slot enables remote SNMP traps, email alerts, and safe shutdown scripts for unattended installations
  • Network Line Protection — RJ45 surge protection supports 10/100/1000 Ethernet; protects management interfaces on NVRs, managed switches, and IP-connected access controllers from lightning-induced surges on data lines
  • GreenPower UPS Bypass — reduces energy consumption by bypassing the UPS circuitry when batteries are fully charged and utility power is stable; lowers operating temperature and extends component lifespan in 24/7 installations

Power Topology and Runtime: Line-interactive topology with AVR provides the optimal balance between double-conversion online UPS protection and the efficiency/heat profile suitable for rack-mount applications. The CP2000PFCRM2U continuously monitors utility voltage and automatically engages AVR buck/boost transformers when input voltage drifts outside the 108-132VAC ideal window, correcting voltage without battery discharge. This extends the two internal 12V/9Ah sealed lead-acid batteries' service life and reduces the frequency of battery replacement cycles. At half load (600W)—typical for an 8-camera PoE switch plus small 4-drive NVR—expect 9 minutes of runtime, sufficient for brief utility interruptions or orderly system shutdown during extended outages. At full 1200W load, runtime drops to 2.2 minutes, adequate for ride-through during transfer switch cutover or generator startup in facilities with backup power infrastructure. Battery recharge time is approximately 8 hours to 90% capacity. The user-replaceable battery design (accessible from the front panel without removing the unit from the rack) allows integrators to stock spare battery cartridges for rapid field service without scheduling manufacturer RMA returns.

Rack Integration and Load Management: The 2U 17-inch wide chassis installs in standard 19-inch EIA racks using the included mounting brackets; shallow 10.8-inch depth positions the unit forward in the rack, leaving rear clearance for patch panels and cable management. The NEMA 5-20P input plug terminates a 6-foot power cord, allowing flexible connection to facility circuits or rack-mount PDUs. All eight outlets are NEMA 5-20R (horizontal blade configuration), accepting both 15A and 20A plugs; there is no outlet segregation—all outlets share the same battery-backed surge-protected circuit. For installations requiring sequenced power-on (such as staggered NVR and switch boot to prevent inrush current trips), connect devices through a managed PDU downstream of the UPS, or use the optional SNMP/network card to script startup delays via the UPS management interface. The front-panel color LCD provides continuous visibility into operating conditions: input voltage (useful for diagnosing utility power quality issues), output voltage regulation, percentage load (critical for avoiding overload conditions that trigger UPS shutdown), battery state of charge, and estimated minutes remaining on battery. The audible alarm (user-configurable volume) distinguishes between on-battery operation (intermittent beep), low battery (rapid beep), and overload/fault conditions (continuous tone), allowing remote identification of UPS state without visual access to the display.

Standards Compliance and Application Fit: UL 1778 listing certifies the CP2000PFCRM2U for use in commercial and light-industrial installations; FCC Part 15 Class B compliance limits conducted and radiated emissions, making the unit suitable for office environments and residential-adjacent installations where Class A industrial limits would be insufficient. Energy Star certification confirms efficiency targets for UPS systems, important for facilities tracking LEED or Green Globes sustainability metrics. RoHS compliance ensures restriction of hazardous substances, simplifying disposal and recycling at end of service life. The true sine wave output topology and active PFC compatibility make this UPS the correct choice for modern IT loads: enterprise NVRs with 80 Plus certified power supplies, managed PoE switches (Cisco, Ubiquiti, Netgear, etc.), fiber media converters, access control panels with switched-mode supplies, VoIP phone systems, and rack-mount video encoders. Avoid using this UPS for motor-driven loads (fans, pumps) or legacy equipment with ferro-resonant transformers; the sine wave inverter is optimized for resistive and power-factor-corrected loads, not inductive reactance. For installations requiring remote monitoring—multiple equipment closets, rooftop installations, or unstaffed remote sites—budget for the optional Remote Network Management Card or Cloud Monitoring Card; these enable SNMP traps to network management systems, email alerts on power events, and safe shutdown integration with NVR and server operating systems to prevent filesystem corruption during extended outages.

Specifications
Product Type: UPS (Uninterruptible Power Supply)
Series: PFC Sinewave
Form Factor: Rackmount 2U
Mounting: 19-inch EIA Rack
Capacity VA: 2000 VA
Capacity Watts: 1200 W
Output Waveform: Pure Sine Wave
Topology: Line Interactive with AVR
Input Voltage: 120 VAC (82-144 VAC range)
Output Voltage: 120 VAC ± 5%
Input Frequency: 57-63 Hz
Output Power Factor: 0.6
Outlets: 8 x NEMA 5-20R (battery backup + surge)
Power Input: NEMA 5-20P plug, 6 ft cord
Runtime Half Load: 9 minutes (600W)
Runtime Full Load: 2.2 minutes (1200W)
Battery Type: Sealed Lead-Acid
Battery Configuration: 2 x 12V/9Ah
Battery Replacement: Hot-swappable, user-replaceable
Surge Suppression: 1500 Joules
Data Line Protection: RJ45 10/100/1000 Ethernet
Management Ports: USB, Serial DB9 (1 dry contact relay), SNMP slot (card optional)
Display: Multifunction color LCD
Dimensions: 17.05 x 3.39 x 10.79 in (W x H x D)
Weight: 28.68 lb
Operating Temperature: 32-104°F (0-40°C)
Certifications: UL1778, FCC Class B, RoHS, Energy Star
Warranty: Manufacturer Warranty
Color: Black
Type: UPS
Form Factor: 2U
Mount Type: Rack
Cable Category: PFC Sinewave UPS Systems
Battery: 2 x 12V/9Ah
Operating Temp: 32-104°F (0-40°C)
Standards: UL1778, FCC DOC Class B, RoHS, Energy Star
Upc: Not stated on page
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources