2N 01700-001 Indoor Flush Mount Box
The 2N 01700-001 is a purpose-built flush-mount enclosure designed to integrate 2N IP intercom and communication equipment into wall surfaces with a clean, integrated appearance. Unlike surface-mount boxes that protrude visibly, this flush housing sits recessed into the wall cavity, preserving the architectural finish while providing robust mechanical protection for your intercom hardware. It is a standard component in modern access control and visitor management deployments across commercial, institutional, and multi-tenant residential buildings.
Key Features
- Flush-mount form factor: Sits recessed into wall cavity rather than protruding — eliminates visual clutter in lobbies, corridors, and reception areas where aesthetic consistency matters.
- Compact footprint — 126mm × 186mm × 39mm: Fits standard wall cavities and tight spaces without requiring structural modification. Depth of 39mm (1.54 inches) is shallow enough for most internal wall stud spacing.
- Lightweight at 0.42 kg (0.93 lbs): Easy single-person installation; reduces load on wall anchors in hollow-core or composite wall substrates.
- Durable plastic construction: Resists corrosion and minor impact — appropriate for indoor institutional settings where metal enclosures can mark or dent adjacent surfaces.
- Operating temperature range -40°C to 60°C (-40°F to 140°F): Handles temperature swings in mechanical rooms, stairwells, and non-climate-controlled spaces without degradation. Wide range ensures stability in facilities with seasonal variation or inconsistent HVAC coverage.
- 2N IP intercom ecosystem compatibility: Designed as a native mounting solution for 2N IP endpoints and control modules — mechanical fit, electrical integration, and cable routing are pre-engineered. Simplifies commissioning versus adapting generic enclosures.
Integration & Compatibility
The 01700-001 is engineered specifically for the 2N IP intercom product family and related IP communication hardware. Verify your specific endpoint dimensions and connector layout against the enclosure interior before ordering — 2N publishes detailed installation guides with integration diagrams. If you are deploying a PoE network switch to power intercom endpoints, confirm your switch can supply the necessary budget; the enclosure itself is passive and requires no power.
Mounting & Installation Considerations
Flush-mount installation requires access to wall cavity during or after drywall installation. This makes the 01700-001 well-suited for new construction or retrofit projects where wall openings are feasible. In retrofit scenarios on finished walls, consider whether cutting a rectangular opening and patching around the enclosure is acceptable — surface-mount alternatives may be faster if wall surgery is not practical. The shallow depth means it will not accommodate very thick cable bundles; plan cable runs and terminations carefully.
When to Choose a Different Model
If your installation requires a surface-mount appearance — for example, mounting over existing finished walls without cutting — look for 2N surface-mount box variants in the same product line. If operating temperature extremes exceed -40°C to 60°C, or if you need IP-rated (water/dust) protection for semi-outdoor or exposed areas, consult 2N's outdoor-rated enclosure options.
Frequently Asked Questions
Q: Does the 2N 01700-001 require power?
A: No. The enclosure is a passive mounting housing. Power is supplied directly to the intercom endpoint or module installed inside it, typically via PoE from a network switch or a dedicated power supply routed through the wall cavity.
Q: Can the 01700-001 be mounted on a surface instead of flush into a wall?
A: It is designed as a flush-mount (in-wall) enclosure. Surface-mount installation is not recommended and may compromise cable integrity or hardware fit. For surface mounting, consult 2N's surface-mount box product line.
Q: What is the interior volume or available space for cable termination?
A: Exact interior dimensions and cable routing diagrams are provided in the 2N installation documentation specific to your endpoint model. Contact the integrator technical team or reference the endpoint datasheet for enclosure compatibility details.
Q: Does the 01700-001 come with a mounting template or trim ring?
A: Refer to the 2N installation guide for your specific endpoint. Trim rings, gaskets, and templates are often supplied separately or as part of endpoint kits. Verify inclusions with your equipment specification before site work begins.
Q: Is the 01700-001 suitable for outdoor or semi-outdoor installation?
A: No. Operating temperature range supports indoor institutional environments. For semi-outdoor or exposed mounting, 2N manufactures IP-rated outdoor enclosures. Verify outdoor ratings before deployment in weather-exposed locations.
Q: How is cable entry managed — are there knockouts or pre-drilled ports?
A: Refer to the 2N installation documentation for your specific intercom endpoint. Cable entry design and routing specifications are detailed in endpoint-specific guides. Plan wire paths and conduit routing during wall layout.
Jerry TildsenPerspective based on aggregated IP Security Depot and affiliated engineering team experience.
The 2N 01700-001 is straightforward hardware: a passive in-wall mounting enclosure sized to accommodate 2N IP intercom endpoints in commercial and institutional deployments. At 126mm × 186mm × 39mm, it slots into standard wall cavities without structural rework. The shallow 39mm depth is the key differentiator — it fits where thicker surface-mount boxes would protrude into circulation spaces or look out of place in modern office environments.
Technical Highlights:
- Operating range -40°C to 60°C: Wide thermal tolerance means this enclosure will not fail in unheated mechanical rooms, stairwells, or facilities with seasonal swing. Real value if your site has areas without year-round climate control.
- 39mm depth: Fits standard interior wall studs (typically 16" on center) without requiring cavity enlargement or framing modification. In retrofit, confirm wall cavity depth before committing to a hole.
- Plastic construction at 0.42 kg: No corrosion risk, and light enough for one installer to handle and position. Metal enclosures can mark adjacent surfaces — plastic eliminates that problem in high-traffic corridors or lobbies.
Deployment Considerations:
- Flush-mount is only practical during new construction or controlled retrofit where cutting a wall opening is acceptable. On existing finished walls, the time and patching cost may favor a surface-mount alternative.
- Cable routing discipline matters. The shallow depth means thick bundles or sharp bends during termination can damage insulation or create stress points. Plan your wire paths and conduit runs before installation.
- Verify endpoint dimensions against this enclosure's interior cavity using 2N's installation guide for your specific intercom model — mechanical fit is not universal across the entire 2N product family.
Deploy the 01700-001 in new-construction office lobbies, corporate campuses, healthcare facilities, and multi-tenant residential buildings where architectural aesthetics matter and wall access is available. Skip it for retrofit surface mounting or outdoor semi-protected exposures — different 2N enclosures exist for those scenarios.