Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: RLNK-SW620R
UPC: 656747179259
Condition: New
Write a Review 46% OFF

Middle Atlantic 20A Rackmount PWR Switch - RLNK-SW620R

Middle Atlantic RLNK-SW620R 20A Rackmount Power Distribution UnitOverviewThe Middle Atlantic RLNK-SW620R is a 1U rackmount power distribution unit bui…

$1,346.00 $730.99 SAVE $615
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Middle Atlantic 20A Rackmount PWR Switch - RLNK-SW620R

$1,346.00
$730.99

Overview

SKU: RLNK-SW620R
UPC: 656747179259
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Middle Atlantic RLNK-SW620R 20A Rackmount Power Distribution Unit

Overview

The Middle Atlantic RLNK-SW620R is a 1U rackmount power distribution unit built for AV, security, and IT rack environments where controlled startup sequencing and two-stage surge protection are non-negotiable. At 20A with a single-circuit layout, it delivers straightforward, reliable power management without the complexity overhead of full per-outlet metering — the right call for mid-density racks where you need protection and sequencing but not granular outlet-level analytics. Part of the broader Middle Atlantic power and rack solutions line, the RLNK-SW620R sits in the sweet spot between basic strip PDUs and enterprise-grade intelligent units.

Key Features

  • Outlet Sequencing: Startup sequencing staggers device power-on across the rack, eliminating the inrush current spike that trips breakers and stresses UPS units during system boot. For racks with NVRs, managed switches, and servers, this alone justifies the step up from a passive strip.
  • 2-Stage Surge Protection: Dual-stage filtering handles both fast transient spikes and slower voltage swells — a single-stage MOV alone won't catch everything. Critical in installations near HVAC compressors, elevator motors, or outdoor camera runs where line noise is a daily reality.
  • Seismic Rating: Verified to seismic performance standards, making the RLNK-SW620R a documented fit for government, healthcare, and education deployments where seismic compliance is a formal bid requirement. Not a spec you need until you need it — and then it's the only spec that matters.
  • 1U Rackmount / 2 Mounting Points: Standard 1RU form factor mounts cleanly in any 19-inch rack with two mounting points for secure chassis engagement. Keeps the footprint minimal — one rack unit leaves room for the equipment it's powering.
  • Single Circuit Architecture: One 20A circuit keeps load management straightforward. Size your connected load to stay under 80% continuous draw (16A) per standard electrical practice — the single circuit makes that math simple.
  • ETL Listed / FCC: ETL listing confirms the unit has been independently tested to applicable safety standards. FCC compliance covers conducted and radiated emissions — relevant if you're integrating into an RF-sensitive environment alongside wireless access points or two-way radio infrastructure.

Integration and Compatibility

The RLNK-SW620R fits standard 19-inch equipment racks and pairs naturally with Middle Atlantic's rack enclosures and UPS platforms. The single-circuit 20A design is compatible with standard NEMA 5-20 branch circuits — verify your panel breaker matches before deployment. For installations requiring per-outlet switching or remote monitoring, review the broader intelligent PDU family before specifying this model; the RLNK-SW620R trades those capabilities for simplicity and a lower per-rack cost. Outlet control type 4 indicates switched outlet grouping — confirm outlet count and configuration against your rack load sheet prior to ordering.

Frequently Asked Questions

Q: Is the RLNK-SW620R seismic rated?

A: Yes. The RLNK-SW620R carries a seismic rating, making it suitable for deployments where seismic compliance is a documented requirement, such as government, healthcare, or California Title 24 projects.

Q: Does the RLNK-SW620R support outlet-level switching or remote monitoring?

A: The RLNK-SW620R provides outlet control (type 4) and sequencing but is not documented as a full remote-monitored PDU with per-outlet metering. If per-outlet remote control or SNMP monitoring is required, evaluate higher-tier models in the Middle Atlantic RackLink line.

Q: What surge protection does the RLNK-SW620R provide?

A: The unit uses 2-stage surge protection, which addresses both fast transient spikes and slower voltage events — more comprehensive than single-stage MOV designs common in basic PDUs.

Q: What circuit amperage does the RLNK-SW620R support?

A: The RLNK-SW620R operates on a single 20A circuit. Standard practice is to keep continuous load at or below 80% (16A) to avoid nuisance tripping.

Q: Is the RLNK-SW620R ETL listed?

A: Yes, the RLNK-SW620R is ETL listed and FCC compliant, confirming independent third-party safety testing and emissions compliance.

Eden Phillips
Eden Phillips

The RLNK-SW620R is the PDU I reach for when a rack needs sequencing and real surge protection but doesn't justify the cost of full per-outlet remote monitoring. The built-in startup sequencing is the spec that matters most on day one — it prevents the inrush current pile-up that trips branch breakers when you power a rack cold, and it's the difference between a clean boot and a 2 AM service call.

Technical Highlights:

  • Outlet Sequencing: Staggers device startup to eliminate inrush current spikes — directly reduces nuisance breaker trips during power restoration events in security and AV control rooms.
  • 2-Stage Surge Protection: Dual-stage design catches both fast transients and slower swells; single-stage MOV protection misses the slow-rise events that degrade sensitive electronics over time.
  • Seismic Rating: Documented seismic compliance on the RLNK-SW620R is a bid-qualifier, not a feature — it's what gets this unit onto the approved products list for government and healthcare projects without an RFI.

Deployment Considerations:

  • Single 20A circuit means all connected loads share one breaker — calculate your total rack draw and keep it under 16A continuous before specifying; if you're regularly pushing above that threshold, move to a dual-circuit model.
  • Outlet control type 4 indicates switched grouping, but verify outlet count and layout match your rack load plan before finalizing the order — Middle Atlantic publishes full outlet configuration details in the product datasheet.

Best fit for a security operations rack or AV control room where the priority is a clean, sequenced startup and proven surge filtering — and where per-outlet SNMP telemetry isn't in scope.

Specifications
Mount Type: Rack
Rack Units: 1 RU
Mounting Points: 2
Number Of Circuits: 1
Outlet Control Type: 4
Surge Protection Type: 2-Stage
Etl Listed: FCC
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources