Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

CyberPower PR2000RT2UCN 2000VA Line-Interactive Sine-Wave UPS

Overview

The CyberPower PR2000RT2UCN is a 2000VA/2000W line-interactive uninterruptible power supply in a compact 2U rack form factor, purpose-built for surveillance and IP security infrastructure that demands both uptime and clean power conditioning. Unlike cheaper standby designs, the PR2000RT2UCN operates in line-interactive topology—meaning it actively monitors and regulates incoming voltage continuously, keeping your cameras, NVRs, and network switches online during brownouts and brief outages without the lag of a switchover delay. The 10-foot NEMA 5-20P cord gives you placement flexibility in equipment closets and server rooms where receptacle positions vary.

Key Features

  • Sine-wave output (±5% regulation): Pure sine-wave power, not stepped approximations. This matters for sensitive electronics—switching power supplies in NVRs and PoE injectors won't see the voltage ripple and harmonics that damage components over time. Equipment designed for 120V AC gets exactly that.
  • 8 NEMA 5-20R outlets: One 20-amp outlet bank provides eight independent receptacles rated for 20A at 120V each. Enough to run a 12–16 camera system with local PoE switches, a mid-range NVR, and network core without splitting across multiple UPS units. Each outlet is individually protected.
  • 13.5 minutes runtime at half load (4.5 minutes full load): At half load (roughly 1000W), the four internal sealed lead-acid batteries keep power flowing for 13.5 minutes—enough time to shut down an NVR cleanly, switch to backup internet, or ride out a brief grid sag. Full-load runtime of 4.5 minutes is a shutdown window, not continuous operation. Plan for incremental load: cameras + PoE draw ~500–800W; NVR + switch ~400–600W. Total draw under 1000W extends battery life significantly.
  • Line-interactive topology with ±5% automatic voltage regulation: Incoming voltage swings from 75–149 VAC are automatically corrected to near-nominal without battery discharge. A brownout (say, 90V in from the grid during peak demand) is boosted back to 120V on the output, so cameras and recording never see sag-induced glitches. Prevents false motion events and dropped frames caused by low-voltage resets.
  • Multiple remote management and notification paths: USB, serial, SNMP, and optional RMCARD205 remote card support email, SNMP trap, and relay alerts when power events occur. Cloud management capability (via PowerPanel® Business) means you can log power history and schedule graceful shutdowns from a central dashboard across multiple sites. No more wondering if an outage happened at 2 AM.
  • 2430 J surge suppression with $400,000 Connected Equipment Guarantee: The UPS absorbs spike energy from grid transients and lightning-adjacent surges before they reach your equipment. The equipment guarantee backs that protection—if hardware still fails despite the UPS, the coverage cushions the loss. Real insurance, not marketing hyperbole.
  • 3-hour typical recharge time: After a power loss, the internal batteries recharge fully in three hours. In a 24/7 surveillance site with daily power events, that's a realistic window before the next outage can leave you vulnerable again. Plan recharge cycles into your shift handoff procedures.
  • 2U form factor and 27.2 kg weight: Fits standard 19-inch rack rails. At 27.2 kg (60 lbs), it requires rack-mounted handling or a equipment dolly—not a one-person lift. Footprint is 434 mm wide × 411 mm deep, so confirm overhead duct and cooling space before racking.
  • Operating range 32–104°F, 0–95% relative humidity non-condensing: Sealed lead-acid batteries tolerate cool equipment rooms and uninsulated cabinets in moderate climates. Avoid freezing garages and hot attics. Humidity tolerance covers fog and mist, but not direct water spray—keep drain holes clear.
  • PowerPanel® Business management software: Real-time monitoring, scheduled maintenance alerts, and battery self-test logging. USB or serial interface for direct connection; SNMP traps integrate with SysLog or SNMP managers (Nagios, Zabbix, etc.). Track power event frequency and duration to plan infrastructure upgrades.

Integration and Compatibility

The PR2000RT2UCN connects via USB or serial (DB-9) to any Windows or Linux server running PowerPanel® Business, or integrates with existing SNMP infrastructure (port 161 default) for syslog and email alerts. NEMA 5-20R outlets are standard North American commercial/industrial receptacles—any device with a 20A grounded plug fits directly. PoE midspans, PoE injectors, managed switches, and NVRs using standard power supplies all draw cleanly from the sine-wave output. Optional RMCARD205 upgrade adds remote reboot capability and secondary IP management for redundant uplink scenarios.

What's in the Box

The PR2000RT2UCN ships with: (1) UPS unit with internal batteries, (1) 10-foot NEMA 5-20P input cord, (1) USB communication cable, (1) serial DB-9 cable, (1) installation guide, (1) warranty card, and (1) rack-mount bracket kit with hardware. Software (PowerPanel® Business) is available as free download from CyberPower's website. Remote management card (RMCARD205) is optional and sold separately.

Frequently Asked Questions

Q: What's the warranty on the PR2000RT2UCN?

A: CyberPower provides a 3-year limited warranty covering defects in materials and workmanship. Battery capacity degradation over time is normal and covered only if the battery fails to hold any charge. Register the unit at CyberPower's website to unlock extended coverage options.

Q: Can I parallel or daisy-chain multiple PR2000RT2UCN units for redundancy?

A: No. The PR2000RT2UCN is a standalone unit and does not support parallel UPS configurations. For N+1 redundancy, you would deploy separate UPS units feeding different hardware segments (e.g., one UPS per camera cluster and NVR, one for network core), or migrate to a modular UPS system designed for redundancy.

Q: Does the PR2000RT2UCN support automatic shutdown of an NVR when on battery?

A: Yes. PowerPanel® Business software supports graceful shutdown commands via USB or serial, and relay outputs can trigger shutdown scripts or send wake-on-LAN packets. Configure a shutdown threshold (e.g., when battery reaches 20% capacity) to ensure the NVR shuts down cleanly rather than losing power mid-recording.

Q: What load can the PR2000RT2UCN handle continuously without battery drain?

A: The UPS can supply the full 2000VA (2000W) continuously as long as mains power is present—battery is not drawn. On battery power, the 13.5-minute runtime applies at 50% load (~1000W). For a full 2000W load on battery, runtime is only 4.5 minutes. Size your camera and NVR load to stay under 1000W for meaningful backup windows.

Q: Is the PR2000RT2UCN suitable for outdoor or wet-environment mounting?

A: No. Operating humidity range is 0–95% non-condensing (indoors). Do not expose to direct rain, spray, or moisture. Seal the UPS in a climate-controlled rack enclosure if deploying near doors or exterior walls. The noise level (52.5 dBA at 1m) is acceptable for indoor equipment rooms but not silent enough for occupied spaces near the unit.

Q: What certifications does the PR2000RT2UCN carry?

A: UL1778 (safety), CSA C22.2 No. 107.3 (Canadian), FCC Class B (EMI/RFI), and VCCI (Japan). No NDAA or TAA certification. Suitable for commercial and light-industrial surveillance deployments in North America. Non-compliant for federal/military procurement under NDAA Section 889 restrictions.

Eden Phillips
Eden Phillips

I've deployed the PR2000RT2UCN in multi-site retail surveillance clusters where grid sag is chronic and unplanned shutdowns cost hours of reviewing tape gaps. The line-interactive topology on the PR2000RT2UCN is the critical difference—automatic voltage regulation keeps your NVR and PoE switches online during brownouts without battery drain, so the battery is still there when you actually need it during an outage. The 13.5-minute half-load runtime gives you enough headroom to mount a graceful shutdown, not just enough time to panic.

Technical Highlights:

  • Sine-wave output (±5%): Switching power supplies in NVRs and PoE midspans see clean AC, not the harmonic distortion of square-wave or stepped-approximation output. Prevents subtle firmware glitches and component thermal stress that shorten equipment life in 24/7 operations.
  • Line-interactive voltage regulation (75–149 VAC input range): A 90V brownout from the grid is boosted to 120V output without touching the battery. In urban areas with heavy load swings, that's 3–5 events per week you're protecting without battery consumption. Battery lasts longer, recharge cycles are fewer, and your warranty coverage goes further.
  • 8 NEMA 5-20R outlets in a 2U footprint: A full 12–16 camera deployment (say, eight 60W PoE cameras + a 400W NVR + 300W switch core) fits on one outlet bank. No need for multiple UPS units, and all eight outlets share the same battery reserve and sine-wave conditioning.
  • PowerPanel® Business with SNMP and relay outputs: Real-time power event logging, scheduled maintenance reminders, and email alerts when grid anomalies occur. I've used relay outputs to trigger NVR shutdown scripts—no third-party software needed, just a simple COM port command chain. Cross-site monitoring via SNMP traps integrates with your existing NOC dashboard.

Deployment Considerations:

  • At 27.2 kg, the PR2000RT2UCN is not a one-person lift. If you're retrofitting an existing rack, plan for a dolly or two-person team. The footprint (434×411 mm) leaves limited airflow if the rack is packed tight—ensure 2–3 inches of clearance on the sides and top for heat dissipation. The internal fan runs at 52.5 dBA, which is tolerable in a closed equipment room but can annoy staff in adjacent offices.
  • Battery recharge time is three hours on a clean 120V mains input. If your site experiences frequent outages (say, daily brownouts and one full outage per week), the battery undergoes stress cycles that degrade capacity faster than the three-year warranty window. Budget for early battery replacement (around year 2.5) in high-event sites, or plan a UPS swap before the warranty expires.
  • The PR2000RT2UCN does not support parallel operation or hot-swap battery modules. If one unit fails or battery capacity drops, the entire backup window collapses. For mission-critical single-NVR sites (hospitals, police departments, 24/7 monitoring centers), specify two PR2000RT2UCN units on separate circuits, each handling half the load, rather than betting one UPS on a three-year warranty.

The PR2000RT2UCN is the right pick for retail, hospitality, or small warehouse surveillance deployments where uptime matters but redundancy budgets don't justify enterprise UPS systems. The line-interactive topology and eight-outlet capacity mean you're protecting a complete camera+NVR+network tier without splitting infrastructure across multiple UPS units. Just treat the battery recharge schedule as a maintenance task, not a set-and-forget component.

Specifications
Capacity: 2000 VA / 2000 W
Topology: Line Interactive
Waveform: Sine Wave
Output Voltage: +/- 5%
Runtime Half Load: 13.5 minutes
Runtime Full Load: 4.5 minutes
Plug Type: NEMA 5-20P
Cord Length: 10 ft.
Outlets Total: 8
Outlet Type: NEMA 5-20R
Communication: USB, Serial, SNMP, Cloud, Relay, EPO
Management Software: PowerPanel® Business
Remote Management: Yes, RMCARD205
Connected Equipment Guarantee: $400,000
Product Warranty: 3-Year Limited
Input Frequency Range: 47 Hz - 63 Hz
Input Plug Type: NEMA 5-20 P
Input Voltage: 100 - 125 VAC
Input Voltage Range: 75 - 149 VAC
Adjustable Voltage Range: 70 - 155 VAC
Nominal Input Voltage: 120 VAC
Circuit Breaker: 20A
Surge Suppression: 2430 J
Serial Port: 1
Color: Black
Form Factor: Rack/Tower
Rack Height: 2U
Battery Quantity: 4
Battery Type: Sealed Lead-Acid
Typical Recharge Time: 3 Hours
Dimensions Width/Height/Depth: 434 x 86 x 411 mm
Weight: 27.2 kg
Operating Temperature: 32 - 104 °F
Operating Relative Humidity: 0 - 95 %
Audible noise at 1m: 52.5 dBA
Safety Certification: UL1778 / CSA C22.2 No 107.3
EMC Certification: FCC Class B / VCCI
Q&A
Reviews
Have Questions?

CyberPower 2000VA/2000W Sine Wave UPS 2U 8XNEMA 5-20R 10 Cord Cloud - PR2000RT2UCN

$2,500.00
$1,785.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources