Vertiv 15KVA APS MAX 15KVA 5M BAT - AS5C0NCWGNNXLKB
15kVA uninterruptible power supply (UPS) designed to provide critical power protection for sensitive equipment in commercial and industrial
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv AS5B0NCVGNNXLKB is a lithium-ion battery module designed for the APS MAX UPS platform, rated for 10KVA systems with a 15KVA scalable path. Where lead-acid strings demand replacement every 3–5 years and struggle in warm equipment rooms, this LiFePO₄-based module delivers a rated service life of up to 10 years and is designed to hold performance at elevated temperatures rather than derating — a meaningful difference in dense data center rows, telecom cabinets, and industrial control rooms where ambient heat is a constant pressure. The AS5B0NCVGNNXLKB ships as a single battery string weighing approximately 46 lbs, making it manageable for two-person installation without mechanical lifting equipment in most rack environments. Browse the full Vertiv power protection catalog for compatible UPS platforms and accessories.
The AS5B0NCVGNNXLKB is designed for the Vertiv APS MAX UPS platform. Confirm compatibility with your specific APS MAX model and configuration before ordering — lithium battery modules are not universally interchangeable across UPS families, and the BMS communication protocol must match the UPS controller's expectations. If you are evaluating this module as part of a new UPS deployment, consult the APS MAX product documentation for maximum battery string count and cabinet configuration requirements. For environments running parallel UPS systems or extended runtime configurations, verify that your UPS systems installation supports the number of strings required to meet your runtime target at full load. Pair with a managed PDU downstream for outlet-level load monitoring that complements the BMS data from this module. For planning runtime budgets across multiple critical loads, review our UPS runtime planning guide before sizing battery strings.
Q: What is the warranty on the AS5B0NCVGNNXLKB?
A: The AS5B0NCVGNNXLKB carries a 5-year manufacturer warranty covering both the UPS and the battery module.
Q: How long does the AS5B0NCVGNNXLKB take to recharge after a full discharge?
A: Recharge time is under 4.5 hours from a full discharge to full capacity.
Q: Why does this module use LiFePO₄ chemistry instead of standard lithium-ion?
A: LiFePO₄ (Lithium Iron Phosphate) is the most thermally stable lithium chemistry, significantly reducing thermal runaway risk compared to NMC or NCA cells. It is the standard choice for UPS and energy storage applications where safety in enclosed spaces is a requirement.
Q: How does the AS5B0NCVGNNXLKB perform in warm environments?
A: The module is rated for better performance at higher temperatures compared to lead-acid alternatives, which can lose substantial capacity as ambient temperature rises. This makes it better suited for industrial, telecom, and other installations where ambient heat is a factor.
Q: What does the Advanced BMS do on this battery module?
A: The onboard Battery Management System monitors at the individual cell level, providing granular visibility into cell health. This enables predictive maintenance — identifying degrading cells before they affect string performance — rather than relying on aggregate voltage readings that can mask early-stage failures.
Q: How heavy is a single battery string for the AS5B0NCVGNNXLKB?
A: Each battery string weighs approximately 46 lbs, which is within standard two-person lift limits for most installations. Multi-string configurations should account for horizontal slide-in rack positioning to avoid overhead lifts.

The spec that changes the conversation on the AS5B0NCVGNNXLKB is the cell-level BMS monitoring. Most battery modules report at the string level — you get an aggregate voltage and a health percentage, and you're flying blind on which cells are actually drifting. Cell-level visibility means you can pull maintenance data, trend it over time, and schedule a replacement before you discover the problem during an actual outage. That's the operational difference between reactive and predictive power infrastructure management.
Technical Highlights:
Deployment Considerations:
The AS5B0NCVGNNXLKB is the right call for critical infrastructure deployments — edge data centers, industrial control rooms, unmanned telecom sites — where battery replacement logistics are expensive and thermal environment cannot be fully controlled. The combination of 10-year service life and cell-level BMS intelligence eliminates the two most common failure modes in extended-runtime UPS deployments: unexpected capacity degradation and surprise end-of-life failures.