Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv GL36WMCMM-W-SC-00-00 19U Wall-Mount Network Enclosure

The Vertiv GL36WMCMM-W-SC-00-00 is a configurable wall-mount rack enclosure from the Vertiv cabinet and enclosure line, available in 12U, 19U, and 25U heights to match the equipment density of small IDF closets, edge compute nodes, or branch office network rooms. The Winter White finish suits environments where aesthetics matter — open offices, lobbies, or clean-room spaces where a black cabinet would stand out.

Overview

Wall-mount enclosures solve a specific problem: you need structured, lockable housing for network or AV equipment but lack the floor space for a full-height rack. The GL36WMCMM-W-SC-00-00 addresses that with a 19-inch-compatible bay in a bolted wall-mount form factor. Three height options — 24-inch (12U), 36-inch (19U), and 48-inch (25U) — let you right-size the cabinet to the actual equipment count, avoiding oversized enclosures that waste wall real estate and complicate cable routing.

Key Features

  • Three Height Configurations (12U / 19U / 25U): Selecting the right U-count prevents the common mistake of buying oversized cabinets — a 12U unit keeps a small IDF tidy and accessible; a 25U unit handles denser edge deployments with room for patch panels, switches, and UPS gear without crowding.
  • SEAL Combo Access Control: The SEAL Combo lock provides keypad-plus-key dual-mode access, so you can maintain physical security without issuing keys to every technician — a meaningful operational advantage in multi-tenant buildings or facilities with rotating contractors. GL36WMCMM-W-SC-00-00 also supports Swing Handle and SEAL Electronic options if your site uses electronic access logging.
  • Door Options — Plexi, Mesh, or Solid: A plexi door lets you visually confirm indicator light status without opening the cabinet — useful for quick checks in secured comms rooms. Mesh doors maximize passive airflow for heat-sensitive equipment. Solid doors provide the cleanest appearance and best dust control for office-facing installs.
  • Active Fan Airflow Option: Where passive convection isn't enough — dense PoE switch stacks, UPS units, or high-wattage edge servers — the fan airflow configuration moves heat out actively. Pairing this with a mesh door maximizes thermal performance.
  • Cable Bar and Clear Management Options: Structured cable management inside the enclosure keeps patch runs organized and reduces troubleshooting time. A cable bar provides horizontal dressing points; the Clear option adds visibility so you can trace runs without pulling cables.
  • Winter White Color: Where a black enclosure would visually clash — open-plan offices, retail back-of-house, medical reception areas — the Winter White finish integrates cleanly with architectural finishes without requiring custom painting or shrouding.

Integration and Compatibility

The 19-inch-compatible interior accepts standard EIA-310 rack equipment — switches, patch panels, small NVRs, UPS units, and AV gear. Pair with a compatible PoE network switch to consolidate power and data in a single lockable enclosure. Vertiv wall-mount enclosures are engineered to accept Vertiv-branded PDUs and accessory rails, so expansion within the enclosure stays modular.

Frequently Asked Questions

Q: What U heights are available for the GL36WMCMM-W-SC-00-00?

A: Three heights are available: 24-inch (12U), 36-inch (19U), and 48-inch (25U). Select based on your equipment count, leaving at least 2U of spare capacity for airflow and future additions.

Q: What access control options does this enclosure support?

A: The GL36WMCMM-W-SC-00-00 supports Swing Handle, SEAL Combo (keypad + key), and SEAL Electronic configurations. SEAL Combo is the standard for environments requiring audit-free dual-mode access; SEAL Electronic suits sites with access logging requirements.

Q: Can I add active cooling to this cabinet?

A: Yes — the enclosure is configurable with a fan airflow option for environments where passive convection is insufficient. Pairing fan airflow with a mesh door yields the best thermal performance.

Q: What door types are available?

A: Plexi (clear acrylic for visual status checks), Mesh (maximum passive airflow), and Solid (cleanest appearance, best dust control). Door type selection should be driven by thermal load and environment.

Q: Does this enclosure accept standard 19-inch rack equipment?

A: Yes. The interior is EIA-310 compatible and accepts standard 19-inch rack-mount equipment including switches, patch panels, NVRs, and UPS units.

Eden Phillips
Eden Phillips

When I spec wall-mount enclosures for IDF closets and edge nodes, the GL36WMCMM-W-SC-00-00 stands out specifically because of its SEAL Combo access control — most budget wall-mounts ship with a basic cam lock that any common key opens. The SEAL Combo's dual-mode keypad-plus-key design means you can hand a temp contractor a code without cutting a physical key, then revoke it by changing the combination. That's a real operational win on multi-tenant floors.

Technical Highlights:

  • Three U configurations (12U / 19U / 25U): Right-sizing the enclosure to actual rack density prevents the airflow dead zones that form at the top of an oversized cabinet — dead zones trap heat even when you add a fan.
  • Fan airflow + mesh door pairing: Fan-equipped units move air directionally; a mesh door removes the exhaust restriction that a solid or plexi door creates. If you're housing a dense PoE switch or a small UPS, spec both together.
  • Cable Bar option: Horizontal cable dressing inside a wall-mount enclosure is consistently the first thing skipped during install and the first thing regretted during troubleshooting. The Cable Bar option bakes it in at the factory rather than retrofitting it with zip ties.

Deployment Considerations:

  • Wall-mount load ratings depend on the wall substrate and anchor selection — confirm the mounting surface (concrete, metal stud, wood stud) before finalizing the U-count. A fully populated 25U unit is substantially heavier than a 12U unit and may require through-wall blocking.
  • The Winter White finish is specific to this configuration; if the enclosure will share a wall with standard Black Vertiv or third-party gear, confirm color consistency before ordering — mismatched enclosures in a visible comms room draw facility manager complaints.

This enclosure is the right call for branch office IDF closets, open-office network rooms, and retail back-of-house AV/network consolidation where floor space is constrained and physical security requirements exceed what a basic locking patch panel can provide.

Specifications
Height: 24" (12U)36" (19U)48" (25U)
Color: BlackWinter White
Door: PlexiMeshSolid
Access Control: Swing HandleSEAL ComboSEAL Electronic
Airflow: NoneFan
Cable Management: NoneCable BarClear
freight: 565.40
Q&A
Reviews
Have Questions?

Vertiv WM Premium 19UX24X32 Gray - GL36WMCMM-W-SC-00-00

$2,277.00
$1,547.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources