Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv GL36WMCMM-B-SC-00-00 Wall-Mount Network Enclosure Cabinet

Overview

The Vertiv GL36WMCMM-B-SC-00-00 is a configurable wall-mount rack enclosure built for network equipment, patch panels, and edge compute gear in spaces where a full floor-standing cabinet isn't practical — branch offices, server closets, retail back-of-house, and security equipment rooms. Available in three height variants (24"/12U, 36"/19U, and 48"/25U), it gives system designers the flexibility to right-size racking capacity to the actual equipment load without overbuilding. Part number GL36WMCMM-B-SC-00-00 (also searched as GL36WMCMM B SC 00 00) represents the Black colorway with SEAL Combo access control in this Vertiv enclosure series.

The enclosure ships in a genuinely modular configuration matrix: door type, access control method, airflow, and cable management are all selectable — which means the same base enclosure can serve a locked IT closet with active thermal management or an open equipment room with passive airflow and a simple swing handle. That range of options makes this a practical stock item for integrators who deploy across varied site types.

Key Features

  • Three height options — 12U, 19U, and 25U: The 12U (24") suits single-switch or small patch panel deployments; the 19U (36") handles mid-density edge nodes with room to grow; the 25U (48") accommodates fuller equipment stacks without moving to a floor unit. Matching enclosure height to actual rack density prevents paying for unused vertical space — and avoids the opposite problem of having to add a second enclosure mid-project.
  • Door options — Plexi, Mesh, and Solid: Plexi gives you visual equipment status checks without opening the cabinet — useful in unmanned equipment rooms. Mesh maximizes passive airflow for heat-sensitive environments. Solid provides the cleanest appearance for customer-visible or reception-area installations. Choosing the wrong door for a high-heat environment is a common field mistake; if active gear is packed into this cabinet, mesh or paired with the fan option is the right call.
  • Access control — Swing Handle, SEAL Combo, and SEAL Electronic: Swing Handle suits low-security utility spaces. SEAL Combo adds a keyed combination lock for sites that need access accountability without card infrastructure. SEAL Electronic steps up to electronic credential control — relevant on sites that already run an access control system and want enclosure access logged alongside door events. The GL36WMCMM-B-SC-00-00 specifically ships with SEAL Combo, which is the most commonly deployed middle tier.
  • Airflow — None or Fan: Passive (no fan) works for patch panels, fiber management, and low-power switching gear. The fan option matters when you're mounting PoE switches, compute nodes, or dense media converters that generate meaningful heat in an enclosed space. Fan-equipped cabinets in wall-mount applications should be paired with mesh or vented doors to give the thermal path somewhere to go — a common oversight on first-time enclosure installations.
  • Cable management — None, Cable Bar, and Clear: The Cable Bar option provides horizontal routing attachment points that keep patch cables organized and service loops contained — critical on 19U-and-up configurations where cable clutter can restrict airflow and complicate moves, adds, and changes. Clear cable management offers a transparent routing solution that preserves visual access to cable runs. Skipping cable management on a dense 25U wall-mount almost always becomes a labor problem at the first equipment change.
  • Color — Black or Winter White: Black integrates into standard equipment room aesthetics and conceals dust. Winter White suits deployments in finished office environments where an all-black enclosure would stand out against light-colored walls — a real consideration for enclosures installed in administrative or reception spaces.

Integration and Compatibility

The GL36WMCMM-B-SC-00-00 follows standard 19-inch EIA rack spacing, making it compatible with off-the-shelf network switches, patch panels, fiber management trays, and 1U/2U accessory shelf hardware from any vendor. The three height variants accommodate the vast majority of edge and branch equipment stacks without modification. Wall-mount enclosures of this type are standard infrastructure in structured cabling and network rack deployments — the SEAL Combo access control variant is particularly common in multi-tenant and managed service provider environments where per-site access accountability is required.

If the deployment includes active equipment generating significant heat, plan airflow from the start: select the fan airflow option, choose a mesh or vented door, and confirm the wall anchor load rating against the fully-loaded cabinet weight — wall stud placement and anchor type are installation variables outside the enclosure spec that determine whether a wall-mount unit stays mounted under real-world load.

Frequently Asked Questions

Q: What rack unit capacities are available for the GL36WMCMM-B-SC-00-00?

A: Three height options are available: 24 inches (12U), 36 inches (19U), and 48 inches (25U). Choose based on your actual equipment count plus a growth margin — undersized wall-mount enclosures are difficult to expand once installed.

Q: What door types are available, and how do I choose?

A: Plexi, Mesh, and Solid doors are available. Plexi allows visual status checks without opening the cabinet. Mesh provides maximum passive airflow for heat-generating equipment. Solid is best for aesthetics in customer-visible spaces. If you're installing active switching or compute gear, Mesh is the safest default.

Q: What does SEAL Combo access control mean on the GL36WMCMM-B-SC-00-00?

A: SEAL Combo is a keyed combination lock mechanism that provides physical access control without requiring card reader or electronic credential infrastructure. It is a step above a basic swing handle and is commonly deployed in branch offices and remote equipment rooms where access accountability is needed but full electronic access control isn't in scope.

Q: Does this enclosure support active cooling?

A: Yes — a fan airflow option is available. If your equipment load generates significant heat, specify the fan option and pair it with a mesh or vented door to provide a clear thermal exhaust path. The passive (no fan) configuration is appropriate for low-heat loads like patch panels and fiber management hardware.

Q: Is the GL36WMCMM-B-SC-00-00 compatible with standard 19-inch rack equipment?

A: Yes. The enclosure uses standard 19-inch EIA rail spacing, compatible with switches, patch panels, fiber trays, UPS units, and other 1U–2U rack-mount hardware from any manufacturer that follows EIA-310 rack standards.

Q: What cable management options are available?

A: Three options: None, Cable Bar, and Clear. Cable Bar provides horizontal routing points for patch cable organization. Clear offers transparent routing for visibility into cable runs. For any deployment at 19U or larger, cable management is strongly recommended — unmanaged patch cables in a dense wall-mount enclosure restrict airflow and complicate any future equipment changes.

Marty Allison
Marty Allison

The GL36WMCMM-B-SC-00-00 is one of those enclosures I recommend regularly for branch office and security equipment room deployments precisely because of its configuration range — you're not locked into a single door type or access control tier. The SEAL Combo lock on this specific SKU hits the right balance for most managed service environments: it's more accountable than a swing handle but doesn't require card reader infrastructure that a remote site may not have.

Technical Highlights:

  • Three height variants (12U/19U/25U): Wall-mount enclosures are hard to expand after installation — picking the 19U (36") or 25U (48") variant at initial deployment costs less than a second enclosure and a return visit six months later when the equipment stack grows.
  • Fan airflow option: A wall-mount enclosure with no airflow and a solid door is a heat trap for anything drawing meaningful wattage. The fan option paired with a mesh door is the only configuration I'd specify for a cabinet holding PoE switches or edge compute nodes.
  • SEAL Combo vs. SEAL Electronic: SEAL Electronic exists in this product family for sites that need enclosure access logged in their access control system. If you're running Lenel, Genetec, or any credential-based ACS at the site, the Electronic tier is worth the upgrade — otherwise SEAL Combo is the right call.

Deployment Considerations:

  • Wall anchor load rating is the first thing to verify before installation — the anchors and studs, not the enclosure, are the failure point in fully loaded wall-mount cabinets. Confirm the wall construction type and anchor specification against the expected fully-loaded weight.
  • If you specify the fan option, also specify a mesh or vented door — a fan pushing air inside a sealed solid-door enclosure provides minimal thermal benefit and adds unnecessary noise.

This enclosure is the right fit for security equipment rooms and branch IT closets where floor space is constrained, access accountability is required, and the equipment load is predictable — particularly managed service deployments where SEAL Combo provides per-site access control without per-site card reader infrastructure.

Specifications
Height: 24" (12U)36" (19U)48" (25U)
Color: BlackWinter White
Door: PlexiMeshSolid
Access Control: Swing HandleSEAL ComboSEAL Electronic
Airflow: NoneFan
Cable Management: NoneCable BarClear
freight: 565.40
Q&A
Reviews

Vertiv WM Premium 19UX24X32 Gray - GL36WMCMM-B-SC-00-00

$2,277.00
$1,718.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources