Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv GL36WMCMP-W-SH-00-00 19U Wall Mount Network Cabinet with Fan Airflow

Overview

The Vertiv GL36WMCMP-W-SH-00-00 is a 19-inch wall mount enclosure built for network closets, server rooms, and edge deployments where floor space is unavailable or restricted. Configurable across three depth profiles — 24-inch (12U), 36-inch (19U), and 48-inch (25U) — this cabinet scales to match the actual equipment density of your installation rather than forcing you to over-specify hardware from the start. The Winter White color finish makes it a practical fit for office interiors, healthcare corridors, and light-industrial environments where an all-black rack would visually stand out. Whether you are consolidating patch panels and switches in a telecom closet or deploying edge compute gear in a retail backroom, the GL36WMCMP-W-SH-00-00 delivers the structural configuration flexibility that fixed-depth enclosures cannot. Explore the full Vertiv enclosure and infrastructure catalog for complementary rack and power options.

Key Features

  • Three Height Configurations (12U / 19U / 25U): The 24-inch, 36-inch, and 48-inch depth options correspond to 12U, 19U, and 25U usable rack space respectively. Choosing the right depth at procurement avoids the common mistake of under-sizing and hitting a capacity ceiling six months after installation — especially relevant in telecom closets where patching density climbs faster than anticipated.
  • Fan Airflow Option: Active fan cooling addresses the primary failure mode of wall mount cabinets in enclosed spaces — heat buildup from densely loaded switches and patch panels. If your equipment load exceeds passive convection limits (a realistic scenario once you exceed 60–70% fill with 1GbE PoE switches), specifying the fan configuration keeps inlet temperatures within manufacturer operating ranges without requiring a dedicated CRAC unit.
  • Three Door Configurations (Plexi / Mesh / Solid): The Plexi door lets technicians visually confirm link lights and LED status without opening the enclosure — practical for spaces shared with non-IT staff. Mesh doors maximize passive airflow when active fans are not specified. Solid doors provide the cleanest appearance for executive-area or customer-facing installations where exposed equipment is undesirable.
  • Winter White Color Finish: The Winter White variant integrates with office and healthcare environments where standard black cabinetry is a visual mismatch. For compliance-sensitive environments like patient care areas or call centers with strict aesthetic standards, color alignment is a real procurement consideration, not a cosmetic afterthought.
  • Three Access Control Options (Swing Handle / SEAL Combo / SEAL Electronic): The SEAL Electronic lock option supports audit-trail accountability — critical in multi-tenant or shared-space deployments where documenting who accessed network gear matters for compliance. The SEAL Combo offers mechanical code access without requiring key management. The Swing Handle is the right choice for secure server rooms where the room itself is the access control boundary.
  • Cable Management Options (None / Cable Bar / Clear): The Cable Bar configuration provides horizontal routing points that keep patch cables organized and reduce airflow restriction from cable bundles draped across equipment faces. The Clear option maximizes interior visibility while maintaining some routing structure. Specifying cable management at the cabinet level is cheaper and cleaner than retrofitting it later after the enclosure is fully patched.

Integration & Compatibility

The GL36WMCMP-W-SH-00-00 accepts standard 19-inch rackmount equipment across all three depth configurations. The enclosure is compatible with the full range of wall mount cabinet accessories and is a natural pairing with PoE network switches in edge and branch deployments where a full floor-standing rack is impractical. For environments running structured cabling, the cabinet pairs with patch panels to centralize horizontal runs from workstations and IP cameras. The SEAL Electronic access control option integrates with building access management workflows for facilities that track physical access to network infrastructure. When planning power for equipment installed in this enclosure, refer to the PDU and power distribution category for compatible 1U and 0U options sized to wall mount cabinet depths.

Frequently Asked Questions

Q: What rack unit capacities are available for the GL36WMCMP-W-SH-00-00?

A: The GL36WMCMP-W-SH-00-00 is available in three depth/capacity configurations: 24-inch depth (12U), 36-inch depth (19U), and 48-inch depth (25U). Select based on your actual equipment count plus a reasonable growth buffer.

Q: Does the GL36WMCMP-W-SH-00-00 include active cooling, and when should I specify it?

A: Yes — the cabinet is configurable with fan airflow. Specify the fan option when your installed equipment load (particularly PoE switches or dense patch+compute combinations) generates heat that passive convection cannot adequately dissipate in a closed wall mount enclosure.

Q: What door options are available, and which is best for a shared office environment?

A: Three door types are offered: Plexi (clear, allows visual status checks), Mesh (maximizes passive airflow), and Solid (cleanest appearance, no visibility into the cabinet). For a shared office environment, the Plexi door is typically preferred so IT staff can quickly verify equipment status without unlocking the enclosure.

Q: What access control options does the GL36WMCMP-W-SH-00-00 support?

A: Three options are available: Swing Handle (standard key-free latch), SEAL Combo (mechanical combination lock), and SEAL Electronic (electronic lock with audit trail capability). SEAL Electronic is the right choice for regulated environments or multi-user facilities where access logging to the enclosure is required.

Q: Is cable management included, and what are the options?

A: Cable management is configurable — options are None, Cable Bar (horizontal routing supports), and Clear. For any deployment beyond a small temporary installation, specifying Cable Bar at the time of order is strongly recommended to keep patch cables routed cleanly and maintain airflow through the cabinet interior.

Q: What color is this specific model and why does it matter?

A: The GL36WMCMP-W-SH-00-00 is finished in Winter White. This is relevant for office, healthcare, and retail environments where a black rack enclosure would be visually conspicuous. Vertiv also offers the same enclosure in Black for data center and back-of-house deployments where color is not a consideration.

Jerry Tildsen
Jerry Tildsen

The GL36WMCMP-W-SH-00-00 is one of those enclosures I end up specifying frequently for branch office and campus edge deployments precisely because of the three-depth configuration range — the 19U (36-inch) variant hits the sweet spot for a typical IDF closet running a 24-port PoE switch, a patch panel, and a small UPS without burning wall real estate on unnecessary depth. The Winter White finish and SEAL Electronic access option together make this cabinet a legitimate choice for installations where the enclosure is visible to building occupants and physical access logging matters.

Technical Highlights:

  • 19U / 36-inch Depth: The 19U configuration accommodates a full 1U patch panel, a 1U managed switch, a 2U UPS, and leaves room for structured cable management without the capacity anxiety that comes with a 12U enclosure — the 12U fills up faster than most planners expect once you account for blanking panels and a brush strip.
  • Fan Airflow Configuration: Active fan airflow is the right call any time you are mounting a PoE switch handling more than 8–10 active ports in a sealed or low-ventilation space. Passive convection alone in a wall cabinet is rarely sufficient under real load — the fan option prevents thermal throttling on the switch without requiring you to leave the door open.
  • SEAL Electronic Access Control: For multi-technician environments or facilities with IT compliance requirements, the electronic lock generates an access log that Swing Handle and Combo options simply cannot provide. If your customer needs to demonstrate physical access controls to an auditor, this is the lock tier to specify.

Deployment Considerations:

  • Confirm the wall structure can support the fully loaded weight before mounting — a 19U enclosure with a switch, UPS, and patch panel will exceed 50 lbs; stud or blocking reinforcement is typically required for drywall installations.
  • The Plexi door option, while useful for visual status checks, does not substitute for a locked enclosure in shared spaces — combine it with SEAL Electronic or SEAL Combo access control rather than defaulting to Swing Handle just because the door is transparent.

For a healthcare or professional services office rollout where the IDF is in a hallway or common area, the GL36WMCMP-W-SH-00-00 in Winter White with Plexi door and SEAL Electronic lock is the configuration I would specify without hesitation — it satisfies both the aesthetic and physical access control requirements in a single enclosure rather than requiring a custom solution.

Specifications
Height: 24" (12U)36" (19U)48" (25U)
Color: BlackWinter White
Door: PlexiMeshSolid
Access Control: Swing HandleSEAL ComboSEAL Electronic
Airflow: NoneFan
Cable Management: NoneCable BarClear
freight: 565.40
Q&A
Reviews
Have Questions?

Vertiv WM Premium 19UX24X32 FAN Gray - GL36WMCMP-W-SH-00-00

$2,030.00
$1,379.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources