Image coming soon
Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv GL36WMCMP-W-SC-00-00 Wall Mount Network Enclosure — Multi-Configuration

Overview

The Vertiv GL36WMCMP-W-SC-00-00 is a configurable wall mount enclosure designed for structured wiring closets, edge deployments, and distributed network equipment rooms where floor space is not an option. Available in three height profiles — 24" (12U), 36" (19U), and 48" (25U) — this enclosure gives installers the flexibility to right-size the cabinet to the rack unit load without over-specifying the footprint. Finished in Winter White, the GL36WMCMP-W-SC-00-00 suits office environments and light commercial installations where aesthetics matter alongside function.

This is part of the Vertiv enclosure and power line, a catalog built around the needs of IT infrastructure and physical layer deployments. If you are specifying a wall mount network cabinet for a branch office IDF, a retail POS backroom, or a small server room, the configuration flexibility here covers most scenarios without ordering custom.

Key Features

  • Three Height Options (12U / 19U / 25U): Ordering the GL36WMCMP-W-SC-00-00 in 24", 36", or 48" heights means you're not locked into a single rack unit count. A 12U suits a single switch and patch panel in a small branch. A 25U handles a switch stack plus a UPS plus patch density — keep that in mind when specifying for a multi-floor buildout where each IDF will grow over time.
  • Three Door Options (Plexi / Mesh / Solid): Plexi doors let you do a visual status check without opening the cabinet — useful in a hallway or reception area where staff need to see indicator lights without touching equipment. Mesh improves passive airflow significantly in warmer closets. Solid doors are the right call when the enclosure is in a secured room and you want the cleanest appearance or maximum dust containment.
  • Winter White Color Option: The Winter White finish integrates with drop-ceiling tile environments and office wall colors far better than traditional black. If you're mounting this in a conference room AV closet or an open office communications area, this is the finish to specify — it doesn't draw attention the way a black cabinet does in a white-wall corridor.
  • Three Access Control Tiers (Swing Handle / SEAL Combo / SEAL Electronic): A basic swing handle works fine for locked server rooms where physical access is already controlled. SEAL Combo adds a combination lock — appropriate when the cabinet lives in a semi-public space like a retail back room. SEAL Electronic is the right call when you need audit-trail access logging: who opened it, when — a requirement in PCI and HIPAA-adjacent environments where equipment access must be documented. Pair with your access control infrastructure policies for a complete physical security layer.
  • Airflow Options (None / Fan): Passive (no fan) works when the switch and patch panel load is modest and the closet has ambient air exchange. Fan-equipped configurations actively exhaust heat — necessary when you're running PoE switches at significant wattage loads or the closet is interior with no HVAC supply. Skipping the fan on a fully loaded 25U with a PoE switch is a common field mistake — specify fan if total equipment wattage exceeds roughly 200W in a standard enclosed telecom closet.
  • Cable Management Options (None / Cable Bar / Clear): The Cable Bar option gives structured routing for patch cables inside the enclosure — the difference between a clean installation that a technician can actually maintain and a mass of cables that defeats future troubleshooting. Clear cable management panels keep the front tidy while allowing airflow. Specify cable management at order time — it's significantly harder to retrofit cleanly in a wall mount configuration than in a floor cabinet. Consult a network infrastructure planning guide if you're working out patch density for a new IDF.

Integration & Compatibility

The GL36WMCMP-W-SC-00-00 uses standard 19-inch EIA rack spacing, compatible with patch panels, 1U and 2U switches, fiber enclosures, PDUs, and UPS units designed for 19" mounting. The three height variants cover the most common IDF configurations in SMB and enterprise edge deployments. All access control options (Swing Handle, SEAL Combo, SEAL Electronic) are specified at time of order — confirm your access control requirement before purchase since field upgrades require door hardware changes. Fan and cable management options are likewise order-time configurations. Work with power and cooling accessories if you're adding a UPS or PDU inside the enclosure — wall mount load ratings must be confirmed against the installed wall type and stud spacing before mounting a fully loaded 25U cabinet.

Frequently Asked Questions

Q: What rack unit capacities does the GL36WMCMP-W-SC-00-00 support?

A: The GL36WMCMP-W-SC-00-00 is available in three heights: 24 inches (12U), 36 inches (19U), and 48 inches (25U). The specific height and rack unit count is selected at time of order.

Q: What door styles are available for the GL36WMCMP-W-SC-00-00?

A: Three door options are available: Plexi (clear acrylic for visual status checks without opening), Mesh (improved passive airflow), and Solid (maximum dust containment and cleanest appearance). Door type is specified at order time.

Q: Does the GL36WMCMP-W-SC-00-00 support electronic access control?

A: Yes. The GL36WMCMP-W-SC-00-00 offers three access control configurations: Swing Handle (standard), SEAL Combo (combination lock), and SEAL Electronic (electronic lock with audit-trail capability). The SEAL Electronic option is appropriate for environments requiring documented equipment access logs.

Q: Does the GL36WMCMP-W-SC-00-00 come with a fan?

A: Fan inclusion is an order-time configuration option — the enclosure is available with or without a fan. Specify the fan option when the installed equipment load generates significant heat or the installation location has limited ambient airflow.

Q: What cable management options are available for the GL36WMCMP-W-SC-00-00?

A: Three cable management configurations are available: None, Cable Bar (structured routing for patch cables), and Clear (clear management panels). Cable management should be specified at order time, as retrofitting in a wall mount enclosure is significantly more difficult than in a floor cabinet.

Q: Is the GL36WMCMP-W-SC-00-00 available in colors other than Winter White?

A: The GL36WMCMP-W-SC-00-00 is available in Winter White and Black. Color is selected at time of order. Winter White is suited to office and light commercial installations; Black suits traditional data center and equipment room environments.

Eden Phillips
Eden Phillips

The GL36WMCMP-W-SC-00-00 is one of those enclosures that looks simple on paper but gets complex fast at the point of specification — there are effectively three height choices, three door choices, two color choices, three access control tiers, two airflow configs, and three cable management options, all intersecting at order time. Getting that matrix right before you submit the PO is the whole game here, because wall mount cabinets are not easy to swap out post-installation.

Technical Highlights:

  • SEAL Electronic Access Control: The electronic lock tier is the differentiator for regulated environments — PCI DSS scope, HIPAA-adjacent IT closets, or any facility where a physical access log for network equipment is required by policy. Swing Handle is adequate only when the room itself provides the access control layer.
  • Fan Configuration: Actively managed airflow matters when a PoE switch is running near capacity inside an enclosed wall mount. Passive (no fan) configurations work in open or ventilated spaces; specify fan when the closet is interior, fully enclosed, and the switch load is non-trivial.
  • 12U / 19U / 25U Height Range: The 25U (48") variant is at the practical upper limit for true wall mount — confirm stud spacing and wall load rating before installing a fully populated 25U with a UPS inside. A 12U on a standard interior wall is straightforward; 25U with dense gear is an installation engineering question, not just a product question.

Deployment Considerations:

  • All configuration options (height, door, color, access control, airflow, cable management) are specified at order time — confirm with the end user before purchasing, particularly the access control tier, since field changes to door hardware require additional parts and labor.
  • The Winter White finish is specifically suited to open-office IDF closets and AV equipment installations where a black cabinet reads as out-of-place. If the cabinet is in a traditional locked server room, Black is the standard spec.

This enclosure is the right call for a multi-site enterprise rollout where each branch IDF needs a configurable, standardized wall mount solution — the ability to order the same base SKU in different heights and door configurations per site, while standardizing on SEAL Electronic access control across all locations, is exactly the use case this product family is built for.

Specifications
Height: 24" (12U)36" (19U)48" (25U)
Color: BlackWinter White
Door: PlexiMeshSolid
Access Control: Swing HandleSEAL ComboSEAL Electronic
Airflow: NoneFan
Cable Management: NoneCable BarClear
freight: 565.40
Q&A
Reviews
Have Questions?

Vertiv WM Premium 19UX24X32 Gray - GL36WMCMP-W-SC-00-00

$2,219.00
$1,508.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources