Vertiv VRELN100-103C13TL6 BASIC - 38139
10-outlet, basic rack power distribution unit (PDU) designed to provide reliable power to IT equipment within a standard server rack
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv VRELCN100-103C13TL6 (part number 38128) is a metered, standard-class rack power distribution unit built for data center operators who need real-time power visibility at the unit level without the overhead of networked or switched PDU infrastructure. Rated at 30A/208V with a 4.9kW load capacity and feeding ten IEC C13 receptacles, this is a workhorse unit for 1U-dense server rows where overload prevention during deployments matters and remote management doesn't.
Part of the Vertiv PowerIT rPDU line, the 38128 targets IT teams commissioning rack environments where every dollar not spent on network cards or remote access licenses is a dollar kept in the deployment budget. If your operators are physically present at the rack — commissioning, rebalancing load, or swapping gear — local metering at ±2% accuracy is often all you need.
The ten IEC C13 outlets feed standard C14 inlets on 1U/2U server PSUs, KVM switches, patch panel power injectors, and most rack-mount networking gear. Vertiv's rack PDU lineup spans metered, switched, and outlet-level metered tiers — the 38128 sits at the metered standard tier, appropriate when aggregate unit-level monitoring satisfies operational requirements and per-outlet switching or metering isn't needed.
This unit does not provide network connectivity, SNMP, or remote access — if your operations center needs to pull power data remotely or cut power to individual outlets, step up to a networked or switched PDU variant. For data center power infrastructure planning that includes branch circuit monitoring, Vertiv's Geist-branded and Avocent-integrated tiers provide that capability within the same product family ecosystem.
The L6-30P input requires a 30A 208V circuit with a twistlock receptacle — confirm your PDU whip or in-row power panel is provisioned accordingly before ordering. Most colocation facilities provide L6-30P feeds as standard for 208V cabinet power, but verify the circuit amperage matches: a 20A breaker feeding an L6-30 receptacle won't support full load on this unit. Pairing with a compatible UPS system upstream ensures protected power delivery to all ten outlets.
RoHS compliance and UL/c-UL listing (Accessory 1950) satisfy standard data center facility requirements for rack power equipment in North American and Canadian deployments. The 10–45°C operating range covers typical data center environments (ASHRAE A1/A2 classes) but is not rated for edge or outdoor enclosures running above 45°C.
Q: What plug and circuit type does the Vertiv 38128 require?
A: The 38128 uses a NEMA L6-30P twistlock plug and requires a 30A, 208V circuit. It is not compatible with standard 120V NEMA 5-15 or 5-20 outlets. Confirm your rack or cabinet is provisioned with a 208V L6-30 receptacle before installation.
Q: How many outlets does the 38128 provide and what type are they?
A: The 38128 provides ten IEC C13 receptacles, arranged in two banks of five. Each bank is protected by two 15A thermal breakers, with a maximum output of 15A per receptacle bank. IEC C13 feeds standard C14 inlets on most 1U/2U servers and rack-mount appliances.
Q: Can the 38128 be mounted both horizontally and vertically?
A: Yes. The 17-inch chassis supports horizontal 1U rackmount installation using included 19-inch panel mount brackets, as well as vertical (0U) deployment along a rack rail using the included SLB-4 brackets. Vertical mounting frees up rack unit space in dense deployments.
Q: What power metrics does the local display show?
A: The onboard LED display provides a scrolling readout of Amps, Volts, Watts, and Power Factor (A, V, W, PF) at the aggregate unit level. Accuracy is ±2% with a full-scale 60Hz sine wave input. This is local-only — the 38128 has no network interface or remote monitoring capability.
Q: Is the Vertiv 38128 TAA compliant for government procurement?
A: Yes. The 38128 is manufactured in the USA and is both TAA Compliant and Buy American Act COTS Compliant, making it eligible for federal and government data center procurement programs.
Q: What is the warranty on the 38128?
A: Vertiv provides a 5-year limited warranty on the 38128.

The 38128 is one of those rack PDUs that earns its place by doing exactly what the spec sheet says and nothing more — which is precisely what you want in a metered standard unit. The four independent 15A thermal breakers are the spec I'd call out first for anyone commissioning a high-density row: instead of one breaker that takes down all ten outlets when a misbehaving server PSU draws too hard, you lose a bank of five at most. That's the difference between a brief interruption on half the rack and a full-rack outage.
Technical Highlights:
Deployment Considerations:
The 38128 is the right call for colocation customers provisioning standard 208V 30A cabinets who need load visibility during server commissioning and rebalancing without paying for network management infrastructure they won't use — government data center builds with BAA compliance requirements are a particularly clean fit.