Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv 38563 Metered Standard rPDU 30A 208V 8-Outlet

Overview

The Vertiv VRELCN080-103C13TL6 — sold under part number 38563 — is a metered standard rackmount PDU designed for IT rack deployments where load visibility matters during provisioning and maintenance. Rated at 30A/208V/4.9kW with eight IEC C13 outlets, it fits dense 1U rackmount environments in data centers, network closets, and edge deployments where administrators need real-time power data without managing a networked PDU infrastructure. The local digital RMS scrolling display shows amperage, voltage, watts, and power factor at a glance — no software, no SNMP, no network port required. Browse the full Vertiv power distribution catalog for the complete rPDU lineup.

Key Features

  • 30A/208V Input, 4.9kW Load Capacity: Sized for high-density server or storage rows running dual-corded equipment. At 4.9kW continuous, this unit can carry a loaded 2U server with headroom — without dipping into trip territory on a shared circuit. Pair with a rackmount PDU strategy that matches your UPS output breaker ratings.
  • Eight IEC C13 Outlets in Banks of Four: Eight outlets split into two banks of four, each bank protected by its own 15A thermal breaker. This means a single load fault trips only half the unit, keeping the other four outlets live — a meaningful protection boundary when distributing power across mixed equipment in a rack.
  • Local RMS Scrolling Power Meter ±2% Accuracy: The onboard LED display scrolls through real-time amps, volts, watts, and power factor with ±2% accuracy at full-scale 60Hz sine wave input. When you are commissioning a rack or moving equipment, you get instant load feedback without pulling up a management interface or connecting a laptop.
  • Four 15A Thermal Breakers for Overcurrent Protection: Thermal breakers — not fuses — mean a tripped circuit resets without replacing a component. With four independent breakers each covering two outlets, a device fault or inrush surge is isolated to a small subset of the load.
  • NEMA L6-30P Twistlock Input Plug, 10ft Cord: The L6-30P plug connects to standard 30A/208V PDU branch circuits or UPS output receptacles. The 10ft 10/3 AWG cord gives enough reach from the top of a standard 42U cabinet to a floor-level UPS or power strip without extensions.
  • Flexible 17in Horizontal/Vertical Mounting: The 17-inch chassis mounts horizontally (occupying 1U) or vertically along a cabinet rail using included 19in panel mount brackets and SLB-4 brackets. Vertical mounting frees up U-space for additional equipment — relevant in fully loaded cabinets.
  • Heavy Steel Powder Coat Construction, Black Finish: The steel chassis with black powder coat finish is built for long-term rack life. At 6 lbs shipped weight, installation is manageable solo. Dimensions are 17.00in × 1.72in × 1.61in — thin enough for tight 1U horizontal slots.
  • TAA Compliant, Buy American Act COTS Compliant, USA Origin: Manufactured in the USA and certified TAA and Buy American Act COTS compliant. This matters for federal, defense, and government-funded IT deployments where domestic sourcing requirements apply. RoHS and UL/c-UL Listed (Accessory 1950) round out the compliance profile.
  • 50/60Hz Operation, 200–240V Input Range: Operates across 200–240V input at 50 or 60Hz — useful in mixed-frequency environments or international deployments where 50Hz grids are the norm.
  • 5-Year Limited Warranty: Vertiv backs the 38563 with a five-year limited warranty — longer than the typical two- or three-year coverage on comparable units, which extends the useful lifecycle calculation for capital planning purposes.

Integration and Compatibility

The 38563 is compatible with any rack or cabinet accepting 17-inch PDUs, including standard 19-inch EIA enclosures. The L6-30P input connects directly to UPS units and PDU panels with matching 30A/208V output receptacles — common in APC, Eaton, and Vertiv UPS product lines. For deployments requiring rack power management beyond local metering, Vertiv's networked rPDU families share form factor and mounting options, allowing side-by-side deployment or upgrade without cabinet reconfiguration. No software installation, drivers, or IP addressing are required for the local metering function — the display is self-contained and active as soon as the unit is energized. See also UPS systems for upstream power protection sizing guidance. For environments needing remote outlet switching or per-outlet metering, consider stepping up within the Vertiv rPDU line to a switched or outlet-metered variant.

Frequently Asked Questions

Q: What is the input plug type and cord length on the Vertiv 38563?

A: The 38563 uses a NEMA L6-30P twistlock input plug on a 10ft, 10/3 AWG power cord. It connects to 30A/208V circuits — common on UPS output panels and dedicated PDU branch circuits.

Q: How many outlets does the 38563 provide and what type are they?

A: The unit provides eight IEC C13 receptacles, arranged in two banks of four. Each bank is protected by a dedicated 15A thermal breaker, so a fault on one bank does not affect the other four outlets.

Q: Is the Vertiv 38563 TAA compliant for government procurement?

A: Yes. The 38563 is TAA Compliant, Buy American Act COTS Compliant, and manufactured in the USA — qualifying it for federal and government-funded IT procurement programs with domestic sourcing requirements.

Q: What does the local display on the 38563 show?

A: The onboard LED RMS scrolling power meter displays real-time amperage (A), voltage (V), watts (W), and power factor (PF) at the aggregate unit level, with ±2% accuracy on a full-scale 60Hz sine wave input. No network connection or software is needed.

Q: Can the 38563 mount both horizontally and vertically in a rack?

A: Yes. The 17-inch chassis supports horizontal (1U) and vertical rackmount configurations. The unit ships with 19in panel mount brackets and SLB-4 brackets to support both orientations in standard EIA 19-inch cabinets.

Q: What is the warranty on the Vertiv 38563?

A: Vertiv provides a 5-year limited warranty on the 38563 — verified from the manufacturer's product documentation.

Karl Wilson
Karl Wilson

The 38563 occupies a specific and useful niche: a 30A/208V metered PDU with a real local display, thermal breakers you can reset without tools, and a five-year warranty — at a form factor that fits 1U horizontal or runs vertical to preserve U-space. For teams that don't need SNMP or remote switching but do need instant load visibility during rack builds and equipment moves, this unit eliminates the guesswork without the overhead of a managed PDU.

Technical Highlights:

  • ±2% RMS metering accuracy: The scrolling LED display reads A, V, W, and PF with ±2% accuracy at full-scale 60Hz — accurate enough to verify load balance before cutting over to production, not just a rough indicator.
  • Thermal breaker overcurrent protection: Four 15A thermal breakers in two-outlet pairs reset manually without fuse replacement. A hard fault on one outlet pair doesn't strand the rest of the bank — and certainly not the other bank.
  • TAA/BAA COTS compliance: USA-manufactured with TAA and Buy American Act COTS certifications. This is often a hard procurement gate on federal contracts and SLED deployments — not a nice-to-have.

Deployment Considerations:

  • The L6-30P input requires a 30A/208V circuit or UPS output — verify your upstream UPS or PDU panel has a matching receptacle before ordering. Most Vertiv and APC 208V UPS units in the 5–10kVA range ship with L6-30 outputs, but confirm your specific model.
  • With 15A per receptacle bank and eight C13 outlets total, this unit is not sized for high-draw C19-class devices (large PSUs, high-density GPU servers). If your load mix includes C19 equipment, look at a C19-capable variant within the Vertiv rPDU family.

The 38563 is a practical fit for edge data rooms, branch office server closets, and co-location cage builds where local power visibility is required but a managed PDU adds unnecessary complexity and cost. It's also a reliable choice on government and municipal IT deployments where TAA compliance is non-negotiable.

Specifications
Model Number: VRELCN080-103C13TL6
Category: Metered
Sub Category: Standard
Power Configuration: 30A, 208V, 4.9kW
Physical Configuration: 17in / 432mm, Horizontal/Vertical
Monitoring: Local (A, V, W, PF)
Accuracy: +/- 2%
Plug Form: L6-30P
Receptacle Quantity: 8
Receptacle Type: IEC C13
Voltage: 200-240V
Current: 30A
Load Capacity: 4.9kW
Frequency: 50/60Hz
Over Current Protection: 4x 15A Thermal Breakers
Power Cable Length: 10ft
Plug Type: NEMA L6-30P Twistlock
Receptacle Output: 15A per bank
Operating Temperature Range: 10-45C / 50-113F
Chassis Dimensions: 17.00in x 1.72in x 1.61in
Shipped Weight: 6lbs (2.72kg)
Warranty: 5-year limited
Compliance: RoHS, UL & c-UL Listed
Country of Origin: USA, TAA Compliant, Buy American Act COTS Compliant
Q&A
Reviews

Vertiv VRELCN080-103C13TL6 BASIC - 38563

$621.00
$425.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources