Vertiv VRELN100-103C13TL6 BASIC - 38139
10-outlet, basic rack power distribution unit (PDU) designed to provide reliable power to IT equipment within a standard server rack
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv VRELCN080-103C13TL6 — sold under part number 38563 — is a metered standard rackmount PDU designed for IT rack deployments where load visibility matters during provisioning and maintenance. Rated at 30A/208V/4.9kW with eight IEC C13 outlets, it fits dense 1U rackmount environments in data centers, network closets, and edge deployments where administrators need real-time power data without managing a networked PDU infrastructure. The local digital RMS scrolling display shows amperage, voltage, watts, and power factor at a glance — no software, no SNMP, no network port required. Browse the full Vertiv power distribution catalog for the complete rPDU lineup.
The 38563 is compatible with any rack or cabinet accepting 17-inch PDUs, including standard 19-inch EIA enclosures. The L6-30P input connects directly to UPS units and PDU panels with matching 30A/208V output receptacles — common in APC, Eaton, and Vertiv UPS product lines. For deployments requiring rack power management beyond local metering, Vertiv's networked rPDU families share form factor and mounting options, allowing side-by-side deployment or upgrade without cabinet reconfiguration. No software installation, drivers, or IP addressing are required for the local metering function — the display is self-contained and active as soon as the unit is energized. See also UPS systems for upstream power protection sizing guidance. For environments needing remote outlet switching or per-outlet metering, consider stepping up within the Vertiv rPDU line to a switched or outlet-metered variant.
Q: What is the input plug type and cord length on the Vertiv 38563?
A: The 38563 uses a NEMA L6-30P twistlock input plug on a 10ft, 10/3 AWG power cord. It connects to 30A/208V circuits — common on UPS output panels and dedicated PDU branch circuits.
Q: How many outlets does the 38563 provide and what type are they?
A: The unit provides eight IEC C13 receptacles, arranged in two banks of four. Each bank is protected by a dedicated 15A thermal breaker, so a fault on one bank does not affect the other four outlets.
Q: Is the Vertiv 38563 TAA compliant for government procurement?
A: Yes. The 38563 is TAA Compliant, Buy American Act COTS Compliant, and manufactured in the USA — qualifying it for federal and government-funded IT procurement programs with domestic sourcing requirements.
Q: What does the local display on the 38563 show?
A: The onboard LED RMS scrolling power meter displays real-time amperage (A), voltage (V), watts (W), and power factor (PF) at the aggregate unit level, with ±2% accuracy on a full-scale 60Hz sine wave input. No network connection or software is needed.
Q: Can the 38563 mount both horizontally and vertically in a rack?
A: Yes. The 17-inch chassis supports horizontal (1U) and vertical rackmount configurations. The unit ships with 19in panel mount brackets and SLB-4 brackets to support both orientations in standard EIA 19-inch cabinets.
Q: What is the warranty on the Vertiv 38563?
A: Vertiv provides a 5-year limited warranty on the 38563 — verified from the manufacturer's product documentation.

The 38563 occupies a specific and useful niche: a 30A/208V metered PDU with a real local display, thermal breakers you can reset without tools, and a five-year warranty — at a form factor that fits 1U horizontal or runs vertical to preserve U-space. For teams that don't need SNMP or remote switching but do need instant load visibility during rack builds and equipment moves, this unit eliminates the guesswork without the overhead of a managed PDU.
Technical Highlights:
Deployment Considerations:
The 38563 is a practical fit for edge data rooms, branch office server closets, and co-location cage builds where local power visibility is required but a managed PDU adds unnecessary complexity and cost. It's also a reliable choice on government and municipal IT deployments where TAA compliance is non-negotiable.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Vertiv products? Shop the full Vertiv catalog →
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price