Vertiv VHVLAN102-102C13TL6 BASIC - 13192
Rack-mountable power distribution unit (PDU) designed to provide reliable power to IT equipment within a data center or network closet
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv VHVLCN102-102C13TL6 — SKU 38171 — is a metered rack power distribution unit built for high-density IT environments where you need instant visibility into power consumption without deploying network-managed infrastructure. It delivers 20A at 208V (3.3kW continuous load) across 10 IEC C13 outlets arranged in two banks of five, with a local LED scrolling display that shows amps, volts, watts, and power factor in real time. If you've ever triggered a circuit breaker mid-deployment because you didn't know the actual draw on the PDU, this is the unit that solves that problem without requiring SNMP or a management card.
Manufactured in the USA and Vertiv factory-tested at 100% before shipment, the 38171 is TAA Compliant and Buy American Act COTS Compliant — relevant for federal, DoD, and government-contract data center builds where procurement rules are enforced at the hardware level. RoHS and UL/c-UL Listed 60950 certifications are included.
The 10 IEC C13 receptacles are the standard 15A-rated connector found on virtually every 1U–4U server, NAS, KVM switch, and network device PSU on the market. The L6-20P input connects to 208V branch circuits fed by standard data center UPS output panels from Vertiv, Eaton, APC, and others running NEMA L6-20R receptacles. Since this unit carries no network management interface, it integrates passively into any rack infrastructure deployment regardless of VMS, BMS, or DCIM platform — there are no drivers, no IP addressing, and no firmware to manage. For environments that need remote monitoring or outlet-level switching, consider stepping up to Vertiv's networked or switched rPDU families within the same product line.
The TAA and Buy American Act COTS compliance flags are meaningful for integrators bidding on federal contracts through GSA schedule or similar procurement vehicles — confirm your specific contract vehicle requirements before ordering, but the hardware itself meets the country-of-origin requirement with USA manufacturing. Consult a rack power planning guide to size branch circuits and verify UPS output capacity before deploying multiple units in the same cabinet.
Q: Is the Vertiv 38171 TAA compliant?
A: Yes. The 38171 is TAA Compliant and Buy American Act COTS Compliant, with country of origin listed as USA. It is appropriate for federal and government-contract data center procurements that require these designations.
Q: What is the warranty on the VHVLCN102-102C13TL6?
A: Vertiv provides a 5-year limited warranty on the 38171.
Q: Can the 38171 be mounted both horizontally and vertically?
A: Yes. The unit ships with 19-inch panel mount brackets for 1U horizontal rackmount installation and SLB-4 brackets for zero-U vertical side-mount on a standard 19-inch cabinet rail.
Q: Does the 38171 have per-outlet switching or per-outlet metering?
A: No. The 38171 is a metered Standard unit — monitoring is aggregate at the total unit level (amps, volts, watts, power factor). There is no per-outlet metering, switching, or remote management capability. For per-outlet control, you would need to look at Vertiv's switched or managed rPDU models.
Q: What input plug does the 38171 use, and how long is the power cord?
A: The unit uses a NEMA L6-20P twistlock input plug on a 10ft, 12/3 AWG power cord. This connects to standard 208V L6-20R receptacles common on data center UPS output panels and PDPs.
Q: What is the maximum load per outlet bank on the 38171?
A: The 10 IEC C13 outlets are arranged in two banks of five. Each bank is rated at a maximum of 15A. The total unit capacity is 20A / 3.3kW at 208V — plan your per-bank loads accordingly to avoid exceeding the bank limit even if the unit-level draw remains under 20A.

The 38171 is a unit I recommend specifically when the site has 208V branch circuits but the team doesn't want to manage a networked PDU — the local LED display showing amps, volts, watts, and power factor at ±2% accuracy gives technicians the load data they actually need during commissioning and moves without adding IP management overhead to a passive infrastructure component. The VHVLCN102-102C13TL6 occupies a well-defined slot in the Vertiv rPDU lineup: metered, not managed.
Technical Highlights:
Deployment Considerations:
This unit is best positioned in colo-style deployments and government data centers running 208V three-phase distribution where TAA compliance is required, cabinet density is moderate (10 devices per PDU), and the team needs basic load visibility without the cost or management burden of a network-connected PDU.