Vertiv PBRPSI5-1500VA 2YR Basic
1500VA/900W Uninterruptible Power Supply (UPS) designed to provide essential battery backup for sensitive electronic equipment
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv 2XPRC200-103D20TL6 (part number 12333) is a metered, standard-class horizontal rackmount power distribution unit designed for data center racks and dense IT cabinets running on 208V power infrastructure. It delivers 30A of continuous input current across 20 NEMA 6-20R outlets in a 2U, 19-inch horizontal chassis — the kind of specification that fits squarely in mid-density server rows where load visibility matters and outlet count is non-negotiable.
Vertiv's Vertiv PowerIT rPDU line positions this unit as a field-reliable, locally monitored PDU for environments where remote network management isn't required but real-time load awareness is. TAA compliance and Buy American Act COTS qualification make it a straightforward procurement choice for federal and government-adjacent facilities.
The 12333 operates as a standalone rackmount PDU with no network interface or management card slot — monitoring is local-only via the LED display. This keeps the unit simple and eliminates the attack surface of network-connected PDUs in security-sensitive environments. If your deployment requires remote outlet switching, per-outlet metering, or SNMP/Modbus integration, look at Vertiv's switched or networked rPDU variants instead.
The NEMA 6-20R receptacles accept standard NEMA 6-20P plugs, which are the default output connector on most server and storage PSUs configured for 200–240V input. The L6-30P input plug connects directly to 30A 208V circuit breaker panels or in-row power strips without a whip adapter. Confirm your facility's panel feed is 208V (not 240V single-phase) before specifying — the 4.9kW load capacity assumes 208V.
For racks requiring dual-feed redundancy, pair two units — one per PDU feed — to deliver A+B power paths to dual-PSU servers. Each unit fits in standard 19-inch server racks and cabinets; the recess-mount option helps in shallow cabinets where depth is constrained.
Q: Is the Vertiv 12333 TAA compliant for government procurement?
A: Yes. The 12333 is manufactured in the USA and carries both TAA (Trade Agreements Act) compliance and Buy American Act COTS compliance, making it eligible for GSA schedules and federal/state contracts requiring domestic-origin hardware.
Q: What is the maximum continuous load I should plan for on the 12333?
A: The unit is rated at 30A input / 4.9kW at 208V. Per NEC 80% continuous-load rule, plan for a maximum continuous draw of 24A (approximately 5kW theoretical, ~4.0kW practical per breaker group). Each of the two 20A breakers handles 10 outlets; size each group to stay under 16A continuous.
Q: What does the local display on the 12333 actually show?
A: The scrolling LED display reads total unit power data in real time: amperage (A), voltage (V), wattage (W), and power factor (PF) with ±2% RMS accuracy. It monitors the aggregate input — not per-outlet — so it reflects the total load across all 20 receptacles.
Q: What is the warranty on the 12333?
A: Vertiv provides a 5-year limited warranty on the 2XPRC200-103D20TL6 (part number 12333).
Q: Can the 12333 be used in a 230V international facility?
A: The input voltage range is 200–240V at 50/60Hz, so it can accept 230V power feeds used in international data centers. Confirm local plug and circuit breaker compatibility — the factory cord ships with a NEMA L6-30P twistlock for North American 30A circuits.
Q: Does the 12333 support remote monitoring or SNMP management?
A: No. The 12333 is a local-metered-only unit with no network interface or management card slot. All power monitoring is done via the front-panel LED display. For remote SNMP or Modbus monitoring, Vertiv's networked rPDU models are the appropriate path.

The Vertiv 12333 (2XPRC200-103D20TL6) sits in a specific but common deployment niche: 208V rack environments where the team needs real-time load visibility at the PDU without the overhead — or attack surface — of a networked management card. The dual 20A double-pole magnetic breakers splitting 10 outlets each is the detail I'd point integrators toward first; that topology means a breaker trip from a misbehaving device takes down half the rack at most, not the whole thing, which is exactly the behavior you want in a shared-tenancy colocation cage or a mixed-workload server row.
Technical Highlights:
Deployment Considerations:
For a government-facing colocation provider or federal agency data center running 208V power infrastructure and needing TAA-clean hardware with reliable load metering and zero network attack surface, the 12333 is a well-matched, straightforward choice. It's not the right fit for MSPs who need remote outlet control or per-outlet billing data, but for environments where simplicity and compliance are the primary requirements, it delivers both without unnecessary complexity.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Vertiv products? Shop the full Vertiv catalog →
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price