Vertiv 2VHVLAN162-102C13TL6 BASIC - 12340
Rack-mountable power distribution unit (PDU) designed to provide reliable power to network and server equipment
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv VHVLAN102-102C13TL6 (part number 13192) is a metered, rack-mounted power distribution unit built for 208V single-phase environments where you need real-time current visibility without deploying a full switched or networked PDU. It delivers 20A at 208V (3.3kW load capacity) across ten IEC C13 receptacles arranged in two banks of five, with a local LED display showing aggregate RMS current at ±2% accuracy. That's the core value proposition: you get an honest, hardware-level load readout at the unit, so a technician doesn't need remote access or a KVM session to know whether a rack is approaching its breaker limit during a hot-swap or a server migration.
Sourced factory-new and TAA compliant, the 13192 is manufactured in the USA and qualifies under the Buy American Act COTS exception — relevant for federal deployments and government-contract data centers where domestic-origin documentation is non-negotiable.
The 13192 is a local-metered unit — it does not have an Ethernet port, SNMP agent, or remote monitoring capability. It integrates with your power chain via the upstream NEMA L6-20P branch circuit, and all monitoring is read locally at the LED display. If your power distribution architecture requires per-outlet switching, per-outlet current sensing, or integration with a data center infrastructure management (DCIM) platform, you'll need a switched or networked rPDU from the Vertiv PowerIT rPDU line. This unit is purpose-built for environments where aggregate current awareness is sufficient and budget or simplicity argues against a fully managed PDU.
Compatible load devices must use IEC C13 power inlets — the standard connector on 1U rackmount servers, managed switches, and KVM switches. Equipment requiring IEC C19 (high-current 16A) or NEMA 5-15/5-20 (120V) outlets is not compatible with this PDU. Plan your rack PDU outlet mix before deployment if you have mixed-inlet equipment in the same rack.
Q: Is the Vertiv 13192 TAA compliant for government procurement?
A: Yes. The 13192 is manufactured in the USA and is documented as TAA Compliant and Buy American Act COTS Compliant per Vertiv's published specifications.
Q: Does the 13192 support remote monitoring or SNMP?
A: No. The VHVLAN102-102C13TL6 is a local-metered unit only. It provides aggregate RMS current data on the local LED display at ±2% accuracy. There is no Ethernet port, SNMP agent, or remote monitoring capability on this model. For remote visibility, you would need a networked rPDU from the Vertiv line.
Q: What is the maximum load per outlet bank on the 13192?
A: The ten C13 outlets are arranged in two banks of five. Each bank is rated to a maximum of 15A at 208V. The total unit capacity is 20A / 3.3kW, so both banks combined cannot exceed the unit's upstream circuit rating.
Q: Can the 13192 mount both horizontally in a rack unit and vertically in a zero-U position?
A: Yes. The unit ships with 19-inch panel-mount brackets for horizontal 1U rackmount installation and SLB-4 brackets for vertical zero-U side mounting, giving you flexibility in how you use rack space.
Q: What is the warranty on the 13192?
A: Vertiv covers the 13192 with a 5-year limited warranty per their published product documentation.
Q: What plug type does the 13192 use, and how long is the power cord?
A: The 13192 ships with a NEMA L6-20P twistlock plug on a 10-foot, 12/3 AWG power cord. The L6-20P mates with standard 208V twist-lock branch circuit receptacles common in raised-floor data centers.

The 13192 sits in a specific spot in the PDU selection matrix that often gets overlooked: you need current monitoring at the unit level, but you don't need (or can't justify) the cost and complexity of a full SNMP-capable networked PDU. The VHVLAN102-102C13TL6's local digital RMS meter at ±2% accuracy does exactly what a rack technician needs during commissioning and hot-add events — it tells you whether you have headroom before you add the next device, without requiring a laptop, a credentials lookup, or a DCIM platform login.
Technical Highlights:
Deployment Considerations:
The 13192 is the right call for a mid-density 208V colocation rack or enterprise data center row where the ops team wants current confirmation at the unit without adding SNMP management overhead to every PDU in the building — a common and sensible architecture for standardized rack builds of 20–50 cabinets.