Vertiv TOP Panel Perf 29 in W E CAB Knockouts - TPE-29P
29-inch wide top panel designed to provide supplemental cooling for server cabinets
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv TPE-29S is a 29kW (98.9 kBtuh) precision cooling unit designed for equipment rooms, data centers, and dense server environments where standard HVAC cannot maintain the tight temperature and humidity tolerances that compute infrastructure demands. With a 29-inch-wide cabinet profile and knockout provisions for flexible field installation, the TPE-29S fits into constrained mechanical footprints without requiring a full room redesign. If you're specifying Vertiv precision cooling for a mid-density compute environment, this unit addresses the capacity range where most enterprise server rooms operate. (Also searched as TPE 29S.)
The unit ships rated at 98.9 kBtuh (29kW) total nominal sensible cooling capacity, with a net sensible capacity of 91.4 kBtuh (26.8kW) — meaning the overwhelming majority of its output goes directly toward removing heat from equipment, not managing latent (moisture) loads. For a typical server room where the heat load is almost entirely sensible, that ratio matters: you're not wasting capacity on humidity correction when you need degrees of temperature reduction.
The Liebert iCOM control system on the TPE-29S is designed to integrate with Vertiv's monitoring and management ecosystem. In environments that already operate Vertiv power and cooling infrastructure, iCOM enables unified visibility across cooling units from a single interface. For facilities teams managing multiple units, this centralized control capability reduces the overhead of site-level monitoring and supports alarm escalation workflows without adding third-party middleware.
The unit's dual airflow direction support (upflow/downflow) makes it compatible with both raised-floor and non-raised-floor data center designs. Consult your mechanical engineer on refrigerant line routing requirements — the knockout provisions provide flexibility, but the specific R-410A circuit design and line sizing should be validated against the installed capacity and ambient conditions for your site. For sites planning broader infrastructure buildouts, confirm that the iCOM version installed supports your intended BMS or DCIM integration path before commissioning.
Q: What is the total cooling capacity of the Vertiv TPE-29S?
A: The TPE-29S is rated at 98.9 kBtuh (29kW) total nominal cooling capacity, with a net sensible capacity of 91.4 kBtuh (26.8kW).
Q: Does the TPE-29S support both upflow and downflow airflow configurations?
A: Yes. The TPE-29S supports both upflow and downflow airflow directions, making it compatible with raised-floor (downflow into plenum) and non-raised-floor (upflow) installation environments.
Q: What refrigerant does the TPE-29S use?
A: The TPE-29S uses R-410A refrigerant, a widely available refrigerant with established service infrastructure across most commercial HVAC and precision cooling service organizations.
Q: What fan technology does the TPE-29S use for capacity modulation?
A: The unit uses variable-speed electronically commutated (EC) fans, which adjust airflow output to match actual load. EC fans consume significantly less energy than fixed-speed alternatives during partial-load operation, which describes most data center environments most of the time.
Q: What control system does the TPE-29S use?
A: The TPE-29S uses the Liebert iCOM unit control system, Vertiv's integrated controller for monitoring, alarms, and setpoint management. iCOM supports integration with Vertiv's broader monitoring ecosystem and is compatible with centralized facilities management workflows.
Q: What is the nominal airflow rating of the TPE-29S?
A: The TPE-29S is rated at 4,300 CFM nominal airflow, providing the thermal headroom needed to manage rack load spikes in environments without full hot-aisle/cold-aisle containment.

The TPE-29S sits in the 29kW range where a lot of enterprise server rooms land — big enough to handle a real compute load, compact enough at 29 inches wide to fit in mechanical rooms that weren't originally designed around precision cooling. The variable-speed EC fan system is the spec I'd lead with in any capacity conversation: in environments where IT load fluctuates across the day, fixed-speed fan operation wastes energy constantly. EC variable-speed control means the fans are only working as hard as the load demands, which in practice translates to meaningfully lower operating costs over a multi-year run.
Technical Highlights:
Deployment Considerations:
The TPE-29S is the right fit for an enterprise equipment room or mid-density server environment in the 20–30kW IT load range where you need precision temperature control, a manageable footprint, and a control system that integrates into a broader Vertiv monitoring stack rather than running as a standalone appliance.