Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv TPE-24S Top Panel for E-Series Cabinet Enclosures

Overview

The Vertiv TPE-24S is a solid top panel with knockout provisions designed for Vertiv 24-inch-wide E-series enclosures. It supports up to 19.5 Kbtuh (5.70 kW) of net sensible thermal capacity — meaning it's sized for real compute loads, not just passive routing gear. With a nominal airflow rating of 885 CFM and a total capacity of 21.8 Kbtuh (6.40 kW), this panel is engineered to support thermally dense cabinet configurations where airflow continuity at the top of the enclosure is a design requirement. If you're configuring Vertiv enclosure solutions for a compute or network aggregation row, the TPE-24S keeps the thermal envelope intact at the cabinet top without compromising airflow path integrity.

Key Features

  • 19.5 Kbtuh (5.70 kW) Net Sensible Capacity: This rating reflects real sensible heat removal — relevant when you're specifying a cabinet that will carry servers or active networking gear running near thermal limits. Undersized top panels can become bottlenecks in dense rows.
  • 885 CFM Nominal Airflow: High airflow throughput means the panel won't be the restriction in a well-designed hot-aisle/cold-aisle layout. Matching this to your row's CFM budget is straightforward.
  • 21.8 Kbtuh (6.40 kW) Total Capacity: The total capacity figure — slightly above the sensible rating — accounts for latent load, giving you headroom in environments where humidity management also matters alongside cooling.
  • iCOM CMS Monitoring & Management Integration: The TPE-24S integrates with Vertiv's iCOM Control and Monitoring System, so thermal conditions at the cabinet level are visible in the same management interface as your broader cooling infrastructure. This avoids the blind spots that come from unmonitored passive panels in managed deployments.
  • 24-Inch Cabinet Width (610mm): Designed specifically for the 24-inch (610mm) E-series cabinet form factor — confirm your cabinet width before ordering, as Vertiv panels are not interchangeable across width variants.
  • Knockout Provisions: Pre-scored knockouts allow cable or conduit ingress without field-fabricating penetrations, keeping the cabinet's thermal and physical integrity intact while maintaining installation flexibility for top-entry cable runs in structured cabling environments.
  • Air-Cooled Heat Rejection: Heat rejection is air-to-air — no supplemental water or refrigerant circuits needed at the cabinet level. This simplifies installation and reduces infrastructure dependencies for deployments that aren't colocated with in-row or overhead liquid cooling.

Integration & Compatibility

The TPE-24S is built for Vertiv E-series 24-inch cabinet enclosures and integrates with the iCOM CMS ecosystem. Before specifying this panel, verify the target cabinet's width and top-panel slot configuration. If your deployment includes Vertiv thermal management hardware such as in-row coolers or overhead cooling units, the iCOM integration allows centralized visibility into the full thermal stack — the panel becomes a monitored node rather than a passive component. For environments using managed network switching in the same cabinet row, iCOM compatibility reduces the number of separate monitoring interfaces required. Consult the Vertiv E-series cabinet documentation to confirm rail compatibility and top-panel mounting requirements for your specific enclosure configuration.

Frequently Asked Questions

Q: What cabinet width is the TPE-24S designed for?

A: The TPE-24S is designed for 24-inch (610mm) wide Vertiv E-series enclosures. It is not interchangeable with other width variants — confirm your cabinet's width specification before ordering.

Q: What is the sensible cooling capacity of the TPE-24S?

A: The TPE-24S carries a net sensible capacity of 19.5 Kbtuh (5.70 kW) and a total capacity of 21.8 Kbtuh (6.40 kW), with a nominal airflow of 885 CFM.

Q: Does the TPE-24S support monitoring and management integration?

A: Yes. The TPE-24S is compatible with Vertiv's iCOM Control and Monitoring System (CMS), which provides centralized visibility and management for cabinet-level thermal conditions alongside broader Vertiv cooling infrastructure.

Q: What heat rejection method does the TPE-24S use?

A: The TPE-24S uses air-to-air heat rejection — no water or refrigerant circuits are required at the cabinet level.

Q: Does the TPE-24S include cable entry knockouts?

A: Yes. The panel includes pre-scored knockout provisions for cable or conduit ingress, allowing top-entry cable runs without field-fabricating penetrations.

Eden Phillips
Eden Phillips

The TPE-24S is one of those components that gets overlooked in cabinet builds until a thermal problem surfaces — but its 885 CFM airflow rating and 19.5 Kbtuh (5.70 kW) net sensible capacity are not incidental numbers. In a 24-inch E-series cabinet carrying a dense compute or switching load, this panel is doing real thermal work at the top of the airflow column, and skipping or substituting it with a non-rated alternative can compromise the cabinet's overall thermal envelope in ways that don't show up until you're under full load.

Technical Highlights:

  • 19.5 Kbtuh / 5.70 kW Net Sensible Capacity: Sized for active compute loads — not just passive cable trays. If your cabinet is running near its thermal design point, this figure needs to match or exceed your row-level heat budget per unit.
  • 885 CFM Nominal Airflow: Enough throughput to avoid becoming the airflow bottleneck in a hot-aisle containment setup. Match this against your in-row or overhead cooler's CFM spec to confirm the top panel isn't the restriction.
  • iCOM CMS Integration: Brings the cabinet top panel into the same monitoring plane as Vertiv cooling infrastructure — thermal blind spots at the panel level are eliminated when iCOM is deployed across the row.

Deployment Considerations:

  • Confirm the target enclosure is a Vertiv 24-inch (610mm) E-series cabinet before ordering — Vertiv top panels are width-specific and not field-adaptable to other form factors.
  • The iCOM integration adds monitoring value, but only if iCOM CMS is already deployed in the environment; in non-Vertiv-managed sites, this capability goes unused and the panel functions as a passive rated component only.

The TPE-24S (often searched as TPE 24S) is the right specification for data center rows or network equipment rooms using Vertiv 24-inch E-series cabinets where thermal capacity at the cabinet top must be accounted for in the room's overall cooling design — particularly in deployments where iCOM is already managing in-row or precision cooling units.

Specifications
Total Nominal Capacity Kbtuh [Kw: 19.5 [5.70]
Net Sensible Capacity Kbtuh [Kw: 19.5 [5.70]
Nominal Airflow [Cfm: 885
Total Capacity: 21.8 [6.40]
Heat Rejection Medium: Air
Controls And Monitoring: iCOM CMS Monitoring & Management System
Dimensions: 610
Q&A
Reviews
Have Questions?

Vertiv TOP Panel Solid 24 in W E CAB Knockouts - TPE-24S

$130.00
$89.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources