APC by Schneider Electric the 2880VA Line Interactive 4U Rack/tower UPS Provides Pure - SMX3000LV

APC by Schneider Electric SMX3000LV 3kVA Line Interactive Rack/Tower UPSOverviewThe APC by Schneider Electric SMX3000LV is a 3kVA/2700W line-interacti…

$3,600.00 $2,396.99 SAVE $1203
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

APC by Schneider Electric the 2880VA Line Interactive 4U Rack/tower UPS Provides Pure - SMX3000LV

$3,600.00
$2,396.99

Overview

SKU: SMX3000LV
UPC: 731304292647
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric SMX3000LV 3kVA Line Interactive Rack/Tower UPS

Overview

The APC by Schneider Electric SMX3000LV is a 3kVA/2700W line-interactive UPS designed for IT rooms, data closets, and security infrastructure deployments where pure sine wave output and high efficiency are non-negotiable. Rated for 4U rack or tower installation, the SMX3000LV bridges the gap between lightweight office-grade UPS units and full three-phase power conditioning systems — it's the right size for mid-density server racks, NVR banks, or networked security equipment rooms. With a wide input voltage window of 70V to 153V and a 97.5% efficiency rating, this unit handles brown-outs and sags without unnecessarily switching to battery, and it does so without wasting meaningful energy in the process. For a full look at the Power & UPS category, explore options from compact single-phase units up to modular scalable systems.

Key Features

  • Pure Sine Wave Output at 2700W: Many devices — especially variable-frequency drive equipment, active PFC power supplies in servers, and surveillance NVRs — require true sine wave power to avoid hardware faults or premature component wear. The SMX3000LV delivers pure sine wave output under all conditions, including battery mode, so your connected equipment never sees the stepped approximation that cheaper units produce.
  • 97.5% Efficiency: At full load, the SMX3000LV converts input power to output at 97.5% efficiency. In a 24/7 security or IT deployment, that efficiency advantage over a 90–92% unit translates directly to lower heat output and reduced energy costs over a multi-year deployment cycle — measurable on a utility bill in dense rack environments.
  • Wide Input Voltage Range (70V–153V): The unit tolerates input as low as 70V before switching to battery. In facilities with aging electrical infrastructure or frequent brown-outs, this tolerance reduces unnecessary battery cycling — which directly extends battery service life and reduces maintenance intervals.
  • 10 AC Outlets Across Three NEMA Types: The outlet mix — NEMA 5-15R, NEMA 5-20R, and NEMA L5-30R — accommodates a wide range of connected equipment without requiring adapters. NEMA L5-30R is the twist-lock 30A output, appropriate for high-draw servers or sub-panel feeds; the standard 5-15R and 5-20R outlets cover workstations, switches, and lower-draw devices. The NEMA L5-30P power plug connects to matching twist-lock receptacles common in IT room PDU wiring.
  • Emergency Power Off (EPO): Built-in EPO support allows remote shutdown of connected equipment from a safety panel or fire control system. This is a hard requirement in many data center and secured facility deployments — confirm your facility's safety plan requires this before specifying a unit without it.
  • Output THD Under 5%: Total harmonic distortion on the output is kept below 5%, which matters for sensitive electronics that can exhibit erratic behavior or reduced lifespan when powered by a noisy waveform. Network switches, storage controllers, and precision measurement equipment all benefit from clean power in this range.
  • 540J Surge Energy Rating: The integrated surge suppression absorbs up to 540 joules of transient energy. This is line-of-defense protection against voltage spikes from switching events or nearby lightning — not a substitute for whole-building surge protection, but appropriate for point-of-use coverage of critical rack equipment.
  • 55 dB Audible Noise: At 55 dB, the fan and inverter noise is in the range of a typical office conversation. In a dedicated IDF or MDF closet this is unremarkable; in an open office or reception area, factor it into your placement planning.
  • Sealed Lead Acid (VRLA) Battery: The single VRLA battery cartridge is maintenance-free under normal operating conditions and doesn't require ventilation for off-gassing, making it appropriate for enclosed rack or closet installations. VRLA cells are field-replaceable, which matters for facilities managing runtime expectations over a multi-year service contract.
  • USB 2.0 Management Port: The USB 2.0 port supports connection to a host system for UPS monitoring and graceful shutdown management. Pair this with compatible UPS management software to automate shutdown sequences during extended outages — a practical necessity for unattended server rooms.

Integration & Compatibility

The SMX3000LV fits standard 19-inch rack enclosures at 4U and can also be deployed tower-orientation for floor or shelf mounting. The NEMA L5-30P input plug connects to 30A dedicated circuits, which is standard for mid-density rack power drops in commercial construction. The USB management interface is compatible with APC's PowerChute software family for automated graceful shutdown, runtime monitoring, and event logging. For deployments requiring network-based UPS management across multiple units, the SMX3000LV supports APC's AP9630/AP9631 Network Management Card (sold separately) via its SmartSlot interface — a common requirement in enterprise security operations centers managing distributed power infrastructure. When sizing for a network switch stack or NVR deployment, verify total connected load against the 2700W output capacity with sufficient headroom for startup current spikes. For guidance on sizing and runtime calculations, consult the UPS selection guide before finalizing your deployment plan. Explore the full APC by Schneider Electric line for complementary power distribution, management, and conditioning products.

Frequently Asked Questions

Q: What is the output waveform of the SMX3000LV — does it produce pure sine wave on battery?

A: Yes. The SMX3000LV delivers pure sine wave output in both line and battery modes. This makes it compatible with active PFC power supplies and variable-frequency drive equipment that can fault or degrade on stepped-approximation waveforms from lower-cost units.

Q: What input plug does the SMX3000LV use, and what circuit is required?

A: The SMX3000LV ships with a NEMA L5-30P twist-lock plug, which requires a dedicated 30A, 120V circuit. Confirm your rack room has a matching L5-30R receptacle on the appropriate circuit before installation.

Q: How many outlets does the SMX3000LV have, and what types?

A: The unit provides 10 AC outlets across three NEMA types: NEMA 5-15R (standard 15A), NEMA 5-20R (20A), and NEMA L5-30R (30A twist-lock). This variety lets you connect a mix of servers, switches, and high-draw devices without adapters.

Q: Does the SMX3000LV support EPO (Emergency Power Off)?

A: Yes. The SMX3000LV includes EPO support, allowing remote shutdown via an external safety panel or fire control system. This is a common compliance requirement in data centers and secured facilities.

Q: What is the runtime of the SMX3000LV during a power outage?

A: Runtime depends on connected load and is not fixed. The SMX3000LV ships with one internal VRLA battery cartridge. Runtime at full 2700W load will be shorter than at partial loads. For extended runtime, verify whether external battery packs are compatible with this model. Use APC's online runtime calculator with your specific connected load for accurate estimates.

Q: Can the SMX3000LV be monitored remotely over a network?

A: The unit includes a USB 2.0 port for local host management and supports APC's SmartSlot interface for an optional Network Management Card (such as the AP9630 or AP9631), enabling network-based monitoring, event logging, and remote shutdown management.

Eden Phillips
Eden Phillips

The SMX3000LV earns a spot in my standard recommendation set for mid-density security infrastructure rooms specifically because of that 70V–153V input window. I've deployed UPS units in older commercial buildings where brownouts regularly dip into the 85–90V range, and a unit with a narrow input window spends half its service life on battery — burning through battery capacity and generating unnecessary service calls. The SMX3000LV handles that range without complaint, which in practice means the VRLA cell lasts closer to its rated service interval instead of cycling out early.

Technical Highlights:

  • 97.5% Efficiency: In a continuously running deployment — say, a 10-camera NVR stack and associated switching gear drawing 1,800W — the difference between 90% and 97.5% efficiency is roughly 135W of waste heat eliminated. Over a year that's meaningful in both energy cost and thermal load on the room's HVAC.
  • Pure Sine Wave Under All Conditions: Active PFC supplies in modern servers and NVRs will fault or exhibit erratic behavior on modified sine wave output. The SMX3000LV's sine wave on battery removes that risk entirely — no need to audit which specific devices can tolerate a stepped waveform.
  • EPO Integration: The hard-wired EPO interface connects directly to facility safety systems. In a security operations center or access-controlled server room, this is often a code requirement — having it built in rather than bolted on via a relay hack is the cleaner installation.

Deployment Considerations:

  • The NEMA L5-30P input plug is non-negotiable — you need a dedicated 30A twist-lock circuit at the rack. If your facility has standard 20A duplex outlets at the rack row, that's a facilities project before this unit can go in. Budget the circuit upgrade into your timeline.
  • At 55 dB, this unit is acceptable in a closed IDF room but will be noticeable in a mixed-use space. If the installation site is adjacent to occupied office areas, factor acoustic treatment or a separate closet enclosure into the design.

For a physical security operations center running a mix of NVRs, managed PoE switches, and workstations — where pure sine wave is required, brownout tolerance is essential, and EPO is a facility code requirement — the SMX3000LV is the logical single-unit answer at the 3kVA class.

Specifications
Output power capacity: 3 kVA
Output power: 2700 W
Waveform: Sine
Input operation voltage (min: 70 V
Input operation voltage (max: 153 V
Input frequency: 50/60 Hz
Surge energy rating: 540 J
Efficiency: 97.5%
Emergency Power Off (EPO: Yes
Output voltage Total Harmonic Distortion (THD: 5%
Noise level: 55 dB
Audible alarm(s: Yes
AC outlet types: NEMA 5–15R, NEMA 5–20R, NEMA L5-30R
Power plug: NEMA L5-30P
AC outlets quantity: 10 AC outlet(s)
USB 2.0 ports quantity: 1
Battery technology: Sealed Lead Acid (VRLA)
Number of batteries supported: 1
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources