Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: SMT1500RMJ2U
UPC: 731304290445
Condition: New
Write a Review 32% OFF

APC Smart-ups 1200 Watts / 1200 VA Input 100V / Output 100V Interface Port S - SMT1500RMJ2U

APC by Schneider Electric SMT1500RMJ2U 1500VA Rack-Mount UPSOverviewThe APC by Schneider Electric SMT1500RMJ2U is a 1500VA / 1200W rack-mount uninterr…

$2,060.00 $1,399.99 SAVE $660
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

APC Smart-ups 1200 Watts / 1200 VA Input 100V / Output 100V Interface Port S - SMT1500RMJ2U

$2,060.00
$1,399.99

Overview

SKU: SMT1500RMJ2U
UPC: 731304290445
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric SMT1500RMJ2U 1500VA Rack-Mount UPS

Overview

The APC by Schneider Electric SMT1500RMJ2U is a 1500VA / 1200W rack-mount uninterruptible power supply engineered for 100V AC environments — a spec that targets Japan-market and select Asia-Pacific deployments where North American 120V units are not appropriate. In a 2U rackmount form factor, it delivers clean, conditioned output to connected loads, protecting security recorders, network switches, access control servers, and IP camera infrastructure from outages, sags, surges, and noise on the utility feed. If your rack lives in a facility running 100V nominal power, the SMT1500RMJ2U is one of the few APC Smart-UPS options purpose-built for that voltage — using a 120V unit here is not a substitution.

The Smart-UPS line is APC's commercial-grade workhorse. This model sits at the 1500VA capacity point, meaning it can sustain a 1200W continuous load — enough headroom to carry a multi-channel NVR, a PoE switch feeding a dozen cameras, and an access control server simultaneously, with runtime determined by your actual load versus battery capacity.

Key Features

  • 1500VA / 1200W Capacity: At 1200W continuous output, this unit covers realistic rack loads in a security or IT closet — a 300W NVR, a 150W PoE switch, two servers under moderate load, and ancillary gear — without pushing the UPS into thermal throttling territory. Size your load to 80% of rated capacity (960W) for reliable runtime and battery longevity.
  • 100V AC Input and Output: Nominal 100V AC in and out makes the SMT1500RMJ2U the correct choice for Japanese-standard facilities. Running mismatched voltage through a standard 120V UPS risks under-voltage conditions on the battery charger and incorrect AVR correction thresholds — this unit is calibrated for the 100V utility environment.
  • 6 x NEMA 5-15R Outlets: Six receptacles on the output strip give you individual circuit coverage for each protected device — NVR, switches, servers, and control panels — without requiring a downstream PDU in most small-to-mid deployments. NEMA 5-15R accepts standard 3-prong plugs common in 100V markets.
  • Battery Recharge Time Under 8 Hours: After a full discharge, the SMT1500RMJ2U returns to full battery charge in under 8 hours. In facilities with frequent short outages (utility flicker, scheduled shutdowns), this recharge window matters: if power restores at 6 AM and goes out again at noon, you want a full battery, not a partially recovered one.
  • USB and RS-232 Serial Interface: Dual management interfaces — USB and RS-232 — mean you can connect this UPS to a host server running PowerChute or compatible UPS management software for graceful shutdown scripting, runtime monitoring, and event logging. RS-232 is particularly relevant in environments where legacy servers or embedded controllers lack USB but have serial ports.
  • 2U Rack Form Factor: A 2U profile keeps rack real estate consumption low. In a 12U or 16U security equipment rack, 2U for UPS protection is a reasonable trade — leaving space for the NVR, switches, patch panels, and future expansion without forcing a larger enclosure.

Integration and Compatibility

The SMT1500RMJ2U integrates with APC's PowerChute software ecosystem via its USB or RS-232 interface, enabling automated graceful shutdown of connected servers and workstations when battery runtime drops below a configurable threshold. This is the critical protection layer beyond basic power continuity — a clean OS shutdown prevents filesystem corruption on NVRs and servers during extended outages.

The six NEMA 5-15R outlets accommodate standard security and IT equipment. Verify your connected devices draw no more than 1200W combined — a PoE switch at full 802.3af load across 24 ports (approximately 360W), an NVR at 50–150W, and two servers at 200–300W each approaches that ceiling. Calculate actual connected load before deployment; do not assume 1500VA translates to unlimited headroom.

For broader power protection options including higher-capacity models and three-phase units, review the full APC by Schneider Electric catalog. If your facility runs standard 120V North American power, a different Smart-UPS variant is the correct model — the SMT1500RMJ2U's 100V calibration is not adjustable. For rack infrastructure planning, see the rack power management category for PDUs, transfer switches, and environmental monitors that pair with this UPS. Security integrators planning camera and recorder deployments should also review network video recorders to correctly size UPS runtime against NVR power draw.

Frequently Asked Questions

Q: Is the SMT1500RMJ2U designed for 100V or 120V power environments?

A: The SMT1500RMJ2U is specifically designed for 100V AC nominal input and output. It is not the correct model for standard North American 120V deployments — use a 120V-rated Smart-UPS variant for those environments.

Q: How many outlets does the SMT1500RMJ2U provide?

A: Six NEMA 5-15R outlets. All are on the protected/battery-backed output circuit based on the product configuration.

Q: What management interfaces does the SMT1500RMJ2U support?

A: USB and RS-232 serial. Either interface connects to a host system running compatible UPS management software (such as APC PowerChute) for graceful shutdown, runtime monitoring, and event logging.

Q: How long does the battery take to recharge after a full discharge?

A: Less than 8 hours to full charge from a fully discharged state under normal conditions.

Q: What is the power capacity of the SMT1500RMJ2U?

A: 1500VA / 1200 watts. Plan connected load at no more than 80% of rated wattage (960W) for reliable runtime and to extend battery service life.

Q: What rack space does the SMT1500RMJ2U require?

A: 2U of rack space in a standard 19-inch rack enclosure.

James Everett
James Everett

The SMT1500RMJ2U comes up specifically when I'm scoping rack deployments in Japanese facilities or Asia-Pacific sites running 100V utility power — this is the detail that trips up integrators who source North American stock by default. The 100V nominal calibration on both input and output is not cosmetic; the AVR correction range and battery charger circuit are tuned for the 100V utility environment, so substituting a 120V Smart-UPS in this context creates real risk of chronic undervoltage events or charger underperformance.

Technical Highlights:

  • 1500VA / 1200W Rating: At 1200W continuous, you have enough capacity to carry a full security equipment rack — NVR, PoE switch, access control server, and ancillary gear — without pushing the unit above the 80% load ceiling (960W) that APC recommends for runtime reliability and battery longevity.
  • Dual Interface (USB + RS-232): Having both USB and RS-232 available means this unit integrates cleanly into both modern server environments and older embedded controllers or legacy NVR platforms that only expose a serial port. Graceful shutdown scripting via PowerChute is the real value here — not just ride-through, but clean OS shutdown before battery exhaustion.
  • Sub-8-Hour Recharge: In facilities with frequent short outages — utility flicker, planned maintenance windows — a recharge time under 8 hours keeps you protected through back-to-back events rather than sitting with a partially depleted battery after the first incident.

Deployment Considerations:

  • Verify your total connected load before commissioning. A 24-port 802.3af PoE switch at full load (~360W), a mid-range NVR (~100–150W), and two servers (~200W each) puts you near the 960W practical ceiling — add a UPS power meter or use the management interface runtime estimate before adding more devices.
  • The 100V output is not adjustable. If your facility ever transitions to 120V infrastructure, this unit cannot be reconfigured — plan for replacement rather than recalibration.

The SMT1500RMJ2U is the right specification call for a security or IT rack in a 100V Japanese-standard facility where the alternative is either a mismatched voltage unit or an expensive custom power conversion stage. It is not a general-purpose North American UPS — source it specifically for 100V deployments.

Specifications
Model: SMT1500RMJ2U
Input Voltage Range: 100 V AC Nominal
Output Voltage: 100 V AC Nominal
Outlets Outlets: 6 x NEMA 5-15R
Battery Recharge Time:
Interface: USBRS-232 Serial
Support Phone: 1-800-555-2725
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources