Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric SMX2000LVUS Line-Interactive 2000VA Rack/Tower UPS

Overview

The APC Smart-UPS X SMX2000LVUS is a 1800W / 1920VA line-interactive uninterruptible power supply designed for server rooms, network closets, and security infrastructure deployments where both rack mounting and tower placement are required from a single unit. At 4U of rack space with a 120V primary input, the SMX2000LVUS targets IT and physical security environments that need regulated, conditioned power without dedicating separate UPS hardware to every equipment bay. The 8 ft (2.4 m) input cable provides practical reach to wall or PDU outlets without extension cords. This unit is TAA-compliant, relevant for federal and government-connected deployments where Trade Agreements Act sourcing is a procurement requirement.

Key Features

  • 1800W / 1920VA Output Capacity: At 1800W true power output, the SMX2000LVUS can carry a fully populated 2U server, a mid-density NVR, and associated PoE switch load simultaneously — without hitting the derating cliff that trips up undersized UPS units. Know your actual watt draw, not just VA, before sizing: this unit delivers both figures clearly.
  • Line-Interactive Topology: Line-interactive regulation corrects voltage sags and swells in-line without switching to battery — critical in environments with unstable utility power (older buildings, industrial sites, secondary grid feeds). Battery cycles are preserved for genuine outages rather than burned on minor voltage fluctuations.
  • 4U Rack/Tower Convertible Form Factor: Ships ready for both orientations. In a rack, 4U is a meaningful footprint — factor that into your rack unit budget. Tower mode is useful in wiring closets or surveillance head-end rooms where rack infrastructure doesn't exist but floor or shelf space does.
  • 120V Primary Input (100V / 110V / 127V Also Supported): Native 120V for North American deployments, with additional input voltage acceptance at 100V, 110V, and 127V. This input flexibility means the unit can ride out utility fluctuations across a wider range without transferring to battery unnecessarily.
  • Lead-Acid Battery Chemistry: Sealed valve-regulated lead-acid (VRLA) batteries are the field-serviceable standard for this class of UPS — replacement batteries are widely available through established supply chains, and battery swap procedures don't require specialized tools or factory service.
  • 229W Battery Charger Rating: The 229W rated charge power means the battery recharges at a meaningful rate after a discharge event. For security deployments where the UPS may cycle during after-hours power events, faster recharge reduces the window of vulnerability before the next potential outage.
  • 8 ft (2.4 m) Input Cable: Long enough to reach a dedicated 20A circuit breaker panel or floor-level PDU from mid-rack position without daisy-chaining extension cords — a common installation shortcut that violates NEC and voids most UPS warranties.
  • TAA Compliance: Federal procurement officers and government contractors can source the SMX2000LVUS without a TAA waiver. For commercial integrators serving state, local, or federal end-users, this is a hard procurement gate — verify your end-user's requirements before substituting a non-TAA variant.

Integration & Compatibility

The SMX2000LVUS operates at 120V output matching standard North American rack equipment — compatible with servers, network switches, NVRs, VMS workstations, and access control panels drawing within the 1800W capacity envelope. As a line-interactive unit, it pairs naturally with power protection ecosystems including APC's own APC by Schneider Electric management cards and PowerChute network shutdown software (verify card compatibility against your specific expansion slot configuration). For security infrastructure build-outs, this UPS class is the standard pairing for network video recorders and associated switching gear where a controlled shutdown during extended outages protects recorded footage and database integrity. Integrators building out rack-mounted surveillance head-ends should also consider a rack power distribution layer between this UPS and downstream equipment to simplify per-outlet monitoring and load management.

Frequently Asked Questions

Q: Is the SMX2000LVUS TAA compliant?

A: Yes. The SMX2000LVUS is TAA (Trade Agreements Act) compliant, making it eligible for federal and government-affiliated procurement without requiring a sourcing waiver.

Q: What is the true watt output of the SMX2000LVUS?

A: The SMX2000LVUS delivers 1800W of true power output. The VA rating is 1920VA. Always size based on the watt figure — your connected equipment's actual watt draw must stay within 1800W.

Q: Can the SMX2000LVUS be used as a tower unit, or is it rack-only?

A: The SMX2000LVUS supports both rack and tower orientations. It occupies 4U in a standard rack or can be deployed as a tower unit on a shelf or floor — no additional conversion kit purchase required.

Q: What input voltage does the SMX2000LVUS accept?

A: The primary input is 120V (standard North American). The unit also accepts 100V, 110V, and 127V inputs, giving it useful flexibility across varying utility supply conditions.

Q: What battery type does the SMX2000LVUS use, and are replacement batteries field-serviceable?

A: It uses sealed lead-acid (VRLA) batteries. This is the standard serviceable chemistry for this UPS class — replacement batteries are widely available and can be swapped in the field without specialized equipment or factory service.

Q: What is the input cable length on the SMX2000LVUS?

A: The SMX2000LVUS ships with an 8 ft (2.4 m) input power cable — sufficient reach for most mid-rack to wall-outlet or PDU runs without using extension cords.

Marty Allison
Marty Allison

The SMX2000LVUS sits in the practical middle of the Smart-UPS X line — 1800W true output is enough to protect a densely loaded 4U NVR with dual redundant PSUs plus the access layer switch feeding it, without over-provisioning into a larger chassis that burns rack space you don't have. I've deployed this unit specifically in surveillance head-end racks where the alternative was a tower UPS sitting on the floor next to the rack: the 4U convertible form factor resolves that problem cleanly.

Technical Highlights:

  • 1800W True Power: At a 0.9375 power factor (1800W ÷ 1920VA), this UPS is rated closer to unity than budget line-interactive units — less derating headroom lost, more usable capacity for real loads.
  • 229W Battery Charger: A 229W charge rate means meaningful recharge speed after a partial discharge. For overnight or after-hours outage events, faster recharge reduces the vulnerability window before the next grid disturbance hits.
  • Multi-Voltage Input Acceptance (100–127V): In older commercial buildings where the utility feed runs low or high of nominal 120V, the wide input acceptance range keeps this unit on bypass regulation rather than transferring to battery — extending battery service life over a multi-year deployment.

Deployment Considerations:

  • TAA compliance is a hard gate for many government and education end-users — confirm your project's sourcing requirements before substituting the non-TAA SMX2000LVRM2U or similar variants, which may not satisfy procurement rules even if electrically identical.
  • At 4U, this unit consumes a meaningful slice of a 12U or 16U wiring closet rack. If your rack is already tight, verify U-count before committing — the tower orientation may be the better deployment path in constrained spaces.

The SMX2000LVUS is the right call for TAA-required rack deployments powering NVR + switching infrastructure in the 1000–1700W actual load range — federal facility surveillance head-ends, government network closets, and school district IDF rooms where procurement compliance and field-serviceable batteries both matter.

Specifications
Main Input Voltage: 120 V
Other Input Voltage: 100 V,110 V,127 V
Other Input Voltage: 100 V,110 V,127 V
Main Output Voltage: 120 V
Other Output Voltage: 100 V,110 V,127 V
Kw Rating: 1800 W
Rated Power In Va: 1920 VA
Number Of Rack Unit: 4U
Cable Length: 8 ft (2.4 m)
Battery Type: Lead-Acid battery
Battery Type: Lead-Acid battery
Battery Charge Power (Watts: 229 W rated
Color: Black
freight: 186.60
Q&A
Reviews
Have Questions?

APC by Schneider Electric SMX2000LVUS 2000VA Rack/Tower

$3,245.00
$2,178.99

RELATED PRODUCTS

Save $1,455.01
APC by Schneider Electric TAA APC Smart-ups X, Line Interactive, 2000VA, Rack/tower Convertible 4U, 100V
Add to Cart The item has been added

APC by Schneider Electric SMX2000LVNCUS

APC by Schneider Electric SMX2000LVNCUS 2000VA Rack/Tower

2000VA / 1800W line-interactive uninterruptible power supply built for IT closets, surveillance server rooms, and mid-size commercial equipment racks

    Usually Ships in 2-3 Weeks Free shipping over $499
    $4,350.00 $2,894.99 Save $1,455.01
    The item has been added Add to quote
    $4,350.00 $2,894.99 Save $1,455.01
    Save $1,455.01 Add to cart Add to quote
    Save $1,157.01
    APC Smart-ups X Line Interactive 2000VA Rack/tower Convertible 2U 100V-127V - SMX2KR2UNCX145
    Add to Cart The item has been added

    APC by Schneider Electric SMX2KR2UNCX145

    APC by Schneider Electric SMX2KR2UNCX145 2000VA Rack/Tower 2U

    2000VA line-interactive uninterruptible power supply built for IT closets, network equipment rooms, and security infrastructure deployments where

      Usually Ships in 2-3 Weeks Free shipping over $499
      $3,460.00 $2,302.99 Save $1,157.01
      The item has been added Add to quote
      $3,460.00 $2,302.99 Save $1,157.01
      Save $1,157.01 Add to cart Add to quote
      Save $989.01
      APC Smart-ups X 2000VA Rack/tower LCD - Line-interactive - 120 V - 1800WATT - SE - SMX2000LV
      Add to Cart The item has been added

      APC by Schneider Electric SMX2000LV

      APC by Schneider Electric SMX2000LV 2000VA Rack/Tower UPS

      2000VA/1800W line-interactive uninterruptible power supply built for rack or tower deployment where runtime flexibility, load visibility, and

        In stock · Ships same business day Free shipping over $499
        $2,955.00 $1,965.99 Save $989.01
        The item has been added Add to quote
        $2,955.00 $1,965.99 Save $989.01
        Save $989.01 Add to cart Add to quote
        Save $1,175.01
        APC Smart-ups X 2000VA Rack/tower 100-127V Taa-compliant - SMX2000RMLV2U-US
        Add to Cart The item has been added

        APC by Schneider Electric SMX2000RMLV2U-US

        APC by Schneider Electric SMX2000RMLV2U-US 2000VA Rack/Tower

        Line-interactive Uninterruptible Power Supply (UPS) designed to provide clean, reliable power to critical IT equipment

          Usually Ships in 2-3 Weeks Free shipping over $499
          $3,515.00 $2,339.99 Save $1,175.01
          The item has been added Add to quote
          $3,515.00 $2,339.99 Save $1,175.01
          Save $1,175.01 Add to cart Add to quote

          System Design, Deployment & Technical Support

          Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

          Fixed scope • Fixed price

          System Design Assistance

          • Get help validating product compatibility
          • Coverage requirements
          • Storage planning and deployment architecture before you buy.
          Request Design Help

          Deployment & Configuration Support

          • Access fixed-scope support for rollout planning
          • User setup guidance
          • Migration and system standardization across single-site or multi-site deployments
          View Support Services

          Guides, Tools & Calculators

          • PoE requirements
          • Storage retention
          • Camera selection and deployment methodology
          Open Technical Resources