APC by Schneider Electric Symmetra LX - Power Array - External - Online - AC 120/208/240 - SYA4K8P

APC by Schneider Electric SYA4K8P Symmetra LX External Power ArrayOverviewThe APC by Schneider Electric SYA4K8P is a modular, online double-conversion…

$18,725.00 $12,464.99 SAVE $6260
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

APC by Schneider Electric Symmetra LX - Power Array - External - Online - AC 120/208/240 - SYA4K8P

$18,725.00
$12,464.99

Overview

SKU: SYA4K8P
UPC: 731304222408
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric SYA4K8P Symmetra LX External Power Array

Overview

The APC by Schneider Electric SYA4K8P is a modular, online double-conversion power array delivering 4000 VA / 3200 watts of clean, conditioned power with a growth path to 8000 VA / 6400 watts — without replacing the chassis. Designed for enterprise UPS and power protection environments where downtime is measured in revenue and reputational cost, this unit produces a true sine wave output with less than 5% voltage distortion at full load, making it safe for sensitive loads that pulse-width-modulated approximations can damage over time. If you are sizing power infrastructure for a multi-server rack, a network operations center, or a surveillance recording stack, the SYA4K8P belongs on the short list.

The Symmetra LX architecture that underlies the SYA4K8P is built around field-scalability: the same external frame accepts additional power modules to reach the 8000 VA ceiling, so you are buying headroom, not just current capacity. An internal bypass — both automatic and manual — means maintenance does not require a controlled shutdown. An optional external bypass extends that flexibility further for facilities that need zero-interruption maintenance windows.

Key Features

  • 4000 VA / 3200 W initial capacity, scalable to 8000 VA / 6400 W: Commission the SYA4K8P at the power level you need today and add modules as loads grow. Scaling in-frame avoids a forklift chassis swap and the associated re-cabling downtime — a real operational advantage in live data center or surveillance headend environments.
  • True online double-conversion with sine wave output: Every connected load runs off the inverter continuously — the utility feed never touches your equipment directly. Output voltage distortion stays below 5% at full load and crest factor tolerance reaches up to 5:1, which handles the non-linear current draw of switching power supplies, servers, and network gear without degrading output quality.
  • Configurable output voltage — 120V, 208V, or 240V: Site power topology varies. The SYA4K8P accommodates 208V and 240V nominal output on the same chassis, with a hard-wire 4-wire (2PH + N + G) output connection. This matters in mixed-voltage facilities where a single UPS needs to serve both standard and high-density loads.
  • 208V nominal input with wide frequency acceptance (45–65 Hz, auto-sensing): The auto-sensing input handles utility frequency drift without manual reconfiguration — useful in international deployments or facilities on generator power where frequency can wander outside the standard 60 Hz band.
  • Input THD below 7% at full load: Low harmonic distortion back onto the utility feed keeps the SYA4K8P compliant with generator and shared-infrastructure requirements that cap harmonic injection — a spec that matters when the facility engineer reviews the load study.
  • Removable input/output wiring tray: Field wiring is accessible without disassembling the UPS. This cuts installation time on initial commissioning and, more importantly, simplifies every future maintenance visit — no need to power down adjacent equipment to access terminations.
  • Ships with modules installed: Pre-staging and factory acceptance testing can happen before the unit reaches the rack. For integrators commissioning remote sites, this means the unit can be tested at the bench, confirmed operational, then shipped to the final location without repeating a full commissioning sequence on-site.
  • Online thermal dissipation of 3,485 BTU/hr: At full load this unit pushes roughly 3,485 BTU/hr into the room. Factor this into your cooling budget — a row of these in a sealed equipment room without adequate airflow will trip thermal protection before you want it to.
  • Operating range 0–40°C, 0–95% RH, up to 3,000 meters elevation: The SYA4K8P covers most commercial and light-industrial installation environments. The 3,000-meter elevation ceiling covers high-altitude data center deployments without derating concerns below that threshold.
  • Internal automatic and manual bypass: Automatic bypass handles fault conditions without operator intervention. Manual bypass lets a technician take the UPS out of service for maintenance while loads remain on utility power — no planned outage required for routine service.

Integration and Compatibility

The SYA4K8P connects via hard-wire 4-wire (2PH + N + G) on both input and output, accepting 208V or 240V input and configurable for 208V, 240V, or 120V output. The output connection is a single hard-wire 4-wire circuit, so downstream distribution panels or PDUs handle branch circuit breakout. An optional external bypass is available for facilities requiring maintenance bypass at the room level rather than at the UPS chassis. The operating frequency window of 47–63 Hz on the output (synchronized to mains) and 45–65 Hz auto-sensing input makes this a workable fit alongside generator and transfer switch infrastructure where frequency regulation is less precise than utility grid. For enterprise deployments, pair with an APC network management card (sold separately) for SNMP-based monitoring, remote shutdown, and integration into data center infrastructure management platforms. Review the UPS selection and sizing guide for help matching load profiles to UPS capacity tiers before finalizing this or a larger Symmetra LX configuration.

Frequently Asked Questions

Q: What is the starting power capacity of the SYA4K8P and can it be expanded?

A: The SYA4K8P ships at 4000 VA / 3200 watts. The chassis supports expansion to a maximum of 8000 VA / 6400 watts by adding power modules — no chassis replacement required.

Q: What output voltages does the SYA4K8P support?

A: The SYA4K8P is configurable for 120V, 208V, or 240V nominal output voltage via a single hard-wire 4-wire (2PH + N + G) output connection.

Q: What is the input voltage and connection type?

A: The SYA4K8P accepts 208V nominal input (240V also supported) via a hard-wire 4-wire (2PH + N + G) input connection. Input frequency is auto-sensing across 45–65 Hz.

Q: Does the SYA4K8P include bypass capability?

A: Yes. The SYA4K8P includes both automatic and manual internal bypass. An optional external bypass is also available for facilities requiring room-level maintenance bypass without interrupting connected loads.

Q: What are the thermal output and operating environment requirements?

A: At full load, the SYA4K8P dissipates 3,485 BTU/hr. It operates in 0–40°C ambient temperature, 0–95% relative humidity (non-condensing), and up to 3,000 meters elevation.

Q: What does it mean that the SYA4K8P ships with modules installed?

A: The unit arrives with its power modules pre-installed, which allows bench staging and testing before deployment. This is particularly useful for integrators who want to pre-commission and verify the unit before shipping it to a remote or final installation site.

Eden Phillips
Eden Phillips

The SYA4K8P is the unit I reach for when a project starts at 4000 VA today but the facilities team cannot commit to final load figures — the in-frame scalability to 8000 VA / 6400 watts means you are not re-quoting a chassis swap in 18 months when the next server rack goes in. The double-conversion architecture with sub-5% output voltage distortion makes it a clean fit for mixed loads that include both computing infrastructure and sensitive network gear on the same bus.

Technical Highlights:

  • Scalable modular architecture (4000–8000 VA): The SYA4K8P grows within its own frame — adding capacity does not require new input/output wiring runs or a chassis changeout, which materially reduces the cost and risk of future capacity upgrades in occupied facilities.
  • Sine wave output, <5% THD, crest factor up to 5:1: This combination handles the peaked current draw of modern server and network power supplies without clipping or distortion. Units with inferior waveform specs can cause intermittent faults on sensitive loads under high-demand transients — the SYA4K8P's crest factor tolerance provides real margin here.
  • 3,485 BTU/hr full-load heat rejection: This is not a background number — it directly drives rack cooling design. At 3,485 BTU/hr per unit, a two-unit installation adds roughly 7,000 BTU/hr to the room heat load, which needs to be accounted for in CRAC unit sizing or in-row cooling layout before commissioning.

Deployment Considerations:

  • The hard-wire 4-wire input and output connections (2PH + N + G) mean this unit requires a licensed electrician for termination — it is not a plug-and-play install. Plan for electrical rough-in time and inspection in your project schedule.
  • Operating elevation ceiling is 3,000 meters. Above that threshold, derating applies — verify with the APC Symmetra LX technical documentation if your site elevation approaches or exceeds this limit before specifying the SYA4K8P.

The SYA4K8P is the right answer for a network operations center or multi-rack surveillance headend where load growth is expected but not fully quantified — the modular architecture absorbs that uncertainty without forcing a second capital purchase for the same infrastructure slot.

Specifications
Shippable With Modules Installed: Enables pre-installation UPS staging and testing and faster installation
Removable Input/Output Wiring Tray: Allows quick and easy installation and maintenance of the UPS Specs
Power Capacity: 3200 Watts / 4000 VA
Max Configurable Power: 6400 Watts / 8000 VA
Nominal Output Voltage: 120V,208V
Output Voltage Note: Configurable for 208 or 240 nominal output voltage
Output Voltage Distortion: Less than 5% at full load
Output Frequency (Sync To Mains: 47 - 63 Hz
Other Output Voltages: 240
Crest Factor: up to 5 : 1
Waveform Type: Sine wave
Output Connections: (1) Hard Wire 4-wire (2PH + N +G)
Bypass: Internal Bypass (Automatic and Manual),Optional External Bypass
Nominal Input Voltage: 208V
Input Frequency: 45 - 65 Hz (auto sensing)
Input Connections: Hard Wire 4-wire (2PH+N+G)
Other Input Voltages: 240V
Input Total Harmonic Distortion: Less than 7% for full load
Maximum Height: 671.00 mm
Maximum Width: 483.00 mm
Maximum Depth: 726.00 mm
Shipping Height: 914.00 mm
Shipping Width: 599.00 mm
Shipping Depth: 997.00 mm
Color: Black,Silver
Units Per Pallet: 1.00
Operating Environment: 0 - 40 °C
Operating Relative Humidity: 0 - 95%
Operating Elevation: 0-3000 meters
Storage Temperature: -15 - 45 °C
Storage Relative Humidity: 0 - 95%
Storage Elevation: 0-4500 meters
Online Thermal Dissipation: 3485.00 BTU/hr
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources