Image coming soon
Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Server Technology C2WG36TE-DQME2M66 Switched 3-Phase Rack PDU

Overview

The C2WG36TE-DQME2M66 is a Switched POPS Master PRO2 rack-mount power distribution unit built around a 208V, 3-phase delta input and 36 configurable ALT Phase HDOT outlets. It's designed for data center and server room racks where per-outlet switching and phase-balanced outlet placement matter more than a generic strip. If you're standardizing on Server Technology PDUs for a colo or enterprise rack build, the C2WG36TE-DQME2M66 fits environments needing high outlet density on a 3-phase circuit.

Key Features

  • 36 Configurable ALT Phase HDOT Outlets: HDOT (High Density Outlet Technology) alternates phases outlet-to-outlet, which lets you spread load evenly across a 3-phase circuit just by choosing adjacent outlets — fewer manual load-balancing calculations when racking mixed equipment.
  • 24 C13 Outlet Positions: C13 is the standard IEC inlet on most servers, switches, and network gear, so the bulk of a typical rack's power cords plug in without adapters.
  • 208V 3-Phase Delta Input: Matches standard North American data center 3-phase delta distribution, letting this PDU tie directly into existing rack power infrastructure without a step-down transformer.
  • Switched Outlet Control: Outlet-level switching (POPS Master PRO2 platform) supports remote power cycling of individual devices — useful for rebooting a hung server or network appliance without a physical visit to the rack.

Integration & Compatibility

As a 3-phase, C13-heavy outlet configuration, the C2WG36TE-DQME2M66 (often searched as C2WG36TE DQME2M66) is best matched to server and networking racks already wired for 208V 3-phase delta service — confirm your electrical infrastructure supports this input before ordering, since 3-phase delta and wye services are not interchangeable at the receptacle.

Frequently Asked Questions

Q: What input voltage and phase does the C2WG36TE-DQME2M66 require?

A: It runs on a 208V, 3-phase delta input.

Q: How many outlets does the C2WG36TE-DQME2M66 have, and what type?

A: It has 36 configurable ALT Phase HDOT outlets, including 24 C13 positions.

Q: What does HDOT outlet configuration mean for rack load balancing?

A: HDOT alternates phase assignment outlet-to-outlet, so adjacent outlets can be used to spread load across phases without manual mapping.

Q: Is the C2WG36TE-DQME2M66 a switched PDU?

A: Yes, it is part of the Switched POPS Master PRO2 line, which supports outlet-level switching.

James Everett
James Everett

The C2WG36TE-DQME2M66 is a 3-phase rack PDU I'd spec for a colo cage or server room already running 208V delta service — the 36-outlet HDOT layout is the detail worth understanding before you order.

Technical Highlights:

  • 36 ALT Phase HDOT Outlets: phase alternates by outlet position, so picking outlets in sequence balances load across all three legs without a separate load-mapping exercise.
  • 24 C13 Outlets: covers the majority of standard server and switch power cords directly, cutting down on adapter cables in the rack.
  • 208V 3-Phase Delta Input: matches common enterprise data center distribution, so it drops into existing 3-phase delta infrastructure.

Deployment Considerations:

  • Confirm your facility runs 3-phase delta (not wye) at 208V before ordering — the input configuration is not field-convertible.
  • With 24 of 36 outlets in C13 format, plan non-C13 loads (e.g., C19-corded PDU-fed switches) against the remaining outlet count before finalizing your rack elevation.

This is the outlet-dense, phase-balanced pick for a single high-density rack on 3-phase delta power — not a fit if your facility runs single-phase or 208V wye service.

Specifications
Outlet Configuration: 36 Configurable ALT Phase HDOT Outlets
Outlet Types: 24 C13
Voltage: 208V
Phase: 3PH
Brand: Server Technology
MPN: C2WG36TE-DQME2M66
Type: Power Supply
Q&A
Reviews

Server Technology Switched Pops Master PRO2 - C2WG36TE-DQME2M66

$4,215.00
$4,022.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources