Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Server Technology C2WG36TE-EPAF2N66 Switched Rack PDU

Overview

The Server Technology C2WG36TE-EPAF2N66 is a switched POPS-series power distribution unit built for 230V single-phase data center and network rack environments. It's rated for 32A on a 2P+PE (two-pole plus protective earth) circuit and delivers power through a mixed outlet bank of 12 CX-style connectors and 24 IEC C13 receptacles — a configuration aimed at racks running a blend of high-density server hardware and standard IEC-corded network gear on the same vertical strip. At 27 lbs, this is a full-length rack PDU, not a compact strip, and it's built to mount alongside the equipment it powers rather than sit as an afterthought in a spare rack unit.

Key Features

  • 230V / 32A 1PH rating: matches the higher-voltage, higher-current standard used in most non-US data center rack deployments and larger US facilities running 230V distribution — confirm your upstream panel and receptacle type support this before ordering, since it will not drop into a standard US 208V/120V circuit without the right feed.
  • 12xCX, 24xC13 IEC outlet mix: the CX outlets typically serve high-current or locking-style loads while the C13 bank covers standard IEC power cords on switches, servers, and NVR/network appliances — one PDU covering two connector standards means fewer strips per rack and less cable clutter on the vertical rail.
  • 2P+PE circuit breaker protection: a two-pole breaker with protective earth isolates both legs of the circuit on a fault and keeps the ground path intact, which matters for equipment safety compliance in a rack shared by multiple tenants or device classes.
  • 27 lb build: heavier gauge construction than a consumer power strip — expect a full vertical 0U mounting footprint rather than a horizontal rack-unit strip; plan cage nut or bracket mounting space in your rack elevation accordingly.
  • Switched outlet control: as a POPS (Per Outlet Power Sensing/Switching) switched unit, individual outlets can be power-cycled without touching the rest of the rack — useful when a single NVR, switch, or server needs a remote hard reboot and you don't want to drop power to neighboring gear.

Integration & Compatibility

This PDU is built for mixed-vendor racks: the C13 outlet bank covers the vast majority of switches, NVRs, and rack servers that ship with standard IEC C14 power cords, while the CX bank handles Server Technology's locking connector accessories where cord retention matters in high-vibration or frequently-serviced racks. Because outlet switching is controlled per-unit, plan your rack's power sequencing and remote-reboot workflow around individual outlet assignments rather than a single master switch. Confirm your facility's 230V 1PH 32A circuit and upstream breaker match this unit's input rating before specifying it for a build — mismatched voltage or phase is the most common ordering error on 230V-rated PDUs like the C2WG36TE-EPAF2N66 going into a US facility.

Frequently Asked Questions

Q: What input voltage and amperage does the C2WG36TE-EPAF2N66 require?

A: It's rated for 230V, single-phase (1PH), at 32A, protected by a 2P+PE circuit breaker.

Q: What outlet types does this PDU provide?

A: A mix of 12 CX-style outlets and 24 IEC C13 outlets on a single unit.

Q: How much does the C2WG36TE-EPAF2N66 weigh?

A: 27 lbs.

Q: Is this a switched PDU?

A: Yes — it's part of Server Technology's POPS switched PDU line, allowing per-outlet power control.

Marty Allison
Marty Allison

The C2WG36TE-EPAF2N66 is a 230V, 32A switched PDU with a 12xCX / 24xC13 outlet split — that outlet mix is the detail to size your rack around before anything else.

Technical Highlights:

  • 32A / 230V 1PH input: higher current headroom than a standard 20A strip, so it can carry a denser rack of network and server gear on one circuit — but confirm your panel is wired for 230V before ordering.
  • 2P+PE breaker: two-pole protection with a dedicated protective earth path, isolating both legs on a fault rather than just the hot leg.
  • 36-outlet total (12xCX + 24xC13): covers locking-style CX loads and standard IEC C13-corded switches/NVRs on one 27 lb unit, cutting down on the number of separate strips needed per rack.

Deployment Considerations:

  • This is a 230V-rated unit — it will not work on a standard US 120V/208V single-phase branch circuit without the correct 230V feed, so verify facility power before specifying it.
  • At 27 lbs and full outlet density, plan 0U vertical rack space and confirm your cabinet depth accommodates the mounting profile rather than treating it like a compact horizontal strip.

This is the right call for a 230V data center or telecom rack running a mixed CX/IEC equipment load that needs per-outlet switching for remote reboots — not a fit for a standard US 120V network closet build.

Specifications
Manufacturer: Server Technology Inc
Weight: 27.00 lbs
Input Voltage: 230V
Phase: 1PH
Amperage Rating: 32A
Outlet Type: 12xCX, 24xC13 IEC
Circuit Breaker: 2P+PE
Runtime: 6HR
Brand: Server Technology
MPN: C2WG36TE-EPAF2N66
Type: Mounting Bracket
Q&A
Reviews

Server Technology Switched Pops Expansion - C2WG36TE-EPAF2N66

$3,688.00
$3,518.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources