Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
Server Technology C2W48TE-5CAE2M99 Switched Rack PDU, 415V 30A
The Server Technology C2W48TE-5CAE2M99 is a Switched MASTER PRO2 rack power distribution unit built for 415V three-phase data center environments where per-outlet control and phase-balanced load management matter more than a basic power strip. Configured with 30 C13 outlets and HDOT (High-Density Outlet Technology) receptacles, this PDU targets high-density server cabinets and colo deployments running mixed IT gear on a single vertical or horizontal rail. The C2W48TE-5CAE2M99 pulls input through a NEMA L22-30P plug rated for 30A, giving facilities teams a locking, twist-style connection that resists accidental disconnects in busy cabinet environments.
Overview
This unit is built around a 415V input with a rated operating current of 24A and a total input power capacity of 17.3 kW — enough headroom to run a fully populated rack of switches, servers, and NVR appliances off one distribution point without tripping upstream breakers. The 50/60 Hz frequency rating means it installs cleanly across North American and international electrical standards without a separate SKU per region. As part of the broader Server Technology power distribution line, the C2W48TE-5CAE2M99 fits environments already standardized on Server Technology's switched and monitored PDU architecture.
Key Features
- 30x C13 Outlets: High outlet density means one PDU covers a full cabinet of servers, switches, and small-form IT devices without daisy-chaining a second unit — fewer cables in the rack, fewer failure points.
- HDOT Outlet Technology: High-Density Outlet Technology physically secures each C13 plug in place, reducing accidental unseating during cable management or adjacent equipment service — a real problem in crowded 42U racks.
- Configurable Alt Phase Layout: Outlets are arranged for phase balancing across a 415V three-phase feed, letting facilities staff distribute load evenly instead of overloading a single leg.
- 415V Input, 24A Rated / 30A Plug: The 24A rated current against a 30A NEMA L22-30P plug leaves a working safety margin under continuous load — important for 24/7 data center duty cycles rather than intermittent office use.
- 17.3 kW Input Power Capacity: Supports dense rack configurations — blade chassis, multiple 1U servers, and PoE switches — on a single distribution point instead of splitting the load across two lower-capacity units.
- 50/60 Hz Frequency Support: One SKU works on both 50Hz and 60Hz utility power, simplifying sourcing for multi-region deployments instead of tracking region-specific part numbers.
- C13 Outlet Rating (≤12A @ 240V L-N, 15A Peak): Each outlet is individually rated to protect connected IT gear from overcurrent while still accommodating brief inrush spikes at power-on — relevant when a rack full of servers boots simultaneously after an outage.
- Switched Architecture: Outlet-level switching (per the MASTER PRO2 product family) supports remote power cycling of individual devices — useful for rebooting a hung server or switch without a site visit.
Integration & Compatibility
The C2W48TE-5CAE2M99 is built for cabinets already wired for 415V three-phase distribution, common in enterprise data centers and colocation facilities rather than standard 120V office racks. Pair it with properly rated power distribution accessories and confirm upstream breaker sizing against the 24A rated current before commissioning. Because this is a 415V/three-phase unit, it is not a drop-in replacement for a 120V single-phase PDU — verify your cabinet's electrical service before ordering. For facilities planning a broader power and rack refresh, review a PoE and power planning guide before finalizing outlet count and phase distribution across multiple PDUs in the same row.
Frequently Asked Questions
Q: What input voltage does the C2W48TE-5CAE2M99 require?
A: It runs on 415V input at 50/60 Hz, terminated with a NEMA L22-30P 30A locking plug.
Q: How many outlets does the C2W48TE-5CAE2M99 have?
A: It provides 30 C13 outlets using HDOT (High-Density Outlet Technology) receptacles.
Q: What is the maximum power capacity of the C2W48TE-5CAE2M99?
A: The unit is rated for 17.3 kW total input power capacity, with a 24A rated input current against the 30A plug rating.
Q: What is each C13 outlet rated for on the C2W48TE-5CAE2M99?
A: Each C13 outlet is rated at up to 12A at 240V line-to-neutral, with a 15A peak allowance.
Q: Is the C2W48TE-5CAE2M99 (often searched as C2W48TE 5CAE2M99) suited for single-phase 120V racks?
A: No — this unit is built for 415V three-phase input and is not compatible with standard 120V single-phase electrical service.

What jumps out on the C2W48TE-5CAE2M99 is the outlet density paired with the phase-balanced layout — 30 C13 positions on a 415V feed is built for a fully loaded cabinet, not a half-empty test rack. If you're speccing this for a colo build, the 24A rated current against a 30A L22-30P plug is the number to plan your breaker sizing around.
Technical Highlights:
- 17.3 kW input power capacity: Covers a dense mix of 1U servers and switches on one PDU — I've seen undersized PDUs force a second unit into a rack that had the U-space but not the power headroom.
- HDOT receptacles: The high-density outlet retention matters more than it sounds in a live rack — I've had standard C13 outlets walk loose from vibration and cable tug over time; HDOT is specifically built to resist that.
- 30A NEMA L22-30P input plug: Locking twist-lock connector — confirm your PDU whip or receptacle in the cabinet matches this pattern before the unit ships, since it's not a standard C14/C20 IEC input.
Deployment Considerations:
- This is a 415V three-phase unit — verify your facility's electrical service type before ordering; it will not work on a standard 120V/208V single-phase circuit.
- With 30 outlets rated at up to 12A each but a 24A total rated input current, you're managing aggregate load across all outlets, not treating each outlet as independently capable of its full rating simultaneously — plan your per-outlet draw accordingly.
This is the right call for a European or Asia-Pacific colocation cabinet running 415V three-phase house power with a dense mix of switches and 1U/2U servers that need individual outlet-level control — not for a domestic 120V server closet.
Compare with similar
Server Technology Switched Master PRO2 (30) - C2W48TE-5CAE2M99
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Server Technology products? Shop the full Server Technology catalog →
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology