Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
Server Technology C2W48TE-DQME2M99 Switched 48-Outlet 3-Phase PDU
Overview
The Server Technology C2W48TE-DQME2M99 is a switched Primary Pro2 rack power distribution unit built around 48 configurable alternating-phase Hdot outlets, running on 208V 3-phase input. It's designed for data center and server room racks where you need outlet-level control across three phases rather than a single dumb power strip. This is a switched PDU, not a monitored or metered strip — the core value is remote on/off control per outlet bank, not usage data.
Key Features
- 48 Configurable Alt Phase Hdot outlets: Alternating-phase outlet placement lets you distribute connected equipment evenly across all three phases as you cable the rack, which keeps phase loads balanced instead of stacking load on one leg — a common cause of nuisance breaker trips in dense racks.
- 208V 3-phase input: Matches standard North American data center 3-phase distribution, so it drops into existing 208V infrastructure without a step-down or separate transformer.
- Switched outlet control: Outlets can be power-cycled without a technician walking the row, which cuts truck-rolls for hung servers or network gear that just needs a hard reset.
- High outlet density (48): One C2W48TE-DQME2M99 can cover a full rack or two half-populated racks, reducing the number of PDUs — and the number of network drops for management — you need to provision per row.
Integration & Compatibility
The C2W48TE-DQME2M99 (often searched as C2W48TE DQME2M99) belongs to Server Technology's Primary Pro2 switched PDU line. If your rack runs single-phase 120V/208V equipment only, confirm outlet compatibility against your gear's plug type before ordering — configurable Hdot outlets are flexible but the exact receptacle mix should be verified against the specific unit configuration. For environments that need outlet-level current monitoring rather than switching alone, ask about a metered or monitored variant in the same power products line rather than assuming this switched model reports usage data.
Frequently Asked Questions
Q: What voltage and phase does the C2W48TE-DQME2M99 run on?
A: 208V, 3-phase input.
Q: How many outlets does the C2W48TE-DQME2M99 have?
A: 48 configurable alternating-phase Hdot outlets.
Q: Is the C2W48TE-DQME2M99 a monitored or switched-only PDU?
A: It's a switched PDU (Primary Pro2 Switched series) — outlets can be turned on and off remotely. Evidence does not confirm outlet-level power monitoring for this specific model.
Q: Will the C2W48TE-DQME2M99 balance load across all three phases?
A: Yes — the alternating-phase Hdot outlet layout is designed to let you spread connected loads evenly across the three phases as equipment is plugged in.

The C2W48TE-DQME2M99 is a 48-outlet switched PDU, and the detail worth calling out is the alternating-phase Hdot outlet arrangement on a 208V 3-phase feed.
Technical Highlights:
- 48 outlets, alternating phase: outlets are physically interleaved across the three phases so you balance load naturally as you populate the rack top to bottom, instead of having to track phase assignment on a spreadsheet.
- 208V 3-phase input: standard data center distribution voltage — no step-down transformer or separate single-phase feed needed on typical US commercial power.
- Switched control: remote outlet power cycling on a PDU this dense means one unit can cover a full rack without a technician physically touching every device.
Deployment Considerations:
- Confirm the specific outlet/receptacle configuration against your equipment's power cords before ordering — 'configurable' outlet PDUs ship in multiple receptacle mixes.
- This listing doesn't specify amperage rating or physical mounting depth — verify branch circuit rating and rack unit height fit against your specific rack before final quoting.
Reasonable fit for a data center row needing dense outlet-level switched power on 208V 3-phase circuits, where balancing load across phases in a single rack matters more than per-outlet metering.
Compare with similar
Server Technology Switched Primary PRO2 (48) - C2W48TE-DQME2M99
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Server Technology products? Shop the full Server Technology catalog →
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology