Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
Server Technology C2X36CE-DQME2M66 0U Switched Rack PDU
The C2X36CE-DQME2M66 is a 0U vertical switched power distribution unit built for data center racks that need high-density outlet counts without eating into usable rack space. Rated for 208V 3-phase delta input at 60A, it delivers up to 17.3kW of total power capacity across 36 outlets — a configuration sized for dense server or network racks where a single 1U or 2U horizontal PDU would run out of outlets fast.
Overview
This C2X36CE-DQME2M66 unit is part of the Server Technology PRO2 Switched product series, built around 3-phase power delivery and a 0U rackmount form factor that mounts vertically along the rear of the rack rail rather than consuming horizontal rack units. That matters most in racks already tight on 1U/2U space for compute or switching gear.
Key Features
- 36 total outlets (24× IEC C13 + 12× IEC C19): the C13/C19 mix covers both standard servers and higher-draw equipment like blade chassis or larger switches on the same strip, so you're not running a separate PDU for high-current gear.
- 17.3kW total power capacity: sizing headroom for dense racks running multiple servers plus networking gear without splitting the load across two PDUs.
- 208V 3-phase delta input: matches standard data center 3-phase distribution, balancing load more evenly across phases than a single-phase feed at equivalent capacity.
- 60A input current with IEC 60309 3P+PE input connector: a locking industrial-grade input connector rated for the full 60A draw — reduces the risk of accidental disconnect under vibration or cable movement compared to a standard plug.
- 10ft input cord: enough reach to route to an overhead busway or PDU whip without an extension, though rack position relative to the power source is worth checking before ordering.
- 0U rackmount form factor: mounts vertically, so it doesn't compete with servers and switches for horizontal U space — a real factor in fully populated racks.
- 50/60 Hz frequency support: works on both North American and international 50Hz distribution without a separate SKU.
Integration & Compatibility
As a switched PDU, this unit is intended for racks where remote outlet-level control and monitoring are part of the power management plan — a fit for data center or network components deployments already standardizing on managed power. Confirm your upstream panel and whip are provisioned for 208V 3-phase 60A service before ordering, since 3-phase delta input isn't interchangeable with single-phase or wye-configured circuits.
Frequently Asked Questions
Q: What input voltage and phase configuration does the C2X36CE-DQME2M66 use?
A: It runs on 208V AC, 3-phase delta input, rated at 60A through an IEC 60309 3P+PE connector.
Q: How many outlets does the C2X36CE-DQME2M66 have and what type?
A: 36 total outlets: 24× IEC C13 and 12× IEC C19.
Q: What is the total power capacity of the C2X36CE-DQME2M66?
A: 17.3kW.
Q: Does the C2X36CE-DQME2M66 mount in a standard rack?
A: Yes — it's a 0U rackmount unit, meaning it mounts vertically and does not consume horizontal rack unit space.
Q: How long is the input power cord on the C2X36CE-DQME2M66?
A: 10ft.

The C2X36CE-DQME2M66 (often searched as C2X36CE DQME2M66) is a 3-phase delta PDU, and that detail changes how you plan the circuit — it's not a drop-in swap for a wye-configured feed, so verify your panel output before this ships.
Technical Highlights:
- 17.3kW capacity at 60A/208V 3-phase: gives you real headroom in a fully loaded rack running mixed compute and network gear off one strip.
- 36-outlet mix (24× C13 + 12× C19): the C19 outlets matter for anything drawing more than a standard server load — blade enclosures, larger switches — without needing a second PDU.
- 0U vertical form factor: frees every U of rack space for compute instead of power distribution, which adds up fast in a 42U rack.
Deployment Considerations:
- The IEC 60309 3P+PE input connector and 60A rating mean your upstream whip or panel circuit needs to match exactly — this isn't a standard NEMA plug-in.
- The 10ft input cord is fixed; measure the run from your PDU/whip drop to the rack before assuming it reaches, especially in end-of-row cabinet positions.
This is the right unit for a data center operator standardizing a row of racks on 3-phase delta power who needs outlet-level density (36 ports) without sacrificing rack U space — not a fit for facilities running single-phase 120/208V wye distribution.
Compare with similar
Server Technology Switched Link PRO2 (36) - C2X36CE-DQME2M66
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Server Technology products? Shop the full Server Technology catalog →
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments