Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Middle Atlantic LP-61320 is a 2U horizontal rackmount power distribution unit designed for AV, security, and IT rack builds that require controlled outlet management across 16 individually switched NEMA 5-20R receptacles on a single 30A/120V circuit. If you're building out a rack where unplanned reboots or outlet-level power cycling needs to happen without rolling a technician to the cabinet, this is the unit to evaluate. It draws from an L5-30P twist-lock input — a deliberate choice that prevents accidental disconnection under load in a live rack environment.
The LP-61320 (often searched as LP 61320) ships in a black and silver finish at 17.2 in wide × 3.5 in tall × 5.2 in deep — a standard 2U 19-inch rack footprint that drops into almost any commercial equipment enclosure without clearance compromises. The 9.84 ft (3 m) power cord gives you genuine reach to a floor PDU or in-row UPS without daisy-chaining extension cords, which is a real-world wiring consideration in deeper two-post or four-post racks.
The LP-61320 connects to any infrastructure with a 30A/120V NEMA L5-30 receptacle — standard output on commercial UPS units (APC, Eaton, Vertiv) in the 1.5–3 kVA range, as well as dedicated 30A wall receptacles common in data centers and IDF closets. The NEMA 5-20R receptacles accept both 5-15P and 5-20P plugs, so standard 15A equipment (cameras, switches, encoders) and 20A devices both connect without adapters. This is a horizontal-mount unit and does not install vertically on a rack rail — confirm your rack layout supports front- or rear-horizontal PDU mounting before ordering. For rackmount power planning in larger deployments, review your PoE switch power budgets alongside PDU capacity to avoid oversubscription on the 30A feed. Middle Atlantic's broader rack power and infrastructure line includes vertical PDUs, UPS units, and cable management accessories if your build requires a different form factor.
Q: What plug type does the LP-61320 require at the power source?
A: The LP-61320 uses an L5-30P twist-lock plug, which requires a NEMA L5-30R receptacle at the power source. This is a 30A/120V locking connector — confirm your UPS, PDU, or wall outlet is equipped with an L5-30R before installing.
Q: How many outlets does the LP-61320 have, and what receptacle type?
A: The LP-61320 provides 16 NEMA 5-20R receptacles. These accept both 5-15P (standard 15A) and 5-20P (20A) plugs, so most rack equipment connects without adapters.
Q: Is the LP-61320 TAA compliant for government procurement?
A: Yes. The LP-61320 is TAA (Trade Agreements Act) compliant, making it eligible for U.S. federal, GSA schedule, and qualifying state/local government purchases where TAA compliance is required.
Q: What is the maximum power capacity of the LP-61320?
A: The LP-61320 is rated for 30A at 120V, yielding a maximum of 3,600W. Per the NEC 80% continuous-load rule, the practical sustained load ceiling is 2,880W (24A). Plan your rack load accordingly.
Q: Does the LP-61320 fit a standard 19-inch rack?
A: Yes. At 17.2 in wide and 3.5 in tall (2U), the LP-61320 mounts in any standard 19-inch EIA rack in a horizontal orientation. Rack depth requirement is minimal at 5.2 in.
Q: How long is the power cord on the LP-61320?
A: The LP-61320 includes a 9.84 ft (3 m) corded feed, giving sufficient reach to a floor-level or in-row UPS without requiring extension cords.

The LP-61320 is the unit I spec when a rack integrator needs switched outlet control across a 30A feed and can't afford the failure mode of an accidental power disconnect mid-shift. That L5-30P twist-lock input is the detail that separates this from a basic strip — in a production security head-end, one bump of a straight-blade cord costs you a full camera reboot across 16 channels.
Technical Highlights:
Deployment Considerations:
This unit fits well in physical security head-end rooms, network IDF closets, and government facility racks where switched outlet control, a TAA pedigree, and a locking input are non-negotiable requirements on the same line item.