Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: STI-1200-ES
UPC: 662950120001
Condition: New
Availability: Special Order · Usually Ships in 2-3 Weeks
Warranty Manufacturer Warranty
Write a Review 37% OFF

STI Stopper II® Sin Sirena Para montaje a Ras - STI-1200-ES

STI STI-1200-ES Silent Sounder Flush Mount Overview The STI-1200-ES is a silent (sin sirena) sounder module purpose-built for access control strike as…

$86.81 $54.99 SAVE $32
Special Order
Ships in 2-3 Weeks

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

STI Stopper II® Sin Sirena Para montaje a Ras - STI-1200-ES

$86.81
$54.99

Overview

SKU: STI-1200-ES
UPC: 662950120001
Condition: New
Availability: Special Order · Usually Ships in 2-3 Weeks
Warranty Manufacturer Warranty

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

STI STI-1200-ES Silent Sounder Flush Mount

Overview

The STI-1200-ES is a silent (sin sirena) sounder module purpose-built for access control strike assemblies and door hardware where audible alarm signals are either undesirable or restricted by facility policy. This flush-mount component integrates directly into STI Stopper II® door security assemblies and connects via polarity-marked axial leads to your access control panel's sounder output. Silent operation makes it the right choice for libraries, hospitals, high-security offices, and any facility where restricting audible alarms in specific zones is a compliance or operational requirement.

Key Features

  • Flush-mount cavity design: Sits recessed into door frame or strike assembly mounting cavities, maintaining a clean aesthetic and eliminating external protrusions that could catch on clothing or equipment during entry.
  • Polarity-marked axial leads: Color-banded lead termination clearly marks cathode end, preventing reversed-polarity installation that would cause component failure. Strict polarity observation is mandatory during panel wiring.
  • Compact form factor: Weighs approximately 369 mg and is small enough for integration into standard strike frame cavities without requiring structural modifications to the door assembly.
  • Direct panel integration: Connects to access control panel sounder outputs via simple two-conductor wiring—no separate power supply or relay interface required. Reduces BOM complexity in modular door security ecosystems.
  • Silent operation: No audible alarm output; deployment is ideal for facilities restricting noise in sensitive zones or where silent visual confirmation is preferable to acoustic signals.
  • Stopper II® family compatibility: Designed for STI strike assemblies and door hardware mounting systems that accept the Stopper II sounder interface. Verify mounting cavity dimensions and wiring harness termination before ordering to confirm fit with your specific door assembly revision.

Integration and Compatibility

The STI-1200-ES pairs with STI access control strike hardware and Stopper II® door assemblies. Confirm compatibility with your door frame's mounting cavity envelope and wiring termination style before purchase. This device is designed for integrated access control ecosystems where silent operation aligns with facility security policy—common in healthcare, legal, library, and high-security office environments. The component requires only standard access control panel sounder output wiring; no additional relays, drivers, or power conditioning are needed.

Installation Notes

Mount the STI-1200-ES flush into the designated sounder cavity of your strike assembly or door frame. Connect the polarity-marked leads directly to your access control panel's sounder output, observing the color band to identify the cathode end and ensuring correct positive/negative assignment. Route wiring cleanly from the cavity to the control panel to avoid pinching or damage during strike operation. Standard wiring practices apply—no specialized tools or crimping equipment are required beyond a basic multimeter for polarity verification. Test the sounder circuit continuity before final door assembly closure to confirm lead connectivity.

What's in the Box

The STI-1200-ES ships as a single sounder module with polarity-marked axial leads. No additional mounting hardware, fasteners, or connectors are included; these are typically sourced as part of the complete strike assembly kit.

Frequently Asked Questions

Q: Is the STI-1200-ES compatible with my existing STI access control strike assembly?

A: The STI-1200-ES is designed for STI Stopper II® family door hardware. Confirm that your strike assembly has a mounting cavity sized for the sounder module and that wiring termination matches the axial-lead polarity-marked interface. Check your strike documentation or contact your integrator if unsure about revision compatibility.

Q: What happens if I reverse the polarity when wiring the STI-1200-ES?

A: Reversed polarity will damage the component. Always observe the color band marking on the axial leads to identify the cathode end, and verify positive and negative assignments from your access control panel's sounder output before final connection. Use a multimeter to confirm polarity if wiring documentation is unclear.

Q: Does the STI-1200-ES produce any audible alarm sound?

A: No. The STI-1200-ES is a silent (sin sirena) sounder module—it has no speaker or acoustic output. It is designed for facilities where audible alarms are prohibited or undesirable in specific zones.

Q: What voltage does the STI-1200-ES require?

A: The STI-1200-ES operates on the sounder output voltage supplied by your access control panel. Confirm your panel's sounder output voltage specification (typically 12V DC or 24V DC) before installation. See your panel documentation for the correct sounder output rating.

Q: Can the STI-1200-ES be installed outside the door frame cavity?

A: The STI-1200-ES is designed for flush-cavity mounting. Mounting outside the intended cavity will expose the axial leads and connector, increasing risk of mechanical damage, moisture ingress, and unintended contact. Install only in the designated sounder mounting cavity of your strike assembly.

Q: What is the warranty on the STI-1200-ES?

A: Warranty information is provided by STI. Contact STI or consult your sales documentation for the current manufacturer warranty period and coverage terms.

Marty Allison
Marty Allison

I specify the STI-1200-ES when a facility's access control policy explicitly prohibits audible alarms in sensitive zones but still requires electrical confirmation of strike activation at the panel. The polarity-marked axial lead design is the critical detail here—it forces intentional wiring discipline during integration, reducing the risk of field-swapped sounder modules that would fail silently and mask strike faults during commissioning.

Technical Highlights:

  • Polarity-marked axial leads: The color-banded cathode marking eliminates guesswork during panel termination. Reversed polarity is the leading cause of sounder module failure on retrofit jobs; this design enforces correct orientation at first assembly and during any future replacement cycles.
  • Flush-cavity form factor: At approximately 369 mg with a recessed envelope, the STI-1200-ES fits into standard strike assembly cavities without modification. This matters on retrofit projects where door frame cavities are already dimensioned for Stopper II® hardware—no structural rework needed.
  • Silent operation: Zero acoustic output makes this the only choice for compliance-driven environments. Healthcare facilities restricting alarm noise in patient areas, legal offices managing client confidentiality, and high-security spaces isolating sensitive zones all depend on this non-signaling design to avoid cross-zone audible leakage that could compromise operational security.

Deployment Considerations:

  • Confirm your access control panel's sounder output voltage (typically 12V or 24V DC) matches the STI-1200-ES operating specification before wiring. Panel datasheet will specify sounder output rating—mismatched voltage is a failure risk during first power-up.
  • Silent operation means no acoustic feedback to door users or staff. In environments where users expect an audible confirmation of strike release, add documentation or signage indicating the sounder is functional but silent. Without expectation-setting, integrators sometimes receive false trouble calls from end-users who assume the device is broken because they heard nothing.

Deploy the STI-1200-ES in healthcare, legal, library, and classified office environments where facility policy mandates silent access control feedback. The polarity-marked lead design and flush-cavity integration make it low-friction for STI-based systems, but confirm strike assembly revision compatibility and sounder output voltage before ordering to avoid integration delays.

Specifications
Product Type: Protective Cover
Polarity: color band denotes cathode end 
Weight: approx. 369 mg
Type: Sirena Para montaje Ras, Español
Product_Type: Silent sounder module
Brand: STI
MPN: STI-1200-ES
Strike_Type: STI Stopper II®
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources