Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit FRFWCSC12LYL FiberRunner 4-Way Cross Split Cover

Overview

The Panduit FRFWCSC12LYL is a 4-way cross split cover designed specifically for the Panduit FiberRunner 12x4 system. At 22.25 inches long and 2.88 inches tall, this yellow polycarbonate/ABS cover closes over 4-way cross fittings in the runway — but the split design is what makes it worth specifying over a solid cover: each side opens independently, so you can add or remove fiber cables mid-run without pulling the entire cover off the fitting. In high-density data center rows where cross fittings tie together multiple fiber runs, that access matters every time a circuit changes.

Engineered for fiber routing management in data centers and central telecommunications offices, the FRFWCSC12LYL pairs directly with the FiberRunner 12x4 pathway system. The yellow color coding follows standard fiber-routing identification conventions — useful in facilities where multiple pathway systems coexist and color-differentiation speeds up moves, adds, and changes.

Key Features

  • Split cover design (4-way cross access): The cover separates at each branch of the cross fitting, creating dedicated openings for adding and removing cables. In practice, this means a technician can break into one leg of the cross without disturbing active fiber in the other three — a meaningful time saving on live facilities where touching neighboring runs carries risk.
  • 22.25-inch overall length: Sized to span the full length of a 12x4 cross fitting with coverage to spare. Correct cover length is what prevents gap exposure at the fitting transition — undersized covers leave fiber exposed to snagging during cable pulls.
  • 2.88-inch height (73.2 mm): The low-profile form factor keeps the covered cross fitting within the vertical envelope of the FiberRunner cable management system, so adjacent ladder rack or overhead structure clearance isn't compromised.
  • Polycarbonate/ABS construction: This material combination delivers impact resistance without the brittleness of straight polycarbonate — relevant in facilities where heavy patch cords rest on cover surfaces or carts occasionally contact the overhead pathway. It also holds color stability under fluorescent and LED lighting without yellowing over time.
  • RoHS compliant: Meets the EU Restriction of Hazardous Substances directive — required documentation for facilities with environmental compliance mandates or EU-facing procurement policies. Specify with confidence in government, healthcare, and international enterprise builds.
  • UL-listed fiber optic cable management assembly (to 2024A): The UL certification covers the FiberRunner cable management assemblies through the 2024A revision — relevant when the Authority Having Jurisdiction (AHJ) or insurance underwriter requires listed pathway components. Many data center construction specs require UL-listed cable management; this cover is part of that listed assembly.
  • Telcordia GR-63-CORE / NEBS Level 3 compliant: NEBS Level 3 is the standard required for equipment installed in carrier central offices and telco exchange environments. If your project is a carrier or colocation facility with NEBS-compliant infrastructure requirements, this cover meets the seismic, thermal, and mechanical stress criteria without an exception process.
  • Yellow color coding: Consistent with Panduit's FiberRunner color identification system. In mixed-pathway environments — where power, copper, and fiber runs share overhead infrastructure — color-coded covers accelerate identification during troubleshooting and reduce mis-routing during MAC work.

Integration & Compatibility

The FRFWCSC12LYL is designed exclusively for the Panduit FiberRunner 12x4 system. It does not fit FiberRunner 4x4, 6x4, or other channel-width variants — confirm the runway size before ordering. The cover snaps onto the 4-way cross fitting in the FiberRunner 12x4 family; no tools or hardware are required for installation or removal, which is consistent with the split cover's purpose as a serviceable, reusable component rather than a one-time-install piece.

Sold individually (package quantity: 1), with carton quantity of 5 units. For projects with multiple cross fitting locations — typical in structured cabling backbone runs across a data center floor — ordering by the carton reduces per-unit cost and ensures color consistency across the installation.

What's in the Box

  • 1x Panduit FRFWCSC12LYL FiberRunner 4-Way Cross Split Cover (Yellow)

Frequently Asked Questions

Q: What raceway system is the FRFWCSC12LYL compatible with?

A: The FRFWCSC12LYL is designed specifically for the Panduit FiberRunner 12x4 system. It fits the 4-way cross fitting for that channel size only. It is not interchangeable with FiberRunner 4x4 or 6x4 variants.

Q: Why is the FRFWCSC12LYL yellow?

A: Yellow is Panduit's color designation for this FiberRunner product family. In data centers and telecom facilities running multiple pathway types, color coding speeds up identification of fiber routes during maintenance, moves, adds, and changes.

Q: Does the FRFWCSC12LYL require tools to install or remove?

A: No. The split cover design snaps onto the 4-way cross fitting without tools, and the split sections open independently for cable access. This makes it a serviceable, reusable component suitable for live-facility MAC work.

Q: Is the FRFWCSC12LYL suitable for carrier central office installations?

A: Yes. The FRFWCSC12LYL is compliant with Telcordia GR-63-CORE and NEBS Level 3 standards — the baseline seismic and environmental requirements for carrier and central office infrastructure. It also meets RoHS and is part of a UL-listed cable management assembly (to 2024A).

Q: How many covers come in a package?

A: Package quantity is 1 unit. Carton quantity is 5 units. For larger deployments with multiple cross fitting locations, ordering by the carton ensures consistent color and reduces per-unit cost.

Q: What is the FRFWCSC12LYL made of?

A: The cover is constructed from a polycarbonate/ABS blend, which combines impact resistance with dimensional stability. This material holds up to incidental contact from cable pulls and equipment in busy data center environments without cracking or discoloring under typical lighting conditions.

Eden Phillips
Eden Phillips

The FRFWCSC12LYL is the component most facilities managers overlook until the first MAC event. At 22.25 inches long and built specifically for the FiberRunner 12x4 4-way cross, it's not interchangeable with other channel sizes — and the split design is the only reason a technician can break into one leg of a live cross fitting without disturbing three other active fiber runs. That's the spec that actually matters in a colocation row or carrier central office.

Technical Highlights:

  • Polycarbonate/ABS construction: More impact-tolerant than straight polycarbonate, and dimensionally stable under data center lighting — won't yellow or become brittle at the surface contact points where patch cords rest on the cover.
  • NEBS Level 3 / Telcordia GR-63-CORE compliance: Carrier and telco central office specs routinely mandate NEBS Level 3 for pathway components. This cover satisfies that requirement as part of the listed FiberRunner assembly — no exception documentation needed.
  • UL-listed to 2024A: The UL listing covers the cable management assembly through the current revision. In AHJ-reviewed projects where the inspector checks pathway listings, specifying the full FiberRunner system with matching listed covers avoids field rejections.

Deployment Considerations:

  • Verify your FiberRunner channel width before ordering — the FRFWCSC12LYL is dimensioned for 12x4 only. Installing a 12x4 cover on a 6x4 or 4x4 cross fitting won't seat correctly, and ordering the wrong cover on a large structured cabling project creates unnecessary rework.
  • Yellow color is fixed — if your facility uses a different color convention for fiber (e.g., aqua for single-mode, orange for multimode), coordinate with the project specification before committing to a full carton of 5 units per location.

The FRFWCSC12LYL is the right call for Tier III and Tier IV data center builds and carrier central offices where the FiberRunner 12x4 system is already specified and NEBS Level 3 compliance is a contract requirement — it closes the pathway properly, supports live-facility serviceability, and keeps the UL listing intact on the full assembly.

Specifications
Sub Brand: FiberRunner™
Application: Data centers et bureaux de télécommunication centraux
Color: Jaune
Material: Polycarbonate/ABS
Height In: 2.88
Height Mm: 73.2
Product Type: Capot en croix 4 voies
Carton Qty: 5
Package Qty: 1
Standards: Conforme RoHS, assemblages de guidage de câble optique certifiés UL jusqu'à 2024A, conformes aux épreuves d'application des normes Telcordia GR-63-CORE et Network Equipment Building Systems niveau 3
Upc: 61305676902
Cable Category: wire-routing-management-protection
Q&A
Reviews
Have Questions?

Panduit Split Cover 4-WAY Cross 12IN X 4IN 300EA

$313.70
$203.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources