Image coming soon
Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit FY9WP77B005F095 48-Fiber Single-Mode Plenum Trunk Cable Assembly

The Panduit FY9WP77B005F095 is a factory-terminated, 48-fiber single-mode trunk cable assembly from the Panduit QuickNet HD Flex line — built for data center interconnects, telecom rooms, and entrance facilities where you need pre-tested fiber infrastructure that installs in minutes, not hours. At 95 feet (29 meters), this trunk spans typical inter-row and cross-aisle distances without mid-run splicing or field termination.

Overview

Pre-terminated fiber optic trunk cables like the FY9WP77B005F095 exist to eliminate field termination risk. Every connector is factory-polished and tested before shipment — insertion loss is controlled, repeatability is documented, and you skip the labor and rework cost of field-terminating 48 fibers on a ladder above a live cabinet. For data center buildouts on a schedule, this approach pays off immediately.

The red jacket is a deliberate design choice: red is the TIA-568 color designation for single-mode fiber, so your team immediately identifies fiber type during installations, moves, and troubleshooting without pulling the cable spec sheet.

Key Features

  • 48-Fiber Single-Mode Construction: Single-mode fiber carries signal over much longer distances than multimode with lower loss — the right choice when linking equipment rooms across a large campus or connecting a colocation cage to a distribution frame. 48 fibers in a single trunk replaces a bundle of smaller assemblies, reducing pathway congestion and bend-radius violations.
  • ST Connectors: ST (bayonet-style) connectors are physically robust and lock in place with a quarter-turn, resisting accidental disconnection in high-density panels. If your patch panels or equipment already use ST ports, this trunk mates directly — no adapter coupling loss to worry about.
  • Plenum (OFNP) Flammability Rating: OFNP-rated jacket meets the NEC requirements for air-handling spaces — ceiling plenums, raised floors used as return-air paths, and HVAC ducts. Installing a non-plenum cable in a plenum space is a code violation and a fire risk. This cable eliminates that concern without requiring conduit in applicable spaces.
  • 95ft / 29m Length: Sized for inter-row runs, equipment room cross-connects, and entrance facility home runs where 50ft falls short but 100ft creates excessive slack management. The pulling-eye end (Polarity B strand identification) is designed for conduit pulls — thread it through a raceway without damaging connectors.
  • Polarity B / Stranded Pulling Eye End: The assembly ships with a stranded pulling eye on one end for conduit routing. Polarity B designation tells you exactly how to orient this trunk in a structured cabling system — critical when you're cascading trunks and modules and need to maintain consistent transmit/receive polarity end-to-end.
  • QuickNet HD Flex Sub-Brand: The HD Flex designation indicates a small-diameter construction optimized for high-density pathways — more cables fit in the same cable tray or conduit compared to standard-diameter trunk assemblies, which matters when you're retrofitting additional capacity into a facility without re-running all pathways.
  • Red Jacket Color: Red jacket aligns with TIA-568 single-mode color coding, enabling fast visual identification during installations, audits, and incident response without secondary labels.

Integration & Compatibility

This trunk is designed to integrate with Panduit QuickNet HD Flex patch panels and modules in standard structured cabling architectures. ST connectors are widely supported across legacy and current telecom equipment, data center switches, and optical transport gear. Verify your panels accept ST-terminated trunks — some high-density HD Flex enclosures are keyed for MPO/MTP connectors and require adapter modules to accept ST trunk tails.

Frequently Asked Questions

Q: What is the fiber count and mode type of the FY9WP77B005F095?

A: The FY9WP77B005F095 is a 48-fiber single-mode trunk cable assembly, designed for long-distance, low-loss interconnects in data centers and telecom rooms.

Q: Can this trunk cable be installed in a plenum ceiling or air-handling space?

A: Yes. The FY9WP77B005F095 carries a Plenum (OFNP) flammability rating, meeting NEC requirements for installation in air-handling plenum spaces without conduit where code permits.

Q: What connector type does the FY9WP77B005F095 use?

A: ST connectors — a bayonet-style connector that locks with a quarter-turn. Verify your patch panels and equipment ports accept ST before ordering.

Q: What does the Polarity B designation mean for installation?

A: Polarity B defines the fiber-to-connector mapping at each end. When cascading trunks and cassette modules in a structured cabling system, matching polarity types end-to-end is required to keep transmit and receive paths correct. Consult the Panduit QuickNet polarity guide to confirm Polarity B aligns with your system design.

Q: What is the pulling eye end used for?

A: The stranded pulling eye on one end allows the trunk to be pulled through conduit or innerduct during installation without stressing or damaging the pre-terminated connectors. Always pull from the pulling-eye end into the conduit.

Marty Allison
Marty Allison

The FY9WP77B005F095 is the assembly I spec when a data center buildout needs fiber installed fast and inspected later — not the other way around. The 48-fiber single-mode ST-terminated trunk at 95ft hits the sweet spot for inter-row runs where shorter assemblies leave you splicing and longer ones create unmanageable slack loops in cable trays.

Technical Highlights:

  • OFNP Plenum Rating: Eliminates the conduit requirement in air-handling ceiling spaces, saving significant installation labor on large floor plates. This is a code-compliance item, not a preference — skip it in a plenum space and you're writing an RFI to the AHJ.
  • 48-Fiber Count in Single Trunk: Consolidates what would otherwise be multiple smaller assemblies into one pathway-efficient run. In high-density cabinets, that pathway space is the constraint, not the fiber count.
  • ST Connector with Bayonet Lock: More vibration-resistant than LC push-pull in environments with frequent access. The quarter-turn lock gives tactile confirmation of seating — relevant when you're connecting in tight overhead trays without a clear sightline.

Deployment Considerations:

  • Confirm Polarity B is correct for your cassette/module scheme before ordering. Swapping polarity mid-run in a structured cabling system requires either re-ordering or adding polarity-flip modules, both of which add cost and delay.
  • ST is a legacy connector type — widely supported but being phased out in new high-density designs in favor of LC or MPO. Verify your panel inventory before committing to ST-terminated trunks at scale.

This trunk is the right specification for retrofitting single-mode capacity into an existing telecom room or entrance facility where ST-based panels are already in place and the 95ft span matches your inter-frame distance — not a greenfield MPO deployment.

Specifications
Cable Category: fiber_optic
Application: Data centers, telecommunications rooms, entrance facilities, and equipment distribution areas requiring pre-terminated fiber infrastructure for rapid deployment.
Color: Red
Connector Type: ST
Flammability Rating: Plenum (OFNP)
Length Ft: 95.0
Length M: 29.0
Product Type: Trunk Cable Assembly
Sub Brand: QuickNet™ HD Flex
Q&A
Reviews

Panduit 48-F Single-Mode Fiber Trunk - FY9WP77B005F095

$3,303.24
$2,139.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources