Image coming soon
Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit FY9WP77B005F059 48-Fiber Singlemode Plenum Trunk Cable Assembly

Overview

The Panduit FY9WP77B005F059 is a factory-terminated 48-fiber singlemode trunk cable assembly from the QuickNet™ HD Flex sub-brand, built for structured cabling deployments where speed of installation and code compliance matter equally. At 59 feet (18 meters), this pre-terminated assembly bridges backbone runs in fiber optic trunk cable applications — data centers, telecommunications rooms, entrance facilities, and equipment distribution areas — without any field termination required. The red outer jacket aids instant visual identification in densely cabled environments, and the plenum (OFNP) rating means it can run through air-handling spaces without triggering building code violations.

For integrators pulling infrastructure in occupied facilities, the value of a factory-terminated trunk is straightforward: no fusion splicer on-site, no termination quality variability, and no waiting on connector polish. The assembly ships ready to install, with a stranded pulling eye end that protects the connectors during the pull itself — a detail that matters when you're threading 48 fibers through conduit without abrading the ferrules before the cable even reaches the rack.

Key Features

  • 48-Fiber Count, Singlemode: Singlemode fiber supports distances and bandwidth levels that multimode cannot approach — if your backbone spans more than a few hundred meters or needs to accommodate future high-speed DWDM upgrades, singlemode is the correct choice. 48 fibers in one trunk consolidates what would otherwise require multiple smaller assemblies, reducing pathway congestion and simplifying documentation.
  • 59-Foot (18-Meter) Pre-Terminated Length: Factory termination eliminates field splicing entirely. A 59-foot run covers typical inter-rack and row-to-row distances in mid-size data halls, or the span from a telecom room to a nearby IDF — without coiling excess cable that eats up rack U-space or pathway capacity.
  • Plenum (OFNP) Flammability Rating: OFNP-rated jacketing meets the low-smoke, low-flame requirements for installation in air-handling plenums and return-air spaces. Where local fire codes require plenum-rated cable in ceiling voids or raised-floor environments, this assembly qualifies without requiring a conduit sleeve workaround. Running riser-rated cable in a plenum space is a code violation — this assembly eliminates that risk.
  • ST Connector Type: ST connectors are a bayonet-latch design long established in legacy telecommunications and campus backbone infrastructure. If you're extending or interconnecting with an installed base that uses ST terminations — common in older enterprise campuses and some government facilities — this assembly interfaces directly without adapter panels. Verify your patch panel and equipment ports before ordering if your infrastructure uses LC or SC terminations instead.
  • Red Cable Jacket: Color coding is a real operational tool in dense fiber environments. Red typically designates singlemode fiber in many data center color conventions, making it visually distinct from multimode assemblies (often orange or aqua) during troubleshooting, moves-adds-changes, and audits. Consistent color discipline reduces mis-patching incidents.
  • Stranded Pulling Eye End: The pulling eye end is engineered to take the mechanical load during installation without transferring stress to the connectors. This protects ferrule alignment and endface cleanliness before the cable is ever plugged in — a common source of insertion loss problems when pulling pre-terminated assemblies without this feature.
  • QuickNet™ HD Flex Sub-Brand: The HD Flex designation within the Panduit structured cabling line indicates a high-density, flexible-routing design philosophy — meaning the cable bend radius and jacket construction are optimized for tight pathways and overhead cable management typical in modern data centers, not just open-trench legacy runs.

Integration & Compatibility

The FY9WP77B005F059 is designed for integration with compatible fiber patch panels and QuickNet-series connectivity modules that accept ST-terminated trunks. Before deploying, confirm that your termination panels support ST connectors on the trunk-side port — panels configured for MPO/MTP or LC-duplex trunks are not compatible without adapter modules. This assembly targets environments already standardized on ST backbone terminations; greenfield deployments using modern high-density LC or MPO infrastructure should evaluate the appropriate connector family instead.

For data center deployments, pair this trunk with compatible fiber distribution frames or cassette-based patch panels to maintain the pre-terminated system's speed advantage. The plenum rating makes it compatible with installations in air-handling ceiling spaces in commercial buildings — a common requirement in enterprise campus and healthcare environments where cable routing through mechanical spaces is unavoidable.

If your project involves longer backbone runs or higher fiber counts, evaluate other assemblies in the Panduit QuickNet portfolio — length and fiber-count variants are available to match specific infrastructure designs without field customization.

Frequently Asked Questions

Q: What connector type does the FY9WP77B005F059 use?

A: The FY9WP77B005F059 uses ST connectors. ST is a bayonet-latch style common in legacy enterprise campus and telecommunications backbone infrastructure. If your patch panels or equipment use LC, SC, or MPO terminations, this assembly is not directly compatible without adapter panels.

Q: Is the FY9WP77B005F059 rated for installation in plenum/air-handling spaces?

A: Yes. The FY9WP77B005F059 carries a Plenum (OFNP) flammability rating, which qualifies it for installation in air-handling plenums and return-air spaces under NEC and most local fire codes. Riser-rated cable cannot be substituted in plenum spaces — this assembly meets that requirement directly.

Q: What is the fiber type — singlemode or multimode?

A: Singlemode. Singlemode fiber supports substantially longer transmission distances and higher bandwidth than multimode, making it the correct choice for backbone runs that span more than a few hundred meters or where future high-capacity wavelength-division multiplexing is anticipated.

Q: What does the 59-foot length correspond to in meters?

A: The FY9WP77B005F059 is 59 feet, which is 18 meters. This length is suited for inter-rack, row-to-row, and short-run telecommunications room to IDF distances without requiring field splicing or excess cable management.

Q: What is the significance of the red jacket color?

A: Red is a common color convention designating singlemode fiber in data center and structured cabling environments, helping technicians visually distinguish singlemode assemblies from multimode (typically orange or aqua) during installation, troubleshooting, and MACs. It is a real operational tool in dense cable environments, not purely aesthetic.

Q: Does the FY9WP77B005F059 require field termination?

A: No. It is a factory pre-terminated trunk cable assembly. Both ends are terminated at the factory under controlled conditions, eliminating the need for on-site splicing, polishing, or termination equipment. The stranded pulling eye end protects the connectors during conduit pulls.

Karl Wilson
Karl Wilson

The detail I keep coming back to on the FY9WP77B005F059 is the stranded pulling eye end — it's a small engineering choice that has a real impact in practice. When you're threading 48 singlemode fibers through conduit or overhead cable management, transferring pull tension through the eye rather than the connectors keeps the ferrule endfaces clean and undamaged before the assembly is ever plugged in. Field-terminated installations don't get that guarantee. This is the assembly I'd spec where the labor cost of a re-termination or a polishing mistake on-site is genuinely painful.

Technical Highlights:

  • 48-Fiber Singlemode Count: Consolidating 48 fibers into a single factory-terminated trunk eliminates multiple smaller assemblies, reduces pathway congestion, and cuts documentation complexity — each of which compounds as infrastructure scales.
  • Plenum (OFNP) Rating: OFNP compliance is not optional where cable routes through air-handling spaces — it's a code requirement. This assembly satisfies it without conduit sleeves or route redesign, which directly affects installation schedule and cost.
  • 59-Foot (18-Meter) Pre-Terminated Length: The 18-meter run length maps cleanly to typical inter-row and telecom-room-to-IDF distances in mid-size enterprise data halls. No field splicing means the installation schedule is not dependent on a termination technician's availability or skill level.

Deployment Considerations:

  • ST connectors are correct for facilities standardized on ST backbone terminations — common in older campus and government infrastructure. Greenfield data center builds using modern high-density LC or MPO infrastructure should specify the correct connector family from the QuickNet portfolio instead; adapters add insertion loss and a failure point.
  • Confirm your patch panels accept ST-terminated trunks on the trunk-side port before ordering. Panels configured for MPO/MTP or LC-duplex trunks will not accept this assembly without adapter modules, which defeats the speed-of-deployment advantage of a pre-terminated system.

The FY9WP77B005F059 is the right specification for enterprise campus backbone extensions and telecommunications room consolidation projects where the installed base is ST-terminated, the route passes through plenum-rated spaces, and the project timeline does not accommodate field termination delays.

Specifications
Cable Category: fiber_optic
Application: Data centers, telecommunications rooms, entrance facilities, and equipment distribution areas requiring pre-terminated fiber infrastructure for rapid deployment.
Color: Red
Connector Type: ST
Flammability Rating: Plenum (OFNP)
Length Ft: 59.0
Length M: 18.0
Product Type: Trunk Cable Assembly
Sub Brand: QuickNet™ HD Flex
Q&A
Reviews

Panduit 48-F Single-Mode Fiber Trunk - FY9WP77B005F059

$3,080.04
$1,810.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources