Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit FY9WP77B005F094 48-Fiber Singlemode Plenum Trunk Cable Assembly

Overview

The Panduit FY9WP77B005F094 is a factory-terminated, 48-fiber singlemode indoor trunk cable assembly from the Panduit QuickNet HD Flex line — purpose-built for data centers, telecommunications rooms, entrance facilities, and equipment distribution areas that need to bring up fiber optic infrastructure fast without field termination. At 94 feet (28.6 meters), this assembly bridges the inter-rack and inter-room distances common in mid-to-large enterprise and colocation facilities, and its plenum-rated jacket means it can run through air-handling spaces without triggering code compliance issues.

The red jacket on the FY9WP77B005F094 follows the industry color convention for singlemode fiber, giving installers and operations teams an immediate visual cue at the cable tray or patch panel — no guessing whether you're looking at multimode or singlemode infrastructure during a maintenance event or hot cutover.

Key Features

  • 48-Fiber Singlemode Core: Forty-eight fibers in a single trunk means you can provision a full rack's worth of 100G or 400G connections — or a mix of 40G and 10G — from a single cable pull. That density matters in spine-leaf architectures where every inter-switch link occupies a fiber pair, and you need headroom for future growth without re-pulling cable.
  • 94-Foot (28.6m) Pre-Terminated Length: Factory termination eliminates field splicing, which is the single largest source of insertion loss variance in a fiber plant. You get a tested, consistent assembly — run it from the MDA to the HDA, plug in, and you're done. The 94-foot length accommodates typical inter-row or cross-aisle runs in medium to large data halls without leaving excessive slack coiled in the tray.
  • Plenum (OFNP) Flammability Rating: Plenum-rated cable can be installed in air-handling spaces — above drop ceilings, in raised floors used as air return plenums, and in HVAC ducts — without requiring conduit. This directly reduces installation labor and material cost in plenum-return environments, and it satisfies NEC Article 770 requirements for those spaces without a variance or conduit workaround.
  • ST Connector Termination: ST connectors are a bayonet-style, round ferrule connector common in older and mid-tier enterprise infrastructure, telecommunications rooms, and campus backbones. If your patch panels, media converters, or legacy switches use ST ports, this assembly mates directly — no adapter sleeves required, which each add 0.5–1.0 dB of insertion loss and a potential failure point.
  • QuickNet HD Flex Sub-Brand: The QuickNet HD Flex platform is engineered for small-diameter, high-density routing — the trunk routes through congested cable trays and around tight bend radii more easily than standard-diameter trunks. In dense data centers where tray fill ratios are already high, the reduced OD translates to real installation flexibility and better airflow around cable pathways.
  • Red Jacket Color Coding: Per TIA-598-C, red identifies singlemode fiber assemblies. In mixed-fiber environments — where both OS2 singlemode and OM3/OM4 multimode trunks run in the same tray — color coding is the fastest audit tool you have. Red on this assembly means any technician can confirm fiber type at a glance, reducing mis-patch risk during moves, adds, and changes.
  • Polarity Type B Configuration: The Polarity B (PLRTYB) configuration maps fiber positions in a defined pattern at each end. Before installing, verify your fiber optic patch panel and transceiver polarity scheme match Type B — mismatched polarity is a common commissioning delay that a pre-pull check eliminates entirely.
  • Strain-Relief Pulling Eye End A: The factory-installed pulling eye on End A allows the cable to be pulled through conduit or cable tray runs using standard pull tape or pull string without stressing the terminations. This is a detail that matters on longer runs through conduit — pulling force applied directly to the connector body or jacket risks damaging the factory-set terminations before the cable is even installed.

Integration and Compatibility

This assembly is designed for structured cabling environments following TIA-568 and ISO/IEC 11801 standards. The ST connector format is compatible with legacy patch panels, media converters, switches, and active equipment using ST-type fiber ports. For environments transitioning from ST to LC infrastructure, ST-to-LC duplex adapters are available to bridge the two connector ecosystems — though each adapter pair adds insertion loss that should be budgeted in your optical link budget calculation.

The OFNP plenum rating satisfies NEC 770.179 requirements for installation in plenum air-handling spaces. The singlemode fiber type is compatible with 1310nm and 1550nm wavelength transceivers used in 1G, 10G, 40G, and 100G applications depending on the transceiver specification. Pair this trunk with compatible fiber patch panels and ST-port patch cords to complete the structured cabling link from active equipment to the trunk backbone. For the active equipment side, verify your network switch or media converter SFP/SFP+ transceiver wavelength and reach specification matches an OS2 singlemode fiber plant.

Frequently Asked Questions

Q: What polarity type does the FY9WP77B005F094 use, and how do I confirm compatibility with my patch panels?

A: This assembly uses Polarity Type B (PLRTYB). Before installation, verify that your patch panels and transceivers are also configured for Type B polarity. Mismatched polarity between the trunk and the panels is a common commissioning issue — check your panel documentation or contact the panel manufacturer to confirm the polarity scheme before pulling the cable.

Q: Can the FY9WP77B005F094 be installed in a plenum air-handling ceiling space without conduit?

A: Yes. The OFNP (Optical Fiber Nonconductive Plenum) flammability rating satisfies NEC Article 770 requirements for installation in plenum air-handling spaces, including above drop ceilings used as air return plenums and in raised floors with HVAC airflow. Conduit is not required in these spaces when using OFNP-rated cable.

Q: What wavelengths and data rates is the singlemode fiber in this trunk compatible with?

A: Singlemode (OS2) fiber supports 1310nm and 1550nm wavelength transceivers and is compatible with 1G, 10G, 40G, 100G, and beyond — depending on the transceiver specification. Confirm that your active equipment transceivers are rated for singlemode fiber and the appropriate wavelength before deploying.

Q: What is the purpose of the pulling eye on End A?

A: The factory-installed strain-relief pulling eye on End A allows the cable to be pulled through conduit or cable tray runs using pull tape or pull string without applying tension directly to the terminations or jacket. This protects the factory-set fiber terminations during installation, which is especially important on longer conduit runs where significant pull force may be required.

Q: Are ST connectors compatible with LC patch panels?

A: ST and LC are different connector formats and are not directly intermateable. ST-to-LC hybrid adapter sleeves or couplers are available to bridge the two, but each adapter pair adds insertion loss (typically 0.5–1.0 dB) that must be included in your optical link budget. If your panels use LC connectors, evaluate whether ST-to-LC adapters fit within your loss budget or whether LC-terminated trunks are a better fit for your infrastructure.

Q: Is the FY9WP77B005F094 suitable for outdoor installation?

A: No. This is an indoor-rated assembly with a plenum jacket. It is not rated for outdoor, direct burial, or OSP (outside plant) use. For outdoor runs, a separate OSP-rated or armored fiber trunk designed for outdoor environments is required.

Ted Perry
Ted Perry

The FY9WP77B005F094 is a 94-foot, 48-fiber singlemode plenum trunk — exactly the kind of pre-terminated assembly that makes the difference between a two-day fiber commissioning event and a four-hour one. The 48-fiber count is the spec I'd focus on first: in a spine-leaf deployment, you're burning two fibers per 100G BiDi link, which means this single trunk can feed 24 active connections between two devices. That's a full 48-port switch face in a single pull.

Technical Highlights:

  • OFNP Plenum Rating: Eliminates conduit in air-handling spaces — the labor delta between a conduit run and a direct cable pull in a 94-foot span can be several hours of labor cost per run. If you have six trunks to pull across a plenum ceiling, that math adds up quickly.
  • Factory Termination with Pulling Eye: The strain-relief pulling eye on End A is not a minor detail. On a 48-fiber singlemode assembly, a single cracked ferrule from a bad pull costs more in re-termination time than the cable itself. The pulling eye isolates pull tension from the terminations where it belongs.
  • Polarity Type B: Polarity B gives you a straight-through mapping that works cleanly with most standard patch panel and transceiver configurations. Document which polarity standard your site uses before ordering multiple trunks — mixing polarity types across a structured cabling plant is the kind of problem that surfaces at 2am during a cutover.

Deployment Considerations:

  • ST connectors are a legacy format relative to LC. If your environment is LC-standardized, run the optical link budget with ST-to-LC adapter loss included before committing to ST trunks — you may be better served by an LC-terminated variant in the same QuickNet HD Flex family.
  • The 94-foot length is fixed — factory trunks are not field-shortenable without re-termination. Measure your actual run length including tray routing (not just point-to-point distance) before ordering; add 10–15% for routing overhead before confirming the length is adequate.

This trunk is the right call for a telecommunications room or data center MDA-to-HDA run where you need singlemode capacity, plenum compliance, and a fiber count high enough to support full-rack dense optical interconnects without a secondary cable pull.

Specifications
Cable Category: fiber_optic
Application: Data centers, telecommunications rooms, entrance facilities, and equipment distribution areas requiring pre-terminated fiber infrastructure for rapid deployment.
Color: Red
Connector Type: ST
Flammability Rating: Plenum (OFNP)
Length Ft: 94.0
Length M: 28.6
Product Type: Trunk Cable Assembly
Sub Brand: QuickNet™ HD Flex
Q&A
Reviews

Panduit 48-F Indoor SM Trunk - FY9WP77B005F094

$3,297.04
$1,938.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources