Image coming soon
Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit FY9WP77B005F054 48-Fiber Singlemode Plenum Trunk Cable Assembly

The Panduit FY9WP77B005F054 is a factory-terminated, 48-fiber singlemode trunk cable assembly from the Panduit QuickNet HD Flex line — built for data center structured cabling environments where installation speed and long-term optical performance are both non-negotiable. At 54 feet (16.5 meters), this assembly bridges equipment distribution areas and telecom rooms without the labor overhead of field termination. ST connectors on both ends, a plenum-rated OFNP jacket, and a distinctive red outer sheath make it straightforward to install and identify in dense cable trays.

Overview

Pre-terminated fiber optic trunk cable assemblies like the FY9WP77B005F054 exist to eliminate one of the most time-intensive steps in structured cabling: on-site connector termination. In a data center rollout or a telecommunications room build-out, the difference between pulling pre-tested factory assemblies and field-terminating 48 fibers is measured in hours — sometimes days. Panduit's QuickNet HD Flex platform targets exactly that use case: entrance facilities, equipment distribution areas, and horizontal cross-connect runs where uptime pressure makes field termination a liability rather than a cost savings.

Key Features

  • 48-Fiber Singlemode Core: Singlemode fiber supports longer reach and higher bandwidth density than multimode — the right foundation for inter-building runs, long horizontal distances, and 10G/40G/100G wavelength-division multiplexing applications where modal dispersion would otherwise be a ceiling.
  • 54-Foot (16.5m) Factory Length: The 54 ft run covers typical equipment-room-to-distribution-area spans without requiring a splice or a field-cut. Ordering by exact length eliminates the coiled slack problem that complicates airflow in hot-aisle/cold-aisle deployments.
  • ST Connectors, Both Ends: ST (straight tip) bayonet-style connectors are still common in legacy data center and telecom infrastructure. This assembly integrates directly into existing ST-based patch panels and equipment ports — no adapter sleeves required when your installed base uses ST.
  • Plenum (OFNP) Flammability Rating: OFNP-rated jacket means this cable is code-compliant for installation inside air-handling plenum spaces without conduit. That removes a significant cost line — metal conduit in plenum ceilings and raised floors adds both material and labor. If your run passes through a plenum return-air space, this rating is mandatory, not optional.
  • Red Jacket Color: The red outer sheath is a visual identifier in the cable tray. Industry convention commonly associates red with singlemode fiber or specific zone designations. In a mixed-fiber environment with multiple trunk types, color-coded assemblies reduce mis-patching risk during moves, adds, and changes.
  • Stranded Pulling Eye End (End A): The pulling-eye construction on End A is engineered for conduit pulls and J-hook runs. A purpose-built pulling eye distributes tensile load across the cable structure rather than concentrating it at the connector ferrules — protecting factory-set insertion loss values through the pull.
  • QuickNet HD Flex Sub-Brand: The HD Flex designation signals high-density, flexible-routing construction — relevant when routing through congested pathways, tight bend radii around cable managers, or overhead trays where a rigid assembly would kink.

Integration & Compatibility

The FY9WP77B005F054 is designed for structured cabling infrastructure in data centers, telecommunications rooms, entrance facilities, and equipment distribution areas. ST connectors mate directly with ST-port patch panels and active equipment. For environments standardized on LC or SC ports, ST-to-LC or ST-to-SC adapter panels are a common bridge — verify your panel port type before ordering. Singlemode fiber is compatible with singlemode-rated transceivers and SFP modules; do not pair with multimode-only optics. The OFNP jacket satisfies NEC Article 770 plenum requirements, making this assembly usable in both plenum and non-plenum pathways.

If your project involves high-density fiber distribution at the zone or floor level, pair this trunk with compatible fiber patch panels to complete the pre-terminated zone distribution architecture.

Frequently Asked Questions

Q: Is the FY9WP77B005F054 rated for plenum air-handling spaces?

A: Yes. The FY9WP77B005F054 carries a Plenum (OFNP) flammability rating, making it code-compliant for installation in air-handling plenum spaces per NEC Article 770 without requiring metal conduit.

Q: What connector type is on both ends of this trunk assembly?

A: Both ends use ST (straight tip) connectors. ST is a bayonet-style connector common in legacy data center and telecom infrastructure. If your patch panels use LC or SC ports, you will need adapter panels to bridge the connection.

Q: Can this cable be used with multimode transceivers?

A: No. This is a singlemode fiber assembly and must be paired with singlemode-rated transceivers and optics. Pairing with multimode-only SFPs will result in signal loss and unreliable links.

Q: What does the pulling-eye construction on End A mean for installation?

A: The stranded pulling eye on End A allows the cable to be pulled through conduit or cable pathways with tensile load distributed across the cable structure rather than the connector ferrules — preserving factory insertion loss performance after the pull.

Q: Why is the jacket red on this trunk assembly?

A: The red jacket is a visual identifier used for cable management and zone designation in the tray. In mixed-fiber environments, color-coded trunks reduce mis-patching risk during moves, adds, and changes.

Q: What is the exact length of the FY9WP77B005F054?

A: The assembly is 54 feet (16.5 meters) in overall length, factory-terminated — no field cutting or splicing required.

James Everett
James Everett

The FY9WP77B005F054 is one of those assemblies that earns its price tag in labor savings alone. A 48-fiber factory-terminated singlemode trunk with a purpose-built pulling eye — tested before it leaves the factory — eliminates the risk of a bad field termination on fiber 31 of 48 that you don't find until commissioning. In my experience, that's where pre-terminated assemblies justify themselves in data center builds: not the cable cost, but the technician time and re-work avoidance.

Technical Highlights:

  • 48-Fiber Count: Forty-eight singlemode fibers in a single trunk supports zone distribution architectures where a single pull services an entire equipment bay — compare that to running multiple smaller-count trunks and the conduit fill math changes significantly.
  • OFNP Plenum Rating: NEC-compliant for open plenum installation means no conduit budget line in plenum ceiling or raised floor pathways — on a 54-foot run that can eliminate 10–15 feet of metal conduit and associated fittings per drop.
  • 16.5-Meter Factory Length: The 54 ft / 16.5 m length is a common horizontal span in equipment distribution areas. Ordering to exact length keeps the assembly taut and managed — no coiled slack sitting on top of a cable manager and blocking airflow.

Deployment Considerations:

  • Verify your patch panel port type before ordering — ST connectors are correct for ST-based panels, but if your target panels are LC-port QuickNet or comparable, you need either an ST-LC adapter panel or a different trunk variant. Ordering the wrong connector family means a full return, not a field fix.
  • ST connectors are a bayonet-lock style: they require a quarter-turn to seat and lock. In high-density trays where access is tight, confirm your panel mounting depth gives enough clearance for the ST twist — some ultra-high-density panels make ST access awkward compared to push-pull LC.

This assembly is the right call for a structured cabling refresh or greenfield data center build where the installed base or target infrastructure is already ST-terminated — entrance facility cross-connects and older telecom room panels in particular. For a net-new deployment standardizing on LC-density panels, evaluate whether a LC-connector variant in the same QuickNet HD Flex family better matches your long-term port roadmap.

Specifications
Cable Category: fiber_optic
Application: Data centers, telecommunications rooms, entrance facilities, and equipment distribution areas requiring pre-terminated fiber infrastructure for rapid deployment.
Color: Red
Connector Type: ST
Flammability Rating: Plenum (OFNP)
Length Ft: 54.0
Length M: 16.5
Product Type: Trunk Cable Assembly
Sub Brand: QuickNet™ HD Flex
Q&A
Reviews

Panduit 48-F Indoor Trunk - FY9WP77B005F054

$3,049.04
$1,974.99

RELATED PRODUCTS

Save $1,371.83
Panduit FYZWP88Y005F019 OM4 48-F Indoor Trunk Cable
Add to Cart The item has been added

Panduit FYZWP88Y005F019

Panduit FYZWP88Y005F019 OM4 48-F Indoor Trunk Cable

19-foot OM4 48-fiber indoor trunk cable assembly designed for high-density, rapid deployment in data centers, telecommunications rooms, and entrance

    Usually Ships in 2-3 Weeks Free shipping over $499
    $3,329.82 $1,957.99 Save $1,371.83
    The item has been added Add to quote
    $3,329.82 $1,957.99 Save $1,371.83
    Save $1,371.83 Add to cart Add to quote

    System Design, Deployment & Technical Support

    Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

    Fixed scope • Fixed price

    System Design Assistance

    • Get help validating product compatibility
    • Coverage requirements
    • Storage planning and deployment architecture before you buy.
    Request Design Help

    Deployment & Configuration Support

    • Access fixed-scope support for rollout planning
    • User setup guidance
    • Migration and system standardization across single-site or multi-site deployments
    View Support Services

    Guides, Tools & Calculators

    • PoE requirements
    • Storage retention
    • Camera selection and deployment methodology
    Open Technical Resources