Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric SMX1500RM2UC 1440VA 2U Rack-Mount Line-Interactive UPS

Overview

The APC by Schneider Electric SMX1500RM2UC is a 1440VA / 1350W line-interactive UPS in a 2U rack-mount form factor, engineered for NVR closets, edge compute racks, and network infrastructure where a clean, uninterrupted 120V sine wave matters. It draws on a 48V lead-acid battery bank (288 VAh) to deliver 5 minutes at full load and 15 minutes at half load — enough runway to execute a controlled shutdown or ride out brief utility interruptions without losing recording continuity. The true sine wave output keeps sensitive switch-mode power supplies and active PFC loads stable, which matters when your rack holds IP surveillance recorders or PoE switches that don't tolerate modified wave from cheaper UPS units.

Line-interactive topology means the SMX1500RM2UC conditions voltage continuously without switching to battery for every minor fluctuation. The auto-sensing input accepts 75–154V, widening the range of acceptable utility power before the unit has to draw down the battery — an important consideration in buildings with aging electrical infrastructure or long panel-to-rack runs.

Key Features

  • 1440VA / 1350W True Sine Wave Output: Full sine wave at 120V protects active PFC power supplies in modern NVRs and servers from the waveform distortion that trips over-voltage protection circuits. At 1350W rated capacity, you have enough headroom to support a fully loaded 1U NVR, a managed PoE switch, and ancillary edge gear on a single circuit.
  • Line-Interactive with 75–154V Input Range: The broad input window absorbs sags and swells before battery is needed, extending battery life and reducing wear. 120V nominal input, 12A maximum — fits a standard 15A circuit. The 20A switching current capacity means the UPS handles inrush from simultaneous boot-up of multiple devices without tripping.
  • 5-Minute Full Load / 15-Minute Half Load Runtime: At 1350W you get 5 minutes — sufficient for a graceful NVR shutdown or a generator start sequence. At 675W (half load, typical for a mid-density IP camera rack) you get 15 minutes, buying real time to respond to an outage before storage corruption risk becomes a concern.
  • 8 NEMA 5-15R Outlets: Eight rear-panel outlets give you enough positions to cover an NVR, a PoE switch, a management workstation, and spare capacity for future expansion — all on a single 2U footprint. NEMA 5-15R matches standard 15A rack PDU and wall-outlet wiring in North American facilities.
  • 645J Surge Energy Rating with Full-Time Multi-Pole Noise Filtering: 645 joules of surge absorption, IEEE let-through at 5% of incoming surge energy, and multi-pole noise suppression (filtering all lines continuously, not just clamping at trigger) keep switching transients and EMI off the protected outlets. Zero clamping response time means there's no leading-edge spike before protection engages.
  • 48V / 288 VAh Battery with 3-Hour Recharge: The 288 VAh battery bank recharges in 3 hours from a full discharge — important when utility power is intermittent. Expected battery life is 3–5 years under normal operating conditions; plan replacement at year 3 in high-temperature environments to avoid capacity degradation at a critical moment.
  • 103W Battery Charger: The built-in 103W charger is sized to recharge without starving the UPS of capacity during partial-discharge recovery events. Not field-upgradeable — factor this charge rate into multi-outage shift planning.
  • 40 dBA Acoustic Level: Rated at 40 dBA, the SMX1500RM2UC runs quietly enough for IDF closets and open office server rooms where fan noise is a concern. Not silent, but comparable to a typical 1U switch at moderate load.
  • 0–40°C Operating Range: Rated for up to 40°C ambient — workable in most conditioned server rooms and locked IDF cabinets with adequate airflow, but not suitable for unconditioned attics or outdoor enclosures where temperatures routinely exceed this ceiling.
  • UL 1778 / CUL Listed: Meets UL 1778 (the standard for uninterruptible power systems) and carries CUL listing for Canadian deployments. These certifications are the minimum bar for commercial facility acceptance by AHJs and insurance underwriters.

Integration & Compatibility

The SMX1500RM2UC ships with a NEMA 5-15P input plug, compatible with standard 15A North American outlets. It occupies 2U of rack space with front-mount access, making it suitable for two-post and four-post open-frame racks as well as enclosed cabinets with adequate depth — the unit runs 49 cm (approximately 19.3 inches) deep, so confirm your cabinet's usable depth before ordering. The 43.2 cm width is standard 19-inch rack compatible.

For surveillance infrastructure deployments, pair this UPS with a managed PoE switch and a compatible network video recorder to build a protected recording node. The 8-outlet capacity typically covers: 1x NVR, 1x PoE switch, 1x management station, and 1–2 ancillary devices. If your NVR draws significantly more than 400W at steady state, calculate your load against the 1350W ceiling before finalizing the configuration.

Review the full power protection lineup if your load exceeds 1440VA or requires extended runtime — APC's SMX family includes higher-VA models in the same rack form factor. For parallel or 3-phase deployments, this single-phase 120V unit is out of scope.

The APC by Schneider Electric UPS and power protection catalog covers a broad range of load sizes and form factors for surveillance and IT infrastructure applications.

Frequently Asked Questions

Q: What is the full load runtime of the SMX1500RM2UC?

A: At full load (1350W), the SMX1500RM2UC provides approximately 5 minutes of runtime. At half load (675W), runtime extends to approximately 15 minutes. These figures are based on the 48V / 288 VAh battery bank.

Q: Does the SMX1500RM2UC output a true sine wave?

A: Yes. The SMX1500RM2UC produces a true sine wave output, which is required for active PFC power supplies found in many modern NVRs, servers, and managed switches. Modified sine wave units can trigger over-voltage faults in these devices.

Q: How many outlets does the SMX1500RM2UC have and what type are they?

A: It has 8 NEMA 5-15R outlets on the rear panel, all battery-backed. These are standard 15A North American receptacles compatible with typical rack and desktop equipment power cords.

Q: What is the input voltage range and plug type for the SMX1500RM2UC?

A: The input is 120V nominal with an adjustable range of 75–154V before switching to battery. The input plug is NEMA 5-15P, compatible with standard 15A North American circuits. Maximum input current is 12A.

Q: How long does the SMX1500RM2UC battery take to recharge?

A: The internal 103W charger fully recharges the battery in approximately 3 hours from a full discharge. Expected battery life under normal operating conditions is 3–5 years.

Q: What rack space does the SMX1500RM2UC require and how deep is it?

A: The SMX1500RM2UC occupies 2U of rack space, is 43.2 cm (17 in) wide for standard 19-inch rack compatibility, and is 49 cm (approximately 19.3 in) deep. Verify your cabinet's usable depth before installation.

Marty Allison
Marty Allison

The spec that defines where the SMX1500RM2UC earns its place is the 75–154V input range paired with true sine wave output — on a line-interactive topology, that combination means the unit is actively boosting or trimming voltage before load devices ever see a problem, and when it does go to battery, sensitive active-PFC gear like modern NVRs gets a clean waveform rather than the stepped approximation that cheaper units produce. I've seen that distinction matter specifically on Hikvision and Hanwha recorders with switching supplies that trip on modified wave during a transfer event.

Technical Highlights:

  • 288 VAh Battery Capacity: At 288 VAh on a 48V bank, you're getting meaningful energy storage for a 2U unit — 15 minutes at 675W is a realistic half-load scenario for a mid-density surveillance rack, and 3-hour recharge means you're back to full capacity well before the next maintenance window closes.
  • 645J Surge Rating + 5% IEEE Let-Through: 645 joules is solid for rack gear protection, and the 5% IEEE let-through spec tells you the clamping is tight — most of the surge energy is absorbed rather than passed downstream. Zero clamping response time eliminates the leading-edge spike window that lower-grade suppressors leave open.
  • 103W Onboard Charger: The 103W charger is sized to recover the battery without pulling heavily from the protected bus. That matters in facilities with frequent short outages — you're not running depleted into the next event because recovery is slow.

Deployment Considerations:

  • At 49 cm depth and 24.82 kg, confirm your rack cabinet's usable depth and rail load rating before mounting — two-post open-frame racks may need a shelf or rear support at this weight. The unit is front-mount access, so cable routing to the rear outlets requires planning in tight enclosed cabinets.
  • The 40°C operating ceiling is the real constraint in edge deployments: IDF closets with poor airflow or equipment rooms in warm climates can exceed this during summer peaks, accelerating battery aging toward the lower end of the 3–5 year window. Budget for battery replacement at year 3 in these environments.

This unit is the right fit for a surveillance IDF node running a mid-density NVR (under 800W steady state), a managed PoE switch, and ancillary gear — the 8-outlet layout and 1350W ceiling cover that load profile cleanly in 2U. It's not sized for high-density recording servers or parallel-redundant configurations; those need higher VA models in the SMX family.

Specifications
Cable Length: 2.44 m
Rack Unit: 2U
Color: Black
Depth: 49 cm
Height: 8.9 cm
Mounting Location: Front
Net Weight: 24.82 kg
Mounting Mode: Rack-mounted with kit
Width: 43.2 cm
Storage Temperature: -15…45 °C
Storage Altitude: 0.00…15240.00 m
Acoustic Level: 40 dBA
Heat Dissipation: 133 Btu/h
Battery Type: Lead-acid battery
Battery Recharge Time: 3 h
Battery Voltage: 48 V
Battery Charger Power: 103 W rated
Battery Power in VAH: 288 VAh
Battery Life: 3…5 year(s)
Surge Energy Rate: 645 J
Noise Suppression: Full time multi-pole noise filtering
IEEE Surge Let-through: 5%
Response Time: zero clamping
Standards: UL 1778
Package Weight: 30 kg
Package Height: 24.6 cm
Package Width: 58.9 cm
Package Length: 62 cm
Network Frequency: 50/60 Hz +/- 3 Hz auto-sensing
Plug Standard: NEMA 5-15P
Input Voltage Limits: 75...154 V adjustable
Maximum Input Current: 12 A
Switching Current Capacity: 20 A
Max Short Time Withstand Current: 1000 kA
Input Voltage: 120 V
Rated Power in W: 1350 W
Harmonic Distortion: Less than 5 %
Output Frequency: 50/60 Hz +/- 3 Hz sync to mains
UPS Type: Line interactive
Wave Type: Sine wave
Number of Power Socket Outlets: 8 NEMA 5-15R
Full Load Runtime: 00:05:00
Half Load Runtime: 00:15:00
Output Voltage: 120 V
Maximum Configurable Power in VA: 1440 VA
Rated Power in VA: 1440 VA
Product Certifications: CUL listed
Operating Temperature: 0…40 °C
Relative Humidity: 0…95 %
Operating Altitude: 0...10000 ft
freight: 186.60
Q&A
Reviews
Have Questions?

APC by Schneider Electric SMX1500RM2UC

$1,740.00
$1,186.99

RELATED PRODUCTS

Save $857.01
APC by Schneider Electric Schneider Electric APC - SRT192BP
Add to Cart The item has been added

APC by Schneider Electric SRT192BP

APC by Schneider Electric Schneider Electric APC - SRT192BP

192V lead acid rackmount battery pack designed to extend the runtime of compatible Smart-UPS SRT series uninterruptible power supplies

    In stock · Ships same business day Free shipping over $499
    $2,560.00 $1,702.99 Save $857.01
    The item has been added Add to quote
    $2,560.00 $1,702.99 Save $857.01
    Save $857.01 Add to cart Add to quote
    Save $141.01
    APC by Schneider Electric Schneider Electric AP9551 - Power
    Add to Cart The item has been added

    APC by Schneider Electric AP9551

    APC by Schneider Electric Schneider Electric AP9551 - Power

    14-outlet, 120V rack mount PDU from APC by Schneider Electric, designed to distribute power from a single NEMA L5-20P source across up to 14 devices

      In stock · Ships same business day Free shipping over $499
      $426.00 $284.99 Save $141.01
      The item has been added Add to quote
      $426.00 $284.99 Save $141.01
      Save $141.01 Add to cart Add to quote
      Save $671.01
      APC by Schneider Electric SMX1500RM2UCNC
      Add to Cart The item has been added

      APC by Schneider Electric SMX1500RM2UCNC

      APC by Schneider Electric SMX1500RM2UCNC

      1500VA/1000W rackmount Uninterruptible Power Supply (UPS) designed to provide clean, reliable battery backup and surge protection for critical IT

        Usually Ships in 2-3 Weeks Free shipping over $499
        $2,670.00 $1,998.99 Save $671.01
        The item has been added Add to quote
        $2,670.00 $1,998.99 Save $671.01
        Save $671.01 Add to cart Add to quote

        System Design, Deployment & Technical Support

        Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

        Fixed scope • Fixed price

        System Design Assistance

        • Get help validating product compatibility
        • Coverage requirements
        • Storage planning and deployment architecture before you buy.
        Request Design Help

        Deployment & Configuration Support

        • Access fixed-scope support for rollout planning
        • User setup guidance
        • Migration and system standardization across single-site or multi-site deployments
        View Support Services

        Guides, Tools & Calculators

        • PoE requirements
        • Storage retention
        • Camera selection and deployment methodology
        Open Technical Resources