Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: SMT1500RMI2UC
UPC: 731304333005
Condition: New
Write a Review 32% OFF

APC by Schneider Electric SMT1500RMI2UC - UPS - 2U - Line-interactive - 230 V - 1000WATT - 1500VA

APC by Schneider Electric SMT1500RMI2UC 1500VA 2U Rack-Mount Line-Interactive UPSOverviewThe APC by Schneider Electric SMT1500RMI2UC is a 1500VA / 100…

$1,670.00 $1,138.99 SAVE $531
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

APC by Schneider Electric SMT1500RMI2UC - UPS - 2U - Line-interactive - 230 V - 1000WATT - 1500VA

$1,670.00
$1,138.99

Overview

SKU: SMT1500RMI2UC
UPC: 731304333005
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric SMT1500RMI2UC 1500VA 2U Rack-Mount Line-Interactive UPS

Overview

The APC by Schneider Electric SMT1500RMI2UC is a 1500VA / 1000W line-interactive uninterruptible power supply built for 2U rack installations running on 230V infrastructure. Line-interactive topology means the unit continuously conditions incoming voltage — correcting sags and surges through its automatic voltage regulation (AVR) circuitry before power ever reaches your equipment — without switching to battery for every fluctuation. That distinction matters in environments where utility power is noisy but outages are infrequent: you extend battery life significantly compared to an online double-conversion unit cycling its batteries on every minor brownout.

At 1000W true output power, the SMT1500RMI2UC fits a single rack shelf of network-attached storage, a mid-range NVR with several drives spinning, or a small PoE switch stack serving an access-control or IP camera deployment. The 1500VA rating gives you enough headroom to handle the inrush current that accompanies equipment startup without tripping under load.

Key Features

  • 1500VA / 1000W Line-Interactive Topology: AVR corrects under- and over-voltage in real time without depleting the battery — useful in facilities where HVAC compressors or other heavy machinery cause frequent voltage sags. A double-conversion unit in the same scenario would drain its battery on every sag, shortening service intervals.
  • 2U Rack Form Factor: Fits any standard 19-inch rack in a 2U footprint, keeping your power protection co-located with the equipment it protects. Deploying it at the rack level (rather than relying on a remote floor UPS) shortens the protected circuit and reduces the chance of a cable fault between the UPS and the load.
  • 230V Input and Output (IEC 320 C14 Inlet): Designed for 230V mains — the standard in most of Europe, the Middle East, Africa, and parts of Asia-Pacific. The IEC 320 C14 input connector is a locking industrial-grade interface that mates with standard C13 power cords, reducing the risk of accidental disconnection in high-vibration or high-traffic equipment rooms.
  • 220V / 240V Input Tolerance: Accepts the full 220–240V band commonly found across different regional grid standards, so this unit installs without modification in facilities where nominal voltage drifts between those values depending on local utility tolerances.
  • Lead-Acid Battery Chemistry: Valve-regulated lead-acid (VRLA) batteries are maintenance-free under normal operating conditions and do not require watering or equalization cycles. They are also widely available for replacement, which matters when you're planning five-to-seven-year refresh cycles in a managed infrastructure environment.
  • 26.1 kg Installed Weight: At roughly 57.5 lbs, this unit is within single-person lift capacity for most rack installations but benefits from a two-person install or a rack-lift assist when mounting above chest height. Factor this into your rack load calculations — confirm your rack and floor ratings before stacking multiple units.

Integration and Compatibility

The SMT1500RMI2UC is part of the APC Smart-UPS line, which is supported by power protection management ecosystems including APC's PowerChute software for graceful server shutdown during extended outages. The IEC C14 input is compatible with standard rack PDU and C13 power-cord infrastructure, so it drops into existing network infrastructure racks without requiring custom cabling.

For security integrators deploying network video recorders, access control panels, or PoE switch stacks, the line-interactive design provides a practical middle ground between cost and protection level — better than a basic standby UPS for noise-sensitive recording equipment, at a lower acquisition and maintenance cost than a full online double-conversion unit. Pair this with a rack power distribution unit downstream to distribute the protected output across multiple loads cleanly.

If your deployment requires true online double-conversion isolation (for sensitive edge servers or high-value data processing nodes), consider a higher-tier Smart-UPS model in the same APC family that offers online topology at comparable rack density.

Frequently Asked Questions

Q: What is the difference between line-interactive and online double-conversion, and which does the SMT1500RMI2UC use?

A: The SMT1500RMI2UC uses line-interactive topology. In line-interactive mode, the unit corrects voltage sags and surges using its AVR circuit while the load runs directly from conditioned mains power — the battery only engages during a true outage. Online double-conversion runs all power through the inverter continuously, providing complete electrical isolation but consuming more energy and cycling batteries more frequently. Line-interactive is the practical choice for most rack deployments where outright isolation is not required.

Q: What input voltage and connector does the SMT1500RMI2UC require?

A: The unit accepts 220V, 230V, or 240V input via an IEC 320 C14 inlet. This is the standard two-prong-plus-earth locking connector used on most rack PDUs — a standard C13 power cord connects to it directly.

Q: How much true watt capacity does the SMT1500RMI2UC provide?

A: The rated output is 1000 watts (1500VA). When sizing your load, use the watt figure — not the VA rating — against your equipment's actual power draw. Keep total connected load below 80% of rated wattage (800W) for reliable runtime and thermal headroom.

Q: What type of battery does the SMT1500RMI2UC use, and is it user-replaceable?

A: It uses a lead-acid (VRLA) battery. APC Smart-UPS batteries are designed to be user-replaceable without powering down connected equipment (hot-swappable in most Smart-UPS 2U rack configurations), which reduces maintenance downtime in live environments.

Q: Is the SMT1500RMI2UC suitable for NVR or IP camera infrastructure?

A: Yes. At 1000W output, it comfortably supports a mid-range NVR with multiple drives, a managed PoE switch, and associated access-control or intercom hardware within a single rack. The line-interactive AVR is particularly valuable for NVR deployments where voltage fluctuations can cause drive errors or unexpected reboots on recording systems.

Q: What rack space does the SMT1500RMI2UC occupy?

A: The unit occupies 2U (two rack units) in a standard 19-inch equipment rack.

Jerry Tildsen
Jerry Tildsen

The spec I keep coming back to on the SMT1500RMI2UC is the 1000W true output rating against the 1500VA nameplate — that 0.67 power factor is honest engineering. Too many integrators size UPS capacity against VA and end up with a unit that throttles under real watt load. On a rack with a spinning-disk NVR drawing 180W, a managed PoE switch at 120W, and a pair of access control panels, you're at roughly 300–350W actual draw — well inside this unit's sustained output window, with plenty of headroom for inrush on power cycling.

Technical Highlights:

  • Line-Interactive AVR at 230V: Corrects the 220–240V input band continuously without battery draw — critical in older facilities where mains voltage wanders. Your NVR drives thank you: voltage irregularities are a leading cause of silent write errors on surveillance storage.
  • IEC 320 C14 Input Connector: Mates with standard C13 cords found on virtually every rack PDU in a 230V environment. No adapter, no custom cord — the SMT1500RMI2UC drops into an existing rack without a procurement detour.
  • 2U / 26.1 kg Form Factor: Dense enough to keep power protection local to the load, heavy enough to need a second set of hands above U24. Plan rack ballast distribution before finalizing chassis placement — bottom-loading a 26 kg unit keeps the center of gravity where you want it.

Deployment Considerations:

  • Size your actual connected watt load against the 1000W output ceiling — not the 1500VA figure. Budget 80% max (800W) for thermal and runtime margin; anything above that risks shortened battery service life under sustained load.
  • Lead-acid VRLA batteries degrade faster in high-ambient-temperature environments. If your equipment room runs above 25°C (77°F) consistently, expect reduced battery service life and plan replacement intervals accordingly — the rated capacity assumes a controlled thermal environment.

This unit is a strong fit for a single-rack physical security deployment: NVR, managed PoE switch, access control panel, and door hardware on one protected circuit in a 230V facility. It is not the right choice for a multi-rack compute cluster or any load requiring true online double-conversion isolation — step up to a higher-tier Smart-UPS model with online topology for those scenarios.

Specifications
Main Input Voltage: 230 V
Other Input Voltage: 220 V 240 V
Main Output Voltage: 230 V
Other Output Voltage: 220 V 240 V
Rated Power In W: 1000 W
Rated Power In W: 1000 W
Rated Power In Va: 1500 VA
Input Connection Type: IEC 320 C14
Input Connection Type: IEC 320 C14
Number Of Rack Unit: 2U
Number Of Rack Unit: 2U
Battery Type: Lead-acid battery
Battery Type: Lead-acid battery
Weight: 26.1 kg
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources