Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
Server Technology C2S39TS-YCBA2S444/C Smart Primary PRO2 PIPS Rack PDU
Overview
The C2S39TS-YCBA2S444/C is a Smart Primary PRO2 PIPS rack power distribution unit from Server Technology built around a 39-outlet mixed layout: 27x C13 outlets paired with 12x CX outlets. "PIPS" (Per Inlet Power Sensing) architecture means this is a monitored PDU — the kind of platform data center and server room teams reach for when they need outlet-level visibility instead of a dumb power strip bolted into the rack. If you're populating a cabinet with a mix of standard IT gear on C13 cords and equipment that needs the higher-retention CX connector, this outlet split is the actual reason to look at the C2S39TS-YCBA2S444/C rather than a single-connector-type PDU. Server Technology's Server Technology catalog runs several PRO2 variants at different outlet counts and phase configurations, so confirm this specific 39-outlet, dual-connector configuration matches your rack's cord inventory before ordering — swapping connector types after the fact isn't practical on a fixed-outlet PDU.
Key Features
- 39 total outlets: a high outlet count on a single PDU chassis means fewer PDUs per rack (or per pair of racks, on an A/B redundant setup) — fewer devices to mount, cable, and monitor, which matters when you're standardizing rack elevations across a row.
- 27x C13 outlets: C13 is the standard IEC connector on the overwhelming majority of servers, switches, and network gear — this is the bulk of your rack's power draw covered without adapters.
- 12x CX outlets: CX is Server Technology's locking-style connector option built for equipment where a standard C13 can walk out of the socket under vibration or cable weight — 12 of them on this unit means you don't have to split that load across a second PDU just to get locking outlets where you need them.
- Smart PRO2 platform (PIPS): Per Inlet Power Sensing gives you visibility at the inlet level, which is the baseline monitoring tier for teams that want to know total load on a PDU without paying for full per-outlet metering — useful for capacity planning across a row of cabinets.
- Mixed-connector design on one chassis: instead of running two separate single-type PDUs (one all-C13, one all-CX) to cover mixed equipment, this consolidates both connector types into one rack unit — one mounting footprint, one management IP if networked, one point of monitoring.
Integration & Compatibility
Outlet-count and connector-type decisions on a PDU are permanent for the life of the unit, so match the C2S39TS-YCBA2S444/C's 27x C13 / 12x CX split against your actual cord inventory before racking it. Pair it with rack-mount NVRs or other C13-corded infrastructure for the bulk of the load, and reserve the CX-connected outlets for equipment where a locking cord matters. If you're planning power distribution across a new cabinet buildout, review a PoE and power planning guide before finalizing outlet allocation — sizing the PDU to the rack's real draw up front avoids a mid-deployment swap. For broader context on how a PDU like this fits into a monitored rack alongside network switches and other rack infrastructure, plan connector counts against your actual device list rather than outlet totals alone — 39 outlets only helps if the connector mix lines up with what's plugging in.
Frequently Asked Questions
Q: How many outlets does the C2S39TS-YCBA2S444/C have?
A: 39 total: 27x C13 outlets and 12x CX outlets.
Q: What does PIPS mean on the C2S39TS-YCBA2S444/C?
A: PIPS stands for Per Inlet Power Sensing — the PDU monitors power draw at the inlet level as part of the Smart PRO2 platform.
Q: Can I use the C2S39TS-YCBA2S444/C with standard IEC C14 server power cords?
A: Yes for the 27 C13 outlets, which accept standard C14 cord ends. The 12 CX outlets require CX-compatible cords.
Q: Is the C2S39TS-YCBA2S444/C (often searched as C2S39TS YCBA2S444/C) new or refurbished?
A: Sourcing is factory-new, with no grey-market or parallel-import units.

The outlet split is what makes the C2S39TS-YCBA2S444/C worth a second look: 27x C13 plus 12x CX on one chassis means you're not running a separate locking-connector PDU alongside your standard one. I look at that split first because it tells me exactly what rack profile this unit was built for.
Technical Highlights:
- 39 total outlets: consolidates a mixed-equipment rack onto a single PDU instead of two, cutting one mounting slot and one monitoring point out of your cabinet plan.
- 27x C13 outlets: covers standard C14-corded servers and switches — the bulk of most racks — without adapters.
- 12x CX outlets: gives you locking-connector capacity for equipment prone to cord walk-out, without dedicating an entire second PDU to it.
Deployment Considerations:
- Count your CX-corded devices before ordering — 12 outlets is a fixed ceiling on this chassis, and there's no field conversion from C13 to CX.
- PIPS gives inlet-level draw, not per-outlet metering — if you need outlet-by-outlet load data for billing or granular alerting, confirm that's within scope for this PIPS tier before assuming it.
This is the right call for a rack running a majority of standard C13 IT gear with a smaller cluster of vibration-prone or high-value equipment on locking CX cords — a mixed-media cabinet, not a uniform server row. The C2S39TS-YCBA2S444/C exists specifically to serve that split without forcing a second PDU into the elevation.
Compare with similar
Server Technology Smart Primary PRO2 Pips - C2S39TS-YCBA2S444/C
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Server Technology products? Shop the full Server Technology catalog →
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology