Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
Server Technology C1S36TA-DQME2899/C PRO1 Smart Primary Power Distribution Unit
The Server Technology C1S36TA-DQME2899/C is a PRO1 Smart series primary power distribution unit built for 208V, 3-phase Delta electrical environments at 60A. It's part of the Configurable Hdot Alternate Phase line, positioned for data center and server room racks that need metered, IEC-terminated power distribution rather than a basic unmanaged strip. Evidence available for this SKU is limited to electrical ratings — treat this listing as a starting point for verifying fit against your rack's exact circuit requirements before ordering.
Key Specifications
- 208V 3-Phase Delta Input: Matches the three-phase Delta service common in commercial data center power plants, so it drops into existing 208V infrastructure without a step-down or phase-conversion requirement.
- 60A Amperage Rating: Sized for higher-density rack loads than a typical 20A or 30A strip — relevant when consolidating multiple servers or a blade chassis onto a single distribution point, but confirm your upstream breaker and cabling are rated to match before install.
- IEC Interface: Standard IEC output connectors mean compatibility with the IEC C13/C14-style power cords already in most rack-mount server and network gear, simplifying cable sourcing.
- Configurable Hdot Alternate Phase Design: The Hdot outlet arrangement alternates phases across output positions, a layout Server Technology uses on its PRO1 line to help balance load distribution across the three phases in the rack.
- PRO1 Smart Primary Designation: Identifies this unit as a primary (not secondary/expansion) PDU in Server Technology's Smart product family, intended as the main distribution point rather than a daisy-chained add-on.
Integration & Compatibility
The C1S36TA-DQME2899/C (often searched as C1S36TA DQME2899/C) is built for environments already wired for 208V 3-phase Delta service. Confirm your data center or server room's electrical plant matches this input before purchase — this is not a step-down or phase-converting device. Pair it with rack-mount servers, switches, and storage equipment using IEC-style power cords.
Frequently Asked Questions
Q: What electrical service does the C1S36TA-DQME2899/C require?
A: It requires 208V, 3-phase Delta input service rated to at least 60A.
Q: What output connector type does this PDU use?
A: IEC-style output connectors, compatible with standard IEC power cords used on rack-mount servers and networking gear.
Q: Is this a primary or expansion PDU?
A: It's a PRO1 Smart Primary unit, designed as the main distribution point rather than a secondary expansion unit.
Q: What does "Configurable Hdot Alt Phase" mean on this model?
A: It refers to Server Technology's Hdot outlet layout, which alternates phase assignment across output positions to help balance three-phase loads.

The C1S36TA-DQME2899/C is a 60A, 208V 3-phase Delta primary PDU — the electrical specs alone tell you most of what you need to know before you spec it into a rack.
Technical Highlights:
- 208V 3ph Delta @ 60A: This is a high-capacity primary feed, sized well above standard 20A/30A single-phase strips — appropriate for consolidated rack loads, not a small edge closet.
- IEC Output Interface: Standard IEC connectors mean no proprietary cord sourcing — your existing server and switch power cords should terminate directly.
- Hdot Alternate Phase Outlet Layout: Outlet phase assignment is staggered by design, which is the mechanism Server Technology's PRO1 line uses to help keep load balanced across all three phases instead of stacking draw onto one leg.
Deployment Considerations:
- Verify your data center's electrical plant is actually 208V 3-phase Delta before ordering — this unit isn't a phase converter or step-down device.
- Confirm upstream breaker and feeder cable sizing supports the full 60A rating before commissioning; a primary PDU at this amperage assumes dedicated circuit capacity.
The C1S36TA-DQME2899/C fits as the primary distribution point in a data center rack row already running 208V 3-phase Delta service and consolidating multiple high-draw servers onto IEC-corded power.
Compare with similar
Server Technology PRO1 Smart Primary Pips - C1S36TA-DQME2899/C
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Server Technology products? Shop the full Server Technology catalog →
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology