Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
Server Technology C2SG48TE-YCMFAM99 Switched Rack PDU
The Server Technology C2SG48TE-YCMFAM99 is a switched, per-outlet-metered Smart POPS Primary PRO2 power distribution unit built for data center and server room racks that need remote outlet control and branch-level current visibility. It takes a 208V, 30A feed through a NEMA L21-30P input plug and distributes it across a mixed outlet set rated for both C13/Cx and NEMA loads, with an 8.6kW total input power capacity. If you're standardizing rack power across a colo footprint or a multi-cabinet server room, the C2SG48TE-YCMFAM99 gives you outlet-level switching and current draw data without adding a separate monitoring appliance.
Overview
This is a vertical 0U-style unit at 80 inches tall, 2.2 inches wide, and 2.5 inches deep — designed to mount in the rear channel of a rack cabinet without consuming U-space that could otherwise hold servers or network gear. Input comes in at 208V, 50/60 Hz, through a NEMA L21-30P plug rated for 30A input current (24A rated continuous load), which lines up with standard 3-phase or split-phase data center whip circuits. A 10/100/1000 Mbps Ethernet port puts the unit on the management network for remote outlet switching and load monitoring.
Key Features
- 8.6kW Input Power Capacity: Sized for dense rack loads — servers, switches, and storage arrays drawing continuous power without tripping upstream breakers, which matters when you're filling a cabinet with 1U/2U compute.
- 30A NEMA L21-30P Input, 24A Rated Current: Matches common data center whip and PDU-feed circuits, so electricians sizing branch circuits have a known, documented draw to plan against.
- Per-Outlet C13/Cx/NEMA Ratings (≤12A–16A): Mixed outlet types on one strip mean you're not stuck running separate PDUs for IEC C14 server power cords and NEMA-plug equipment in the same rack.
- Branch Circuit Breaker Protection (≤16A, 10 kAIC): Each branch is individually breaker-protected with a 10,000A interrupt rating, so a downstream short trips a local breaker instead of taking down the whole PDU or upstream panel.
- Input/Output/Branch Current Accuracy (±1%/±1%/±3%): Metering precise enough to trust for capacity planning — you can size rack loads against real measured draw instead of nameplate estimates, which matters when you're trying to squeeze more gear onto an existing circuit.
- 10/100/1000 Mbps Ethernet Management: Gigabit-capable network port for remote outlet control and monitoring, so you're not walking the data center floor to power-cycle a hung server.
- Quiescent Power Draw Under 10W: The PDU's own overhead barely registers against an 8.6kW capacity budget — negligible parasitic load on the circuit you're metering.
- Wide Operating Temperature Range (32°F to 140°F): Rated for data center hot-aisle conditions well above typical server room ambient, giving headroom if cooling is marginal in a corner rack.
- Operating Elevation to 6,500ft: Usable at higher-altitude data center sites without derating concerns that lower-rated equipment runs into.
- UL 62368-1 / CSA C22.2 No. 62368-1 / FCC Part 15 Class A Certified: Covers US and Canadian safety compliance plus Class A EMC clearance for commercial IT equipment environments, which facilities and compliance teams will ask for during rack power sign-off.
Integration & Compatibility
The C2SG48TE-YCMFAM99 (often searched as C2SG48TE YCMFAM99) is built for standard rack-mount data center deployments where per-outlet switching and branch metering are part of the power management plan — pairing naturally with the network video recorders and switching gear typically racked alongside it. For facilities planning out circuit capacity across multiple cabinets, review a PoE and power planning guide before finalizing whip sizing, since branch breaker ratings here top out at 16A per circuit. It's a good fit alongside network switches and server hardware in the same rack, and belongs in the broader Server Technology catalog when standardizing PDU models across a data center footprint within the power distribution units category.
Frequently Asked Questions
Q: What input plug does the C2SG48TE-YCMFAM99 use?
A: It terminates in a NEMA L21-30P input plug rated for 30A at 208V, 50/60 Hz.
Q: How many outlets does the C2SG48TE-YCMFAM99 have?
A: It's a 48-outlet unit with mixed C13, Cx, and NEMA outlet ratings, each protected by individual branch circuit breakers rated up to 16A.
Q: Can I monitor outlet-level power draw remotely on the C2SG48TE-YCMFAM99?
A: Yes — it includes a 10/100/1000 Mbps Ethernet port with input, output, and branch current metering accurate to ±1%/±1%/±3% respectively.
Q: What's the operating temperature range for the C2SG48TE-YCMFAM99?
A: 32°F to 140°F (0°C to 60°C) with 8% to 90% RH non-condensing humidity, suitable for standard and hot-aisle data center environments.
Q: What certifications does the C2SG48TE-YCMFAM99 carry?
A: UL 62368-1, CSA C22.2 No. 62368-1, FCC Part 15 Class A, and CAN ICES-003 Class A.

The spec that jumps out on the C2SG48TE-YCMFAM99 is the branch current accuracy: ±3% at the branch level, tightening to ±1% on input and output metering. For a PDU carrying 8.6kW across 48 outlets, that's precise enough to actually trust for capacity planning instead of padding estimates with guesswork.
Technical Highlights:
- 208V/30A Input via NEMA L21-30P: Rated 24A continuous against a 30A plug rating — standard practice for NEC 80% continuous-load derating, so don't plan your circuit at the full 30A nameplate number.
- 10 kAIC Branch Breaker Rating: Each of the individually breakered branches (≤16A) interrupts up to 10,000A, which contains a downstream fault to that branch instead of nuisance-tripping the whole strip.
- Quiescent Draw Under 10W: Against an 8.6kW budget, the PDU's own overhead is a rounding error — essentially all your metered capacity goes to actual IT load.
Deployment Considerations:
- The 80-inch vertical form factor (2.2in x 2.5in footprint) is built for 0U rear-rail mounting — confirm rear channel clearance on the target cabinet before ordering, since this isn't a horizontal 1U/2U unit.
- Outlet ratings top out at 16A per branch even though total input capacity is 8.6kW — plan load distribution across branches rather than assuming any single outlet can carry a high-draw device near the branch ceiling.
This is the right PDU for a colo or enterprise data center rack standardizing on switched, per-outlet-metered power with gigabit Ethernet management — particularly racks mixing C13 server cords with NEMA-plug equipment on one strip, where the C2SG48TE-YCMFAM99's mixed outlet set avoids running a second PDU.
Compare with similar
Server Technology Smart Pops Primary PRO2 - C2SG48TE-YCMFAM99
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Server Technology products? Shop the full Server Technology catalog →
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology