Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
No Bots, Just Experts
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
Server Technology C2SG48TE-DFME2M99 48-Outlet Switched PRO2 Rack PDU
Overview
The Server Technology C2SG48TE-DFME2M99 is a vertical Switched PRO2 power distribution unit built for data center and network operations center racks that need granular, remote-controllable power at scale. It's a 0U vertical mount unit, 80 inches tall and only 2.2 inches wide by 2.5 inches deep, so it runs the full height of a standard rack cabinet without eating into usable rack unit space for servers, switches, or patch panels. Input is 208V at 50/60 Hz through a CS8365 3P+G 50A plug, rated for 40A continuous input current and 14.4 kW of total input power capacity — enough headroom for a densely populated server or network rack without derating concerns. If you're standardizing PDUs across a colocation footprint or building out a new server room from scratch, this unit fits the same architecture as other units in the Server Technology catalog, which simplifies spares planning and firmware management across a rack fleet.
Key Features
- 48 Switched Outlets (C13/Cx mix): Individually switched outlets rated up to 12A @ 208V L-L on C13 positions and up to 16A @ 208V L-L on Cx positions let you remotely cycle power to a hung server or misbehaving switch without a trip to the data hall — critical when the rack is in a remote colo or a locked cage.
- Branch Circuit Protection at 16A, 10 kAIC: Each branch circuit breaker is rated ≤16A with a 10 kAIC interrupt rating, isolating a fault to a single branch instead of tripping the whole PDU and taking down every device downstream.
- Gigabit Ethernet Management (10/100/1000 Mbps): Full gigabit connectivity means the PDU's web interface and SNMP polling won't bottleneck on a busy management VLAN, and it keeps pace with modern out-of-band network designs.
- RS-232 Serial + RJ-12 Link Port: Serial console access covers initial configuration or environments where IP connectivity to the management network isn't available yet, and the RJ-12 link port supports daisy-chaining additional PRO2 units under one network connection — fewer IP addresses to manage per rack row.
- Two Temperature Sensor Inputs: Two onboard ports for environmental probes give you rack-level thermal visibility (hot aisle creep, failed CRAC unit) without a separate environmental monitoring appliance.
- Broad Protocol Support: HTTP/HTTPS, TLSv1.2, SSHv2, Telnet, SNMPv2c/v3, IPv4/IPv6, LDAPv3/LDAPS, TACACS+, RADIUS, and FTP/SFTP cover encrypted management, centralized authentication (LDAP, TACACS+, RADIUS), and automated firmware or config transfer — this integrates into an existing enterprise AAA setup rather than forcing a standalone local-account model.
- Quiescent Power Draw Under 10W: The PDU's own overhead is negligible against a 14.4 kW capacity, so it isn't eating into the power budget you're allocating to actual IT load.
- Wide Operating Range — 0°C to 60°C, 8-90% RH Non-Condensing: The 60°C high-temperature rating means this unit tolerates hot aisle conditions or a marginally-cooled edge/telecom room where a standard-rated PDU would be out of spec.
- Storage Range to -30°C / 80°C: Relevant for spares kept in an unconditioned warehouse or shipped through extreme climates before installation.
- Rated to 6,500 ft Operating Elevation: Covers most continental US data center sites, including higher-altitude metros, without a derating conversation.
- UL 62368-1 / CSA C22.2 No. 62368-1 Safety Listing: North American safety certification relevant for insurance, AHJ inspection, and facilities compliance documentation.
- FCC Part 15 Subpart B Class A / CAN ICES-003 Class A EMC: Class A emissions certification appropriate for commercial and industrial environments, not residential.
Integration & Compatibility
The C2SG48TE-DFME2M99 (often searched as C2SG48TE DFME2M99) is designed to sit alongside standard 19-inch or 23-inch rack infrastructure as a 0U vertical PDU, freeing horizontal rack units for compute and network gear. Its SNMPv2c/v3 support means it drops into existing monitoring stacks (data center infrastructure management platforms, NMS polling) without a proprietary agent, and LDAPv3/LDAPS plus TACACS+/RADIUS support let it authenticate against the same directory and AAA infrastructure already governing switches and console servers in the rack. For facilities planning a multi-rack rollout, pair this unit's layout against your power distribution and PDU lineup to standardize outlet counts and input plug types across racks, and review a power and capacity planning guide before finalizing breaker and circuit assignments — 14.4 kW per PDU adds up fast across a full row.
Frequently Asked Questions
Q: What input plug and voltage does the C2SG48TE-DFME2M99 require?
A: It uses a CS8365 3P+G 50A plug on a 208V, 50/60 Hz circuit, rated for 40A input current and 14.4 kW input capacity.
Q: How many outlets does the C2SG48TE-DFME2M99 have and are they individually switched?
A: It has 48 outlets in a C13/Cx configuration, each individually switched, with C13 positions rated up to 12A @ 208V L-L and Cx positions up to 16A @ 208V L-L.
Q: Can I manage this PDU remotely over the network?
A: Yes. It includes 10/100/1000 Mbps Ethernet with HTTP/HTTPS, SSHv2, Telnet, SNMPv2c/v3, TLSv1.2, LDAPv3/LDAPS, TACACS+, and RADIUS support for remote outlet control and centralized authentication.
Q: What's the operating temperature range for the C2SG48TE-DFME2M99?
A: 0°C to 60°C (32°F to 140°F) at 8-90% RH non-condensing, with a high-temperature rating of 60°C.
Q: Does the C2SG48TE-DFME2M99 support environmental monitoring?
A: Yes, it has two temperature sensor inputs for connecting external probes to monitor rack-level conditions.
Q: What safety and EMC certifications does this unit carry?
A: UL 62368-1 and CSA C22.2 No. 62368-1 for safety, and FCC Part 15 Subpart B Class A plus CAN ICES-003 Class A for EMC.

When I spec a vertical PDU for a dense server rack, the input capacity is the first thing I check against the rack's actual load, and the C2SG48TE-DFME2M99 gives you 14.4 kW at 40A on a 208V CS8365 3P+G plug — that's a real number to build a circuit schedule around, not a marketing figure.
Technical Highlights:
- 48 individually switched outlets: C13 positions capped at 12A @ 208V L-L and Cx positions at 16A @ 208V L-L means you can remote-cycle a single hung device without touching neighboring outlets — I lean on this constantly for out-of-band recovery on locked cages.
- 10 kAIC branch breakers at ≤16A: That interrupt rating isolates a downstream fault to one branch circuit instead of dropping the whole PDU, which matters when 48 outlets' worth of gear share one unit.
- 0U footprint at 80in x 2.2in x 2.5in: Full rack-height vertical mount means zero horizontal RU consumed — every U stays available for compute, and 2.2 inches of width barely intrudes on cable channels.
Deployment Considerations:
- The CS8365 3P+G 50A input plug is a locking three-phase connector — confirm your PDU whip and receptacle are already provisioned for it before the unit shows up on site, since it's not a field-swappable IEC cord.
- Quiescent draw is under 10W, which is trivial against 14.4 kW capacity, but remember that figure is the PDU's own overhead — your actual usable IT load still needs to respect the 40A/16A branch limits after derating for continuous-load code requirements.
This is the right PDU for a colocation cage or NOC rack row standardizing on gigabit-managed, LDAP/RADIUS-authenticated power distribution — anywhere you need per-outlet remote control across 48 device connections without burning rack units to get it.
Compare with similar
Server Technology Smart Pops Primary PRO2 - C2SG48TE-DFME2M99
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Server Technology products? Shop the full Server Technology catalog →
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology